The effects of prosthetic humeral head shape on glenohumeral joint kinematics during humeral axial rotation in total shoulder arthroplasty

被引:15
作者
Jun, Bong Jae [1 ,2 ]
Lee, Thay Q. [3 ]
McGarry, Michelle H. [3 ]
Quigley, Ryan J. [3 ]
Shin, Sang Jin [4 ]
Iannotti, Joseph P. [2 ]
机构
[1] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Cleveland Clin, Dept Orthoped Surg, Cleveland, OH 44106 USA
[3] VA Long Beach Healthcare Syst, Orthopaed Biomech Lab, Long Beach, CA USA
[4] Ewha Womans Univ, Dept Orthoped Surg, Seoul, South Korea
关键词
Humeral head shape; conformity; kinematics; translation; center of rotation; total shoulder arthroplasty; ARTICULAR CONFORMITY; SURGICAL TECHNIQUE; PROXIMAL HUMERUS; GEOMETRY; DESIGN; MOTION; TRANSLATIONS; STABILITY; COMPONENT; CADAVERA;
D O I
10.1016/j.jse.2015.11.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A non-spherical humeral head has been shown to influence kinematics and stability of the glenohumeral joint; yet, most prosthetic humeral head components are designed to be a perfect sphere. The effect of humeral head shape on prosthetic joint kinematics after total shoulder arthroplasty is not well understood. We hypothesized that prosthetic joint kinematics during humeral axial rotation is dependent on humeral head shape, regardless of joint conformity. Methods: Four prosthetic configurations were investigated using a spherical and a non-spherical prosthetic humeral head articulated with a conforming and a non-conforming glenoid component. Testing was performed in the coronal, scapular, and forward flexion plane at 0 degrees, 30 degrees, and 60 degrees of abduction. Prosthetic joint kinematics was measured in 10 degrees intervals during a 100 degrees arc of humeral axial rotation. Glenohumeral translation patterns, net glenohumeral translation, and averaged glenohumeral translation were compared for each of 4 configurations. Results: Non-spherical head configurations increased the net glenohumeral translation during humeral axial rotation in multiple test positions compared with spherical head configurations (P < .05). Spherical head configurations resulted in a relatively small amount of glenohumeral translation, less than 2 mm. The radius of curvature of the glenoid component alone did not affect the net glenohumeral translation within each of the 2 head groups (P > .05). Conclusion: During humeral axial rotation, the non-spherical humeral head shape contributes to increased glenohumeral translation during humeral axial rotation. However, the spherical head shape does not show significant glenohumeral translation during humeral axial rotation, regardless of glenoid conformity. (C) 2016
引用
收藏
页码:1084 / 1093
页数:10
相关论文
共 27 条
[1]   The three-dimensional geometry of the proximal humerus - Implications for surgical technique and prosthetic design [J].
Boileau, P ;
Walch, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :857-865
[2]   TRANSLATION OF THE HUMERAL HEAD ON THE GLENOID WITH PASSIVE GLENOHUMERAL MOTION [J].
HARRYMAN, DT ;
SIDLES, JA ;
CLARK, JM ;
MCQUADE, KJ ;
GIBB, TD ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (09) :1334-1343
[3]   THE EFFECT OF ARTICULAR CONFORMITY AND THE SIZE OF THE HUMERAL HEAD COMPONENT ON LAXITY AND MOTION AFTER GLENOHUMERAL ARTHROPLASTY - A STUDY IN CADAVERA [J].
HARRYMAN, DT ;
SIDLES, JA ;
HARRIS, SL ;
LIPPITT, SB ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (04) :555-563
[4]   Geometry of the proximal humerus and implications for prosthetic design [J].
Hertel, R ;
Knothe, U ;
Ballmer, FT .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (04) :331-338
[5]   NORMAL AND ABNORMAL MECHANICS OF THE GLENOHUMERAL JOINT IN THE HORIZONTAL PLANE [J].
HOWELL, SM ;
GALINAT, BJ ;
RENZI, AJ ;
MARONE, PJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :227-232
[6]   THE NORMAL GLENOHUMERAL RELATIONSHIPS - AN ANATOMICAL STUDY OF 140 SHOULDERS [J].
IANNOTTI, JP ;
GABRIEL, JP ;
SCHNECK, SL ;
EVANS, BG ;
MISRA, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (04) :491-500
[7]   Prosthetic positioning in total shoulder arthroplasty [J].
Iannotti, JP ;
Spencer, EE ;
Winfer, U ;
Deffenbaugh, D ;
Williams, G .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :111S-121S
[8]   The effects of prosthetic humeral head shape on glenohumeral joint kinematics: a comparison of non-spherical and spherical prosthetic heads to the native humeral head [J].
Jun, Bong Jae ;
Iannotti, Joseph P. ;
McGarry, Michelle H. ;
Yoo, Jae Chul ;
Quigley, Ryan J. ;
Lee, Thay Q. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (10) :1423-1432
[9]   Kinematics of the glenohumeral joint: Influences of muscle forces, ligamentous constraints, and articular geometry [J].
Karduna, AR ;
Williams, GR ;
Williams, JL ;
Iannotti, JP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (06) :986-993
[10]   Joint stability after total shoulder arthroplasty in a cadaver model [J].
Karduna, AR ;
Williams, GR ;
Williams, JL ;
Iannotti, JP .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1997, 6 (06) :506-511