Effect of clothing on sphygmomanometric and oscillometric blood pressure measurement in hypertensive subjects

被引:8
作者
Eder, M. J. C. [1 ]
Holzgreve, H. [2 ]
Liebl, M. E. [3 ]
Bogner, J. R. [1 ]
机构
[1] Univ Munich, Klinikum Innenstadt, Med Poliklin, D-80336 Munich, Germany
[2] Kardiol Praxis, Munich, Germany
[3] Abt Orthopad, Med Klin, Berlin, Germany
关键词
hypertension; blood pressure measurement; oscillometry; sphygmomanometry; clothes;
D O I
10.1055/s-2008-1077254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: The few studies published on this subject have shown that blood pressure measurements give similar results whether the patients' arm is covered by clothing or not. But it has not been clarified whether this is also true in the case of hypertensive persons, Yet, in practice the correct measurement is of critical importance in the diagnosis of hypertension. Methods: 203 hypertensive patients were examined with the auscultatory sphygmomanometry and the automatic oscillometry by measuring the pressure three times with each method. These tests were carried out in a randomized sequence on a covered arm (the patient's own clothing of maximally 2 mm thickness), the bare arm and the arm covered with a standardized cotton sleeve (2 mm). The auscultatory sphygmomanometry was done blinded (non-sleeved, sleeved, standardized). Results: Calculation of confidence intervals for the mean differences of the three settings (bare, clothing and standard sleeve) and equivalence testing demonstrated that a garment or cloth on the arm under the manometer cuffs did not significantly effect the blood pressure within the predefined interval of equivalence of 4 mm Hg. Thus, measuring blood pressure with the cuff over the person's sleeve does not significantly effect the result. Conclusion: This study shows that measuring blood pressure in hypertensive persons with or without a cloth sleeve (maximally 2 mm thick) does not result in any statistically significant difference. This simplifies the blood pressure measurement that have to be taken frequently on hypertensive persons.
引用
收藏
页码:1288 / 1292
页数:5
相关论文
共 21 条
  • [1] Association for the Advancement of Medical Instrumentation, 1993, ANSI AAMI SP, P40
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] *EUR SOC HYP WORK, 2003, J HYPERTENS, V322, P821
  • [4] FROHLICH ED, 1995, CAN J CARDIOL, V11, pH35
  • [5] THE EFFECT OF SLEEVED ARMS ON OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT
    HOLLEMAN, DR
    WESTMAN, EC
    MCCRORY, DC
    SIMEL, DL
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 1993, 8 (06) : 325 - 326
  • [6] POSTPRANDIAL HYPOTENSION - EPIDEMIOLOGY, PATHOPHYSIOLOGY, AND CLINICAL MANAGEMENT
    JANSEN, RWMM
    LIPSITZ, LA
    [J]. ANNALS OF INTERNAL MEDICINE, 1995, 122 (04) : 286 - 295
  • [7] Comparison of blood pressure measurements on the bare arm, below a rolled-up sleeve, or over a sleeve
    Kahan, E
    Yaphe, J
    Knaani-Levinz, H
    Weingarten, MA
    [J]. FAMILY PRACTICE, 2003, 20 (06) : 730 - 732
  • [8] The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement
    Liebl, ME
    Holzgreve, H
    Schulz, M
    Crispin, A
    Bogner, JR
    [J]. BLOOD PRESSURE, 2004, 13 (05): : 279 - 282
  • [9] Das Theorie-Praxis-Problem bei der BlutdruckbeurteilungThe theory–practice problem of blood pressure assessment
    Dieter Magometschnigg
    [J]. Wiener Medizinische Wochenschrift, 2004, 154 (1-2) : 20 - 23
  • [10] Systematic review of the effect of daily alcohol intake on blood pressure
    McFadden, CB
    Brensinger, CM
    Berlin, JA
    Townsend, RR
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (02) : 276 - 286