Safety and Efficacy of UltraShape Contour I Treatments to Improve the Appearance of Body Contours: Multiple Treatments in Shorter Intervals

被引:53
作者
Ascher, Benjamin [1 ]
机构
[1] Paris Acad, Clin Iena, F-75116 Paris, France
关键词
UltraShape; body contouring; fat reduction; FLUID RESUSCITATION; ASSISTED LIPOPLASTY; FOCUSED ULTRASOUND; LIPOSUCTION; LIDOCAINE;
D O I
10.1177/1090820X09360692
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The UltraShape Contour I System (CE 0344; UltraShape Ltd., Yoqneam, Israel) is a noninvasive fat reduction and body contouring system currently approved for use outside the United States that utilizes focused ultrasound to selectively disrupt adipocytes. Objective: To evaluate the clinical safety and efficacy of the Contour I system when the intervals between treatments are shortened. Methods: Twenty-five healthy Caucasian women were selected from the patient population at two clinics in Paris, France, and received three 30- to 90-minute Contour I treatments in the abdominal region at two-week intervals. Safety parameters evaluated included adverse events, local skin reaction, and pain. Efficacy parameters evaluated included treatment area circumference, body weight, and comparison of before and after photos. Untreated thigh areas served as an internal control. Subjects were followed for 84 days after the last treatment (day 112). Results: No adverse events occurred. The majority of subjects (n = 23; similar to 90%) reported no pain. Mean midline circumference (2 cm below midline) was reduced by 2.47 cm (P < .001) on day 14 after the first Contour I treatment, 3.51 cm (P < .001) on day 56, and 3.58 cm (P < .001) on day 112. Peak midline circumference reduction was 3.12 cm on day 112. Most patients (n = 14; 63%) reported a positive change in body contour. Mean thigh circumference (the control area) was unchanged; the relative change between treated and untreated areas of the abdomen was significantly different at all time points. Circumference and weight reduction were significantly correlated (r = 0.42-0.71) at all time points; mean weight decrease was not statistically significant. Circumference reduction on day 112 positively correlated with patients' subjective satisfaction scores. Conclusions: Our data showed that successive Contour I treatments at two-week intervals were safe and tolerable and also significantly reduced treatment area circumference.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 44 条
  • [1] Analysis of the effects of deep mechanical massage in the porcine model
    Adcock, D
    Paulsen, S
    Jabour, K
    Davis, S
    Nanney, LB
    Shack, RB
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (01) : 233 - 240
  • [2] *AM OB ASS, AM OBESITY ASS FACT, V2006
  • [3] *ASAPS, 2007, COSM SURG NAT DAT BA
  • [4] *ASAPS, 2005, COSM SURG NAT DAT BA
  • [5] Avram Mathew M, 2004, J Cosmet Laser Ther, V6, P181
  • [6] Characterization of Nonthermal Focused Ultrasound for Noninvasive Selective Fat Cell Disruption (Lysis): Technical and Preclinical Assessment
    Brown, Spencer A.
    Greenbaum, Lior
    Shtukmaster, Stella
    Zadok, Yehuda
    Ben-Ezra, Shmuel
    Kushkuley, Leonid
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (01) : 92 - 101
  • [7] Clinical Efficacy of Noninvasive Cryolipolysis and Its Effects on Peripheral Nerves
    Coleman, Sydney R.
    Sachdeva, Kulveen
    Egbert, Barbara M.
    Preciado, Jessica
    Allison, John
    [J]. AESTHETIC PLASTIC SURGERY, 2009, 33 (04) : 482 - 488
  • [8] Extracorporeal shock waves act by shock wave-gas bubble interaction
    Delius, M
    Ueberle, F
    Eisenmenger, W
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (07) : 1055 - 1059
  • [9] ULTRASONIC SURGICAL DISSECTION IN THE DOG SPLEEN
    DERDERIAN, GP
    WALSHAW, R
    MCGEHEE, J
    [J]. AMERICAN JOURNAL OF SURGERY, 1982, 143 (02) : 269 - 273
  • [10] Epstein F, 1983, Clin Neurosurg, V31, P497