摘要
The aim of this study is to develop an immunosensor that has the ability to detect antigen G with properties such as very low detection of limit, remarkable with no bifunctional crosslinking species and excellent activity at physiological pH values. Immunoglobulin G (IgG) is found in all body fluids. When a specific bond occurs be-tween the anti-immunoglobulin G and the immunoglobulin G (anti-IgG), the result is activation of the reaction against viral and bacterial diseases. For detection and determination of antibody-antigen (Rabbit IgG-AntiRabbit IgG) interactions, a novel electrochemical immunosensor based on antibody immunoglobulin G/3-(trimethoxysilyl)propylamine/graphene oxide/glassy carbon (Ab/TMSPA/GO/GCE) was fabricated by using of carboxylic groups (-COOH) on graphene oxide (GO) and by exploiting 3-(trimethoxysilyl)propylamine (TMSPA) to covalently conjugate antibody molecules. For characterization of the modification process of the surface of glassy carbon electrode(GCE), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used. The change of impedance response was used for the monitoring of the interactions of antibody with different concentrations of antigen. Based on the results obtained, with increasing concentrations of antigen, the electron transfer resistance increased. The limit of detection (DL) and linear range 400 ng mL(-1) and 2-1500 mu g mL(-1) were obtained.
引用
收藏
页数:8
相关论文
共 24 条
  • [1] Multiwall carbon nanotube-ionic liquid electrode modified with gold nanoparticles as a base for preparation of a novel impedimetric immunosensor for low level detection of human serum albumin in biological fluids
    Arkana, Elham
    Saber, Reza
    Karimi, Ziba
    Mostafaie, Ali
    Shamsipur, Mojtaba
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 92 : 74 - 81
  • [2] ALDEHYDE FUNCTIONALIZED ETHOXYSILANES AS NEW ENZYME IMMOBILIZATION REAGENTS
    BRUNING, C
    GROBE, J
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1995, (22) : 2323 - 2324
  • [3] Label-free electrochemical immunosensor for ultrasensitive determination of cardiac troponin I based on porous fluffy-like AuPtPd trimetallic alloyed nanodendrites
    Cen, Shi-Yun
    Ge, Xin-Yue
    Chen, Yao
    Wang, Ai-Jun
    Feng, Jiu-Ju
    [J]. MICROCHEMICAL JOURNAL, 2021, 169
  • [4] Eco-friendly one-pot aqueous synthesis of ultra-thin AuPdCu alloyed nanowire-like networks for highly sensitive immunoassay of creatine kinase-MB
    Cen, Shi-Yun
    Feng, Yi-Ge
    Zhu, Jian-Hong
    Wang, Xiao-Yu
    Wang, Ai-Jun
    Luo, Xiliang
    Feng, Jiu-Ju
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 333
  • [5] Fe3O4@PDA immune probe-based signal amplification in surface plasmon resonance (SPR) biosensing of human cardiac troponin I
    Chen, Fangfang
    Wu, Qiong
    Song, Daqian
    Wang, Xinghua
    Ma, Pinyi
    Sun, Ying
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 177 : 105 - 111
  • [6] Chitosan-graphene oxide based aptasensor for the impedimetric detection of lysozyme
    Erdem, Arzurn
    Eksin, Ece
    Muti, Mihrican
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 115 : 205 - 211
  • [7] Chiral electrochemical recognition by very thin molecularly imprinted sol-gel films
    Fireman-Shoresh, S
    Turyan, I
    Mandler, D
    Avnir, D
    Marx, S
    [J]. LANGMUIR, 2005, 21 (17) : 7842 - 7847
  • [8] Improving the diagnostic accuracy of N-terminal B-Type natriuretic peptide in human Systolic heart failure by plasma profiling using mass Spectrometry
    Jones, Donald J. L.
    Willingale, Richard
    Quinn, Paulene A.
    Lamb, John H.
    Farmer, Peter B.
    Davies, Joan E.
    Ng, Leong L.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2007, 6 (08) : 3329 - 3334
  • [9] Graphene-assisted dual amplification strategy for the fabrication of sensitive amperometric immunosensor
    Liu, Kunping
    Zhang, Jing-Jing
    Wang, Chunming
    Zhu, Jun-Jie
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3627 - 3632
  • [10] Core-shell magnetic nanoparticles applied for immobilization of antibody on carbon paste electrode and amperometric immunosensing
    Liu, ZM
    Yang, HF
    Li, YF
    Liu, YL
    Shen, GL
    Yu, RQ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 956 - 962