Contrast of Z-Pinch X-Ray Yield Measure Technique

被引:1
作者
Li Mo [1 ]
Wang Liang-ping [1 ]
Sheng Liang [1 ]
Lu Yi [1 ]
机构
[1] Northwest Inst Nucl Technol, Key State Lab Simulat & Effect Intense Pulse Radi, Xian 710024, Peoples R China
关键词
Resistive bolometer; Scintillant detection system; X-ray yield measurement; Z-pinch; plasma; DIAGNOSTICS;
D O I
10.3964/j.issn.1000-0593(2015)03-0829-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Resistive bolometer and scintillant detection system are two mainly Z-pinch X-ray yield measure techniques which are based on different diagnostic principles. Contrasting the results from two methods can help with increasing precision of X-ray yield measurement. Experiments with different load material and shape were carried out on the "Qiang-Guang-I" facility. For Al wire arrays, X-ray yields measured by the two techniques were largely consistent. However, for insulating coating W wire arrays, X-ray yields taken from bolometer changed with load parameters while data from scintillant detection system hardly changed. Simulation and analysis draw conclusions as follows: (1) Scintillant detection system is much more sensitive to X-ray photons with low energy and its spectral response is wider than the resistive bolometer. Thus, results from the former method are always larger than the latter. (2) The responses of the two systems are both flat to Al plasma radiation. Thus, their results are consistent for Al wire array loads. (3) Radiation form planar W wire arrays is mainly composed of sub-keV soft X-ray. X-ray yields measured by the bolometer is supposed to be accurate because of the nickel foil can absorb almost all the soft X-ray. (4) By contrast, using planar W wire arrays, data from scintillant detection system hardly change with load parameters. A possible explanation is that while the distance between wires increases, plasma temperature at stagnation reduces and spectra moves toward the soft X-ray region. Scintillator is much more sensitive to the soft X-ray below 200 eV. Thus, although the total X-ray yield reduces with large diameter load, signal from the scintillant detection system is almost the same. (5) Both Techniques affected by electron beams produced by the loads.
引用
收藏
页码:829 / 833
页数:5
相关论文
共 13 条
[1]   Development and characterization of a Z-pinch-driven hohlraum high-yield inertial confinement fusion target concept [J].
Cuneo, ME ;
Vesey, RA ;
Porter, JL ;
Chandler, GA ;
Fehl, DL ;
Gilliland, TL ;
Hanson, DL ;
McGurn, JS ;
Reynolds, PG ;
Ruggles, LE ;
Seamen, H ;
Spielman, RB ;
Struve, KW ;
Stygar, WA ;
Simpson, WW ;
Torres, JA ;
Wenger, DF ;
Hammer, JH ;
Rambo, PW ;
Peterson, DL ;
Idzorek, GC .
PHYSICS OF PLASMAS, 2001, 8 (05) :2257-2267
[2]  
[蒋世伦 JIANG Shilun], 2006, [原子能科学技术, Atomic Energy Science and Technology], V40, P96
[3]   Advanced x-ray and extreme ultraviolet diagnostics and first applications to x-pinch plasma experiments at the Nevada Terawatt Facility [J].
Kantsyrev, V ;
Bauer, B ;
Shlyaptseva, A ;
Fedin, D ;
Hansen, S ;
Presura, R ;
Batie, S ;
Brinsmead, W ;
Faretto, H ;
Le Galloudec, B ;
Oxner, A ;
Chamberlain, D ;
Ouart, N ;
Jones, A ;
LeBeau, H ;
Gharaibeh, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :663-666
[4]  
Li Mo, 2013, High Power Laser and Particle Beams, V25, P2142, DOI 10.3788/HPLPB20132508.2142
[5]   Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility [J].
Li Mo ;
Wu Jian ;
Wang Liang-Ping ;
Wu Gang ;
Han Juan-Juan ;
Guo Ning ;
Qiu Meng-Tong .
CHINESE PHYSICS B, 2012, 21 (12)
[6]  
Matzen M K, 1999, PLASMA PHYS CONTROL, V41, P287
[7]   Spectroscopy and implosion dynamics of low wire number nested arrays on the 1 MA COBRA generator [J].
Safronova, A. S. ;
Kantsyrev, V. L. ;
Esaulov, A. A. ;
Ouart, N. D. ;
Yilmaz, M. F. ;
Williamson, K. M. ;
Shrestha, I. ;
Osborne, G. C. ;
Greenly, J. B. ;
Chandler, K. M. ;
McBride, R. D. ;
Chalenski, D. A. ;
Hammer, D. A. ;
Kusse, B. R. ;
LePell, P. D. .
PHYSICS OF PLASMAS, 2008, 15 (03)
[8]   Initiation of aluminum wire array on the 1-MA ZEBRA accelerator and its effect on ablation dynamics and x-ray yield [J].
Sarkisov, G. S. ;
Rosenthal, S. E. ;
Struve, K. W. ;
Cowan, T. E. ;
Presura, R. ;
Astanovitskiy, A. L. ;
Haboub, A. ;
Morozov, A. .
PHYSICS OF PLASMAS, 2007, 14 (11)
[9]   Study of Electron Beams in Wire Arrays at 1-MA Z-Pinch Generators [J].
Shrestha, Ishor ;
Kantsyrev, Victor L. ;
Safronova, Alla S. ;
Esaulov, Andrey A. ;
Williamson, Kenneth M. ;
Ouart, Nicholas D. ;
Osborne, Glenn C. ;
Weller, Michael E. ;
Yilmaz, M. Fatih .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (04) :658-666
[10]   DIAMOND PHOTOCONDUCTING DETECTORS AS HIGH-POWER Z-PINCH DIAGNOSTICS (INVITED) [J].
SPIELMAN, RB .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01) :867-870