摘要
An analysis is presented of the relative magnitudes of factors affecting the specific loadability (W mm(-2) K-1) of liquid metal anode X-ray sources (LIMAX). These factors are to a certain extent analogous to those, such as focus width, focus-anode relative sweep velocity and the anode thermal conductivity, of importance in solid-state (e.g. rotating anode) X-ray tubes. It is shown that in general, convection cooling of the electron window by the liquid metal stream represents the least efficient thermal transport process in LIMAX. As the energy deposited in the electron window through inelastic electron scattering is approximately inversely proportional to electron energy, the power loadability of a LIMAX source operated under constant conditions scales to first approximation with the square of the tube potential. This power-voltage scaling law of liquid metal anode X-ray sources is without analogue in solid-state X-ray sources. A summary is presented of potential applications of high continuous power X-ray sources operating in the high-voltage region of several 100 kV. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [41] Measuring equipment for controlling the anode current during training and testing of the X-ray tubes
    Vasquez, N. O. Perez
    Kostrin, D. K.
    Uhov, A. A.
    3RD INTERNATIONAL CONFERENCE ON X-RAY TECHNIQUE, 2017, 808
  • [42] SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes
    Poludniowski, G.
    Landry, G.
    DeBlois, F.
    Evans, P. M.
    Verhaegen, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19): : N433 - N438
  • [43] Experimental observation and numerical simulation of spectra of solid-anode X-ray tubes
    P. G. Volkov
    S. I. Korobeinikov
    V. I. Nikolaev
    V. B. Sovkov
    Journal of Analytical Chemistry, 2016, 71 : 471 - 475
  • [44] Application of a Vibration Diagnosis Method for Monitoring Quality of Rotating Anode X-Ray Tubes
    Lobanov I.S.
    Stolyarov V.N.
    Stolyarov I.N.
    Biomedical Engineering, 2012, 46 (3) : 124 - 126
  • [45] Experimental observation and numerical simulation of spectra of solid-anode X-ray tubes
    Volkov, P. G.
    Korobeinikov, S. I.
    Nikolaev, V. I.
    Sovkov, V. B.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (05) : 471 - 475
  • [46] Qualitative measurements of low voltage shock-proof x-ray tubes
    Reinhard, MC
    ARCHIVES OF DERMATOLOGY AND SYPHILOLOGY, 1940, 41 (04): : 718 - 721
  • [47] X-ray tubes for projection X-ray radiography of new generation
    Podimsky, A. A.
    Potrakhov, N. N.
    3RD INTERNATIONAL CONFERENCE ON X-RAY TECHNIQUE, 2017, 808
  • [48] THE INPUT POWER LIMIT OF THE CYLINDRICAL ROTATING ANODE OF A X-RAY TUBE
    ISHIMURA, T
    SHIRAIWA, T
    SAWADA, M
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1957, 12 (10) : 1064 - 1070
  • [49] A Low Ripple Voltage Multiplier for X-ray Power Supply
    Iqbal, Shahid
    Besar, Rosli
    Venkataseshiah, C.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1451 - 1455
  • [50] THERMAL analysis of high power x-ray target: scaling effects
    Zhang, Xi
    Robinson, Vance S.
    Raber, Thomas R.
    Frontera, Mark
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS IV, 2015, 9590