Construction of a highly sensitive immunosensor based on antibody immunoglobulin G/3-(trimethoxysilyl) propylamine/graphene oxide for antigen-specific immunoglobulin G detection

被引:6
作者
Amini, Nader [1 ]
Shamsipur, Mojtaba [2 ]
Naderi, Kazhal [3 ]
Maleki, Afshin [1 ]
机构
[1] Kurdistan Univ Med Sci, Environm Hlth Res Ctr, Res Inst Hlth Dev, Sanandaj, Iran
[2] Razi Univ, Dept Analyt Chem, Kermanshah, Iran
[3] Kurdistan Univ Med Sci, Vice Chancellor Food & Drug, Sanandaj, Iran
关键词
Immunosensor; Antibody-antigen; 3(trimethoxysilyl) propylamine; Electrochemical impedance spectroscopy; NATRIURETIC PEPTIDE;
D O I
10.1016/j.microc.2022.107218
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study is to develop an immunosensor that has the ability to detect antigen G with properties such as very low detection of limit, remarkable with no bifunctional crosslinking species and excellent activity at physiological pH values. Immunoglobulin G (IgG) is found in all body fluids. When a specific bond occurs be-tween the anti-immunoglobulin G and the immunoglobulin G (anti-IgG), the result is activation of the reaction against viral and bacterial diseases. For detection and determination of antibody-antigen (Rabbit IgG-AntiRabbit IgG) interactions, a novel electrochemical immunosensor based on antibody immunoglobulin G/3-(trimethoxysilyl)propylamine/graphene oxide/glassy carbon (Ab/TMSPA/GO/GCE) was fabricated by using of carboxylic groups (-COOH) on graphene oxide (GO) and by exploiting 3-(trimethoxysilyl)propylamine (TMSPA) to covalently conjugate antibody molecules. For characterization of the modification process of the surface of glassy carbon electrode(GCE), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used. The change of impedance response was used for the monitoring of the interactions of antibody with different concentrations of antigen. Based on the results obtained, with increasing concentrations of antigen, the electron transfer resistance increased. The limit of detection (DL) and linear range 400 ng mL(-1) and 2-1500 mu g mL(-1) were obtained.
引用
收藏
页数:8
相关论文
共 24 条
  • [11] Impedimetric thrombin aptasensor based on chemically modified graphenes
    Loo, Adeline Huiling
    Bonanni, Alessandra
    Pumera, Martin
    [J]. NANOSCALE, 2012, 4 (01) : 143 - 147
  • [12] Label-free electrochemical impedance spectroscopy biosensor for the determination of human immunoglobulin G
    Qi, Honglan
    Wang, Chen
    Cheng, Ning
    [J]. MICROCHIMICA ACTA, 2010, 170 (1-2) : 33 - 38
  • [13] Rezaee Majid Asiabanha, 2017, J Immunoassay Immunochem, V38, P72, DOI 10.1080/15321819.2016.1216444
  • [14] Graphene oxide for electrochemical sensing applications
    Roy, Soumyendu
    Soin, Navneet
    Bajpai, Reeti
    Misra, D. S.
    McLaughlin, James A.
    Roy, Susanta Sinha
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (38) : 14725 - 14731
  • [15] Radioimmunoassay for N-terminal probrain natriuretic peptide in human plasma
    Schulz, H
    Langvik, TÅ
    Sagen, EL
    Smith, J
    Ahmadi, N
    Hall, C
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2001, 61 (01) : 33 - 42
  • [16] Label-Free Electrochemical Immunosensor Based on a Functionalized Ionic Liquid and Helical Carbon Nanotubes for the Determination of Cardiac Troponin I
    Shen, Qihui
    Liu, Man
    Lu, Yang
    Zhang, Dawei
    Cheng, Zhenyu
    Liu, Yan
    Gao, Huajing
    Jin, Zhaohui
    [J]. ACS OMEGA, 2019, 4 (07): : 11888 - 11892
  • [17] DIRECT ANTIGEN-DETECTION IN LANGMUIR-BLODGETT-FILMS OF IMMUNOGLOBULIN-G MODIFIED WITH COPROPORPHYRIN-I
    TURKO, IV
    LEPESHEVA, GI
    CHASHCHIN, VL
    [J]. ANALYTICA CHIMICA ACTA, 1992, 265 (01) : 21 - 26
  • [18] Separation-Free Electrogenerated Chemiluminescence Immunoassay Incorporating Target Assistant Proximity Hybridization and Dynamically Competitive Hybridization of a DNA Signal Probe
    Wang, Bing
    Shi, Suwen
    Yang, Xiaolin
    Wang, Yue
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (01) : 884 - 891
  • [19] Gold nanoparticles/L-cysteine/graphene composite based immobilization strategy for an electrochemical immunosensor
    Wang, Guangfeng
    Huang, Hao
    Zhang, Ge
    Zhang, Xiaojun
    Fang, Bin
    Wang, Lun
    [J]. ANALYTICAL METHODS, 2010, 2 (11) : 1692 - 1697
  • [20] A facile ratiometric electrochemical strategy for ultrasensitive monitoring HER2 using polydopamine-grafted-ferrocene/reduced graphene oxide, Au@Ag nanoshuttles and hollow Ni@PtNi yolk-shell nanocages
    Wang, Xiao-Yu
    Feng, Yi-Ge
    Wang, Ai-Jun
    Mei, Li-Ping
    Yuan, Pei-Xin
    Luo, Xiliang
    Feng, Jiu-Ju
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 331