Determination of very low amounts of chromium(III) and (VI) using dispersive liquid-liquid microextraction by in situ formation of an ionic liquid followed by electrothermal atomic absorption spectrometry

被引:51
作者
Lopez-Garcia, Ignacio [1 ]
Vicente-Martinez, Yesica [1 ]
Hernandez-Cordoba, Manuel [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
SINGLE-DROP MICROEXTRACTION; PHASE MICROEXTRACTION; WATER SAMPLES; ANALYTICAL-CHEMISTRY; NATURAL-WATERS; SPECIATION; EXTRACTION; CR(VI); CR(III); PRECONCENTRATION;
D O I
10.1039/c2ja10378h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for the determination of very low levels of Cr(III) and Cr(VI) using ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS) is presented. The ionic liquid, 1-octyl-3-methylimidazolium bis(trifluoromethanesulfonyl) imide ([C(8)MIm][NTf2]), is formed in situ by mixing 1-octyl-3-methylimidazolium chloride ([C(8)MIm]Cl) and lithium bis(trifluoromethanesulfonyl) imide ([NTf2]Li) aqueous solutions, and is used to extract complexes originating from Cr(III) and Cr(VI) with ammonium pyrrolidinedithiocarbamate (APDC). No organic solvents are required, the dispersion being due to the very fine droplets of ([C(8)MIm][NTf2]) originated in the aqueous solution. After centrifugation, the concentration of chromium in the sedimented phase is determined by ETAAS. The total content of chromium is measured using 0.01 mol L-1 APDC at pH = 1. In the presence of 0.001 mol L-1 ethylenediaminetetraacetate, Cr(III) is not extracted, and the analytical signal corresponds to Cr(VI). The level of Cr(III) is obtained by difference. The enrichment factor of the procedure is 300 and a detection limit of 2 ng L-1 is achieved. The relative standard deviation for 10 replicates at the 0.05 mu g L-1 level is close to 8%. The recoveries of spiked samples are in the 95-104% range. The method is applied to the analysis of water samples as well as lixiviates obtained from toys made of plastic materials.
引用
收藏
页码:874 / 880
页数:7
相关论文
共 54 条
[1]   Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[2]  
[Anonymous], 1994, 71 EN 3
[3]   Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids [J].
Baghdadi, Majid ;
Shemirani, Farzaneh .
ANALYTICA CHIMICA ACTA, 2008, 613 (01) :56-63
[4]   Determination of chromium (III) in natural water samples utilizing capillary micro-extraction on nanometre zirconium phosphate coating coupled to electrothermal atomic absorbance spectrometry [J].
Bai, Xiaohong ;
Fan, Zhefeng .
JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (02) :326-329
[5]   Speciation of hexavalent chromium in waters by liquid-liquid extraction and GFAAS determination [J].
Beni, Aron ;
Karosi, Roland ;
Posta, Jozsef .
MICROCHEMICAL JOURNAL, 2007, 85 (01) :103-108
[6]   ANALYSIS OF DISSOLVED CR-3+ AND CR-6+ IN WATER BY APDC-MIBK EXTRACTION AND ATOMIC-ABSORPTION SPECTROMETRY [J].
BERGMANN, H ;
HARDT, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 297 (05) :381-383
[7]  
BRENNECKE JF, 2007, IONIC LIQUIDS, V4
[8]   Liquid-supported membranes in chromium(VI) optical sensing: transport modelling [J].
Castillo, E ;
Granados, M ;
Cortina, JL .
ANALYTICA CHIMICA ACTA, 2002, 464 (02) :197-208
[9]   Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD) [J].
Cathum, S ;
Brown, CE ;
Wong, W .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) :103-110
[10]   Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometry [J].
Chen, Hao ;
Du, Ping ;
Chen, Jie ;
Hu, Shenghua ;
Li, Shengqing ;
Liu, Hanlan .
TALANTA, 2010, 81 (1-2) :176-179