Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

被引:8
作者
Annoni, Andrea Daniele [1 ]
Mancini, Maria E. [1 ]
Andreini, Daniele [1 ,2 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Nobili, Enrica [1 ]
Guglielmo, Marco [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via C Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
CT angiography; dose reduction; ECG gated scan protocols; contrast agents; thoracic aorta; ROW CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGE-QUALITY; IODINE CONCENTRATION; MULTIDETECTOR CT; CHEST CT; ENHANCEMENT; REDUCTION; MDCT; KV;
D O I
10.1111/1754-9485.12608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionMultidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. MethodsTwo-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100Kvp tube voltage), Group C (Iomeprol 400 and 80Kvp tube voltage) and Group D (Iomeprol 400 and 100Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. ResultsNo significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80kV versus groups using 100kV but without differences in terms of image quality. ED was significantly lower in groups with 80kV. ConclusionsMultidetector Computed Tomography Angiography protocols using 80kV and low concentration contrast media are feasible without need of tailored injection protocols.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 26 条
  • [1] Abbara Suhny, 2007, J Cardiovasc Comput Tomogr, V1, P40, DOI 10.1016/j.jcct.2007.04.003
  • [2] Contrast Enhancement in Chest Multidetector Computed Tomography: Intraindividual Comparison of 300 mg/ml versus 400 mg/ml Iodinated Contrast Medium
    Behrendt, Florian F.
    Plumhans, Cedric
    Keil, Sebastian
    Muehlenbruch, Georg
    Das, Marco
    Seidensticker, Peter
    Mutscher, Christina
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (02) : 144 - 149
  • [3] Cardiac dual-source computed tomography - Effect of body mass index on image quality and diagnostic accuracy
    Brodoefel, Harald
    Tsiflikas, Ilias
    Burgstahler, Christof
    Reimann, Anja
    Thomas, Christoph
    Schroeder, Stephen
    Kopp, Andreas F.
    Claussen, Claus D.
    Heuschmid, Martin
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 712 - 718
  • [4] CT Angiography of the Thoracic Aorta
    Chung, Jonathan H.
    Ghoshhajra, Brian B.
    Rojas, Carlos A.
    Dave, Bhavika R.
    Abbara, Suhny
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (02) : 249 - +
  • [5] Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology
    Erbel, R
    Alfonso, F
    Boileau, C
    Dirsch, O
    Eber, B
    Haverich, A
    Rakowski, H
    Struyven, J
    Radegran, K
    Sechtem, U
    Taylor, J
    Zollikofer, C
    Klein, WW
    Mulder, B
    Providencia, LA
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (18) : 1642 - 1681
  • [6] 80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL)
    Faggioni, Lorenzo
    Neri, Emanuele
    Sbragia, Paola
    Pascale, Rachele
    D'Errico, Luigia
    Caramella, Davide
    Bartolozzi, Carlo
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1220 - 1225
  • [7] A workshop on quality criteria for computed tomography held in Arhus, Denmark, November 1998
    Geleijns, J
    Golding, S
    Menzel, HG
    Schibilla, H
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (03) : 544 - 545
  • [8] Low-Dose Multidetector CT Angiography in the Evaluation of Infrarenal Aorta and Peripheral Arterial Occlusive Disease
    Iezzi, Roberto
    Santoro, Marco
    Marano, Riccardo
    Di Stasi, Carmine
    Dattesi, Roberta
    Kirchin, Miles
    Tinelli, Giovanni
    Snider, Francesco
    Bonomo, Lorenzo
    [J]. RADIOLOGY, 2012, 263 (01) : 287 - 298
  • [9] 64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV
    Jun, Bo Ram
    Yong, Hwan Seok
    Kang, Eun-Young
    Woo, Ok Hee
    Choi, Eun Jung
    [J]. ACTA RADIOLOGICA, 2012, 53 (10) : 1099 - 1106
  • [10] Technical approaches to the optimisation of CT
    Kalender, Willi A.
    Buchenau, Stefanie
    Deak, Paul
    Kellermeier, Markus
    Langner, Oliver
    van Straten, Marcel
    Vollmar, Sabrina
    Wilharm, Sylvia
    [J]. PHYSICA MEDICA, 2008, 24 (02) : 71 - 79