Are brain currents detectable by means of low-field NMR? A phantom study

被引:18
作者
Hoefner, Nora [1 ]
Albrecht, Hans-Helge [1 ]
Cassara, Antonino Mario [2 ,3 ,4 ]
Curio, Gabriel [5 ]
Hartwig, Stefan [1 ]
Haueisen, Jens [6 ,7 ]
Hilschenz, Ingo [1 ]
Koerber, Rainer [1 ]
Martens, Sven [6 ]
Scheer, Hans-Juergen [1 ]
Voigt, Jens [1 ]
Trahms, Lutz [1 ]
Burghoff, Martin [1 ]
机构
[1] PTB, D-10587 Berlin, Germany
[2] Museo Stor Fis, Rome, Italy
[3] Ctr Studi & Ric E Fermi, Rome, Italy
[4] Univ Roma La Sapienza, Grp G1, Dip Fis, I-00185 Rome, Italy
[5] Charite, Dept Neurol, D-12200 Berlin, Germany
[6] Ilmenau Univ Technol, Inst Biomed Engn & Informat, Ilmenau, Germany
[7] Univ Hosp Jena, Biomagnet Ctr, Dept Neurol, Jena, Germany
关键词
Neuronal currents; Saline dipole phantom; Low-Field NMR; MEG; NEURONAL CURRENTS; MAGNETIC-FIELDS; LOCALIZATION; MAGNETOENCEPHALOGRAPHY; ACTIVATION; MEG;
D O I
10.1016/j.mri.2011.07.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A number of different methods have been developed in order to detect the spreading of neuronal currents by means of noninvasive imaging techniques. However, all of these are subjected to limitations in the temporal or spatial resolution. A new approach of neuronal current detection is based on the use of low-field nuclear magnetic resonance (LF-NMR) that records brain activity directly. In the following, we describe a phantom study in order to assess the feasibility of neuronal current detection using LF-NMR. In addition to that, necessary preliminary subject studies examining somatosensory evoked neuronal currents are presented. During the phantom study, the influences of two different neuronal time signals on H-1-NMR signals were observed. The measurements were carried out by using a head phantom with an integrated current dipole to simulate neuronal activity. Two LF-NMR methods based on a DC and an AC (resonant) mechanism were utilized to study the feasibility of detecting both types of magnetic brain signals. Measurements were made inside an extremely magnetically shielded room by using a superconducting quantum interference device magnetometer system. The measurement principles were validated applying currents of higher intensity than those typical of the neuronal currents. Through stepwise reduction of the amplitude of the current dipole strength, the resolution limits of the two measuring procedures were found. The results indicate that it is necessary to improve the signal-to-noise ratio of the measurement system by at least a factor of 38 in order to detect typical human neuronal activity directly by means of LF-NMR. In addition to that, ways of achieving this factor are discussed. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1365 / 1373
页数:9
相关论文
共 27 条
[1]   FUNDAMENTALS OF ELECTROENCEFALOGRAPHY, MAGNETOENCEFALOGRAPHY, AND FUNCTIONAL MAGNETIC RESONANCE IMAGING [J].
Babiloni, Claudio ;
Pizzella, Vittorio ;
Del Gratta, Cosimo ;
Ferretti, Antonio ;
Romani, Gian Luca .
BRAIN MACHINE INTERFACES FOR SPACE APPLICATIONS: ENHANCING ASTRONAUT CAPABILITIES, 2009, 86 :67-80
[2]   Direct detection of neuronal activity with MRI: Fantasy, possibility, or reality? [J].
Bandettini, PA ;
Petridou, N ;
Bodurka, J .
APPLIED MAGNETIC RESONANCE, 2005, 29 (01) :65-88
[3]   Modelling the magnetic signature of neuronal tissue [J].
Blagoev, K. B. ;
Mihaila, B. ;
Travis, B. J. ;
Alexandrov, L. B. ;
Bishop, A. R. ;
Ranken, D. ;
Posse, S. ;
Gasparovic, C. ;
Mayer, A. ;
Aine, C. J. ;
Ulbert, I. ;
Morita, M. ;
Muller, W. ;
Connor, J. ;
Halgren, E. .
NEUROIMAGE, 2007, 37 (01) :137-148
[4]   Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic fields changes [J].
Bodurka, J ;
Bandettini, PA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1052-1058
[5]   dc Magnetoencephalography: Direct measurement in a magnetically extremely-well shielded room [J].
Burghoff, M ;
Sander, TH ;
Schnabel, A ;
Drung, D ;
Trahms, L ;
Curio, G ;
Mackert, BM .
APPLIED PHYSICS LETTERS, 2004, 85 (25) :6278-6280
[6]  
Burghoff M, 2005, APPL PHYS LETT, V054103, P87
[7]  
Burghoff M, 2010, APPL PHYS LETT, V233701, P96
[8]  
Burghoff M, 2009, METROL MEAS SYST, V16, P371
[9]   Realistic simulations of neuronal activity: A contribution to the debate on direct detection of neuronal currents by MRI [J].
Cassara, A. M. ;
Hagberg, G. E. ;
Bianciardi, M. ;
Migliore, M. ;
Maraviglia, B. .
NEUROIMAGE, 2008, 39 (01) :87-106
[10]   Neuronal current detection with low-field magnetic resonance: simulations and methods [J].
Cassara, Antonino Mario ;
Maraviglia, Bruno ;
Hartwig, Stefan ;
Trahms, Lutz ;
Burghoff, Martin .
MAGNETIC RESONANCE IMAGING, 2009, 27 (08) :1131-1139