Intraoperative forced air-warming during cesarean delivery under spinal anesthesia does not prevent maternal hypothermia

被引:95
作者
Butwick, Alexander J. [1 ]
Lipman, Steven S. [1 ]
Carvalho, Brendan [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Anesthesia, Stanford, CA 94305 USA
关键词
D O I
10.1213/01.ane.0000286167.96410.27
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Prewarming and intraoperative warming with forced air-warming systems prevent perioperative hypothermia and shivering in patients undergoing elective cesarean delivery with epidural anesthesia. We tested the hypothesis that intraoperative lower body forced air-warming prevents hypothermia in patients undergoing elective cesarean delivery with spinal anesthesia. METHODS: Thirty healthy patients undergoing cesarean delivery with spinal anesthesia were randomly assigned to forced air-warming or control groups (identical cover applied with forced air-warming unit switched off). A blinded investigator assessed oral temperature, shivering, and thermal comfort scores at 1.5-min intervals until discharge from the postanesthetic care unit. Umbilical cord blood gases and Apgar scores were also measured after delivery. RESULTS: The maximum core temperature changes were similar in the two groups (-1.3 degrees C +/- 0.4 degrees C vs -1.3 degrees C +/- 0.3 degrees C for the forced air-warming group and control group, respectively; P = 0.8). Core hypothermia (<= 35.5 degrees C) occurred in 8 of 15 patients receiving forced air-warming and in 10 of 15 unwarmed patients (P = 0.5). The incidence and severity of shivering did not significantly differ between groups. Umbilical cord blood gases and Apgar scores were similar in both groups (P = NS). CONCLUSIONS: We conclude that intraoperative lower body forced air-warming does not prevent intraoperative hypothermia or shivering in women undergoing elective cesarean delivery with spinal anesthesia. (Anesth Analg 2007;105:1413-9)
引用
收藏
页码:1413 / 1419
页数:7
相关论文
共 30 条
[1]   Effect of postoperative skin-surface warming on oxygen consumption and the shivering threshold [J].
Alfonsi, P ;
Nourredine, KEA ;
Adam, F ;
Chauvin, M ;
Sessler, DI .
ANAESTHESIA, 2003, 58 (12) :1228-1234
[2]   Comparison of forced-air warming systems with upper body blankets using a copper manikin of the human body [J].
Bräuer, A ;
English, MJM ;
Steinmetz, N ;
Lorenz, N ;
Perl, T ;
Braun, U ;
Weyland, W .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (08) :965-972
[3]   Comparison of forced-air warming systems with lower body blankets using a copper manikin of the human body [J].
Bräuer, A ;
English, MJM ;
Lorenz, N ;
Steinmetz, N ;
Perl, T ;
Braun, U ;
Weyland, W .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2003, 47 (01) :58-64
[4]   Obstetric anesthesia workforce survey - Twenty-year update [J].
Bucklin, BA ;
Hawkins, JL ;
Anderson, JR ;
Ullrich, FA .
ANESTHESIOLOGY, 2005, 103 (03) :645-653
[5]  
CAMUS Y, 1993, ANESTH ANALG, V77, P995
[6]   Perioperative shivering - Physiology and pharmacology [J].
De Witte, J ;
Sessler, DI .
ANESTHESIOLOGY, 2002, 96 (02) :467-484
[7]   EPIDURAL-ANESTHESIA INCREASES APPARENT LEG TEMPERATURE AND DECREASES THE SHIVERING THRESHOLD [J].
EMERICK, TH ;
OZAKI, M ;
SESSLER, DI ;
WALTERS, K ;
SCHROEDER, M .
ANESTHESIOLOGY, 1994, 81 (02) :289-298
[8]   Comparison of the effects of intrathecal morphine and pethidine on shivering after Caesarean delivery under combined-spinal epidural anaesthesia [J].
Hong, JY ;
Lee, IH .
ANAESTHESIA, 2005, 60 (12) :1168-1172
[9]   Active warming during cesarean delivery [J].
Horn, EP ;
Schroeder, F ;
Gottschalk, A ;
Sessler, DI ;
Hiltmeyer, N ;
Standl, T ;
Schulte, J .
ANESTHESIA AND ANALGESIA, 2002, 94 (02) :409-414
[10]   A randomised double-blind controlled study evaluating the hypothermic effect of 150 μg morphine during spinal anaesthesia for Caesarean section [J].
Hui, CK ;
Huang, CH ;
Lin, CJ ;
Lau, HP ;
Chan, WH ;
Yeh, HM .
ANAESTHESIA, 2006, 61 (01) :29-31