A power-voltage scaling law for liquid anode X-ray tubes

被引:1
|
作者
Harding, G [1 ]
机构
[1] Yxlon Int Secur, D-22419 Hamburg, Germany
关键词
X-ray source; liquid metal; cooling; scatter technique;
D O I
10.1016/j.radphyschem.2004.08.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An analysis is presented of the relative magnitudes of factors affecting the specific loadability (W mm(-2) K-1) of liquid metal anode X-ray sources (LIMAX). These factors are to a certain extent analogous to those, such as focus width, focus-anode relative sweep velocity and the anode thermal conductivity, of importance in solid-state (e.g. rotating anode) X-ray tubes. It is shown that in general, convection cooling of the electron window by the liquid metal stream represents the least efficient thermal transport process in LIMAX. As the energy deposited in the electron window through inelastic electron scattering is approximately inversely proportional to electron energy, the power loadability of a LIMAX source operated under constant conditions scales to first approximation with the square of the tube potential. This power-voltage scaling law of liquid metal anode X-ray sources is without analogue in solid-state X-ray sources. A summary is presented of potential applications of high continuous power X-ray sources operating in the high-voltage region of several 100 kV. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [1] Liquid metal anode X-ray tubes and their potential for high continuous power operation
    Harding, G
    Thran, A
    David, B
    RADIATION PHYSICS AND CHEMISTRY, 2003, 67 (01) : 7 - 14
  • [2] Liquid metal anode x-ray tubes - interesting, but are they useful?
    Harding, G
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS VI, 2004, 5541 : 37 - 46
  • [3] Comparison of high voltage X-ray tubes
    Taylor, LS
    Singer, G
    Stoneburner, CF
    BUREAU OF STANDARDS JOURNAL OF RESEARCH, 1933, 11 (1/3): : 341 - 351
  • [4] X-RAY TUBES WITH GOLD AND PALLADIUM ANODE MIRRORS
    DONETS, YT
    IOFFE, YK
    KAGAN, RN
    LEGONKOV.NN
    NIKOLAEN.GM
    FRIDMAN, EM
    INDUSTRIAL LABORATORY, 1969, 35 (02): : 297 - &
  • [5] Resonant Frequency of Rotating Anode X-Ray Tubes
    Shin, M.
    Lillaney, P.
    Hinshaw, W.
    Fahrig, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3622 - 3622
  • [6] High voltage cathode ray and X-ray tubes and their operation
    Coolidge, W. A.
    Dempster, L. E.
    Tanis, H. E., Jr.
    PHYSICS-A JOURNAL OF GENERAL AND APPLIED PHYSICS, 1931, 1 (01): : 230 - 244
  • [7] Liquid metal anode x-ray tube
    David, B
    Barschdorf, H
    Doormann, V
    Eckart, R
    Harding, G
    Schlomka, JP
    Thran, A
    Bachmann, P
    Flisikowski, P
    LASER-GENERATED AND OTHER LABORATORY X-RAY AND EUV SOURCES, OPTICS, AND APPLICATIONS, 2003, 5196 : 432 - 443
  • [8] COMPARISON OF POWER SUPPLIES AND X-RAY TUBES FOR X-RAY SPECTROCHEMICAL ANALYSIS
    SPIELBERG, N
    MACK, M
    SPECTROCHIMICA ACTA, 1958, 12 (04): : 382 - 382
  • [9] A voltage regulator for gas discharge x-ray tubes
    Haworth, FE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1929, 19 (02): : 79 - 80
  • [10] Microfocus X-ray tubes with increased power
    Podimsky, A. A.
    Potrakhov, N. N.
    Staroverov, N. Y.
    Klonov, V. V.
    Larionov, I. A.
    24TH INTERNATIONAL CONFERENCE ON VACUUM TECHNIQUE AND TECHNOLOGY, 2017, 872