Preliminary development of anatomically realistic breast tumor models for microwave imaging

被引:0
作者
Pelicano, Ana Catarina [1 ]
Araujo, Nuno A. M. [2 ]
Conceicao, Raquel C. [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
[2] Univ Lisbon, Fac Ciencias, Ctr Fis Teor & Computac, P-1749016 Lisbon, Portugal
来源
2022 16TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP) | 2022年
关键词
breast cancer; tumor classification; morphological features; CANCER DETECTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, we present a preliminary study of three classifiers - Linear Discriminant Analysis (LDA), Support Vector Machines (SVMs) and k-Nearest Neighbors (kNN) - to differentiate between malignant and benign tumors extracted from Magnetic Resonance (MR) images, based on their morphological features. The dataset in this study comprises 24 tumors: 12 malignant and 12 benign. Twelve morphological features were initially considered for tumor classification. The Mann-Whitney test was employed for feature selection, and the performance of the classifiers was evaluated with accuracy, sensitivity, specificity, F1-score and Matthew's Correlation Coefficient (MCC) metrics. kNN (with k=6 and Chebyshev distance) outperformed the other classifiers with an accuracy, sensitivity, and specificity of 87.5%, 83.3% and 91.7%, respectively.
引用
收藏
页数:4
相关论文
共 28 条
  • [1] The advantages of the Matthews correlation coefficient (MCC) over F1 score and accuracy in binary classification evaluation
    Chicco, Davide
    Jurman, Giuseppe
    [J]. BMC GENOMICS, 2020, 21 (01)
  • [2] Classification of breast tumor models with a prototype microwave imaging system
    Conceicao, Raquel C.
    Medeiros, Hugo
    Godinho, Daniela M.
    O'Halloran, Martin
    Rodriguez-Herrera, Diego
    Flores-Tapia, Daniel
    Pistorius, Stephen
    [J]. MEDICAL PHYSICS, 2020, 47 (04) : 1860 - 1870
  • [3] D'Orsi C.J., 2013, Breast Imaging Reporting and Data SystemACR BI-RADS Atlas
  • [4] Drasco D., 2012, NEW J PHYS, V14
  • [5] On-Site Validation of a Microwave Breast Imaging System, before First Patient Study
    Fasoula, Angie
    Duchesne, Luc
    Cano, Julio Daniel Gil
    Lawrence, Peter
    Robin, Guillaume
    Bernard, Jean-Gael
    [J]. DIAGNOSTICS, 2018, 8 (03)
  • [6] Confocal microwave Imaging for breast cancer detection: Localization of tumors in three dimensions
    Fear, EC
    Li, X
    Hagness, SC
    Stuchly, MA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (08) : 812 - 822
  • [7] Microwave Breast Imaging Using a Dry Setup
    Felicio, Joao M.
    Bioucas-Dias, Jose M.
    Costa, Jorge R.
    Fernandes, Carlos A.
    [J]. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 167 - 180
  • [8] Real time breast microwave radar image reconstruction using circular holography: A study of experimental feasibility
    Flores-Tapia, Daniel
    Pistorius, Stephen
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5420 - 5431
  • [9] Gibbons J. D. C., 2011, NONPARAMETRIC STAT I, V5th
  • [10] Gonzalez R.C., 2002, DIGITAL IMAGE PROCES