Matrix-assisted laser desorption/ionization of amphiphilic fullerene derivatives

被引:54
|
作者
Brown, T
Clipston, NL
Simjee, N
Luftmann, H
Hungerbühler, H
Drewello, T [1 ]
机构
[1] Univ Warwick, Dept Chem, Coventry CV4 7AL, W Midlands, England
[2] Univ Munster, Inst Organ Chem, D-48149 Munster, Germany
[3] Tech Fachhsch Berlin, Fachbereich Pharma & Chemietech, D-13353 Berlin, Germany
基金
英国工程与自然科学研究理事会;
关键词
matrix-assisted laser desorption/ionization; matrix; fullerene derivatives; mass spectrometry;
D O I
10.1016/S1387-3806(01)00429-8
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Matrix-assisted laser desorption/ionization (MALDI) coupled with reflectron time-of-flight mass spectrometry has been applied to the analysis of fullerene derivatives. As a common structural feature, the derivatised fullerenes comprised a long chained, organic ligand connected via a methylene bridge to the [60]fullerene. Using a structurally similar model analyte, this investigation includes the screening of fourteen different compounds regarding their suitability as MALDI matrices. The appearance of positive- and negative-ion mass spectra has been detailed, and the analysis has been supported by post source decay experiments. It was found that the performance of 9-nitroanthracene, which is currently one of the most universally used matrices for the analysis of fullerene derivatives, is exceeded by some of these materials. In the negative-ion mode, excellent performance has been achieved using the two structurally related beta -carboline alkaloids, harmane and nor-harmane, as matrices. However, the best results for the analytes investigated here have been obtained employing 2-[(2 E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), This matrix provides analyte signals in both ion modes at comparatively lower threshold laser fluences, leading to mass spectra, which display a very low degree of unwanted dissociations of the analyte. The formation of molecular analyte ions prevails, rather than ionization occurring via protonation or deprotonation. DCTB also efficiently promotes metal ion attachment to suitably ligated fullerene derivatives. (C) 2001 Elsevier Science B.V.
引用
收藏
页码:249 / 263
页数:15
相关论文
共 50 条
  • [1] Drawing a different picture with pencil lead as matrix-assisted laser desorption/ionization matrix for fullerene derivatives
    Nye, Leanne C.
    Hungerbuehler, Hartmut
    Drewello, Thomas
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2018, 24 (01) : 81 - 88
  • [2] Matrix-assisted laser desorption/ionization
    Kazazic, S.
    Pecur, S.
    Srzic, D.
    Kemija u industriji/Journal of Chemists and Chemical Engineers, 1999, 48 (05): : 181 - 187
  • [4] Ionization Mechanism of Matrix-Assisted Laser Desorption/Ionization
    Lu, I-Chung
    Lee, Chuping
    Lee, Yuan-Tseh
    Ni, Chi-Kung
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 8, 2015, 8 : 21 - 39
  • [6] Lasers for matrix-assisted laser desorption ionization
    Murray, Kermit K.
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (06):
  • [7] Matrix-assisted laser desorption/ionization of ginsenosides
    Zhou, Y
    Song, FR
    Liu, SY
    Li, XG
    ACTA CHIMICA SINICA, 1998, 56 (03) : 298 - 301
  • [8] Initial Ionization Reaction in Matrix-Assisted Laser Desorption/Ionization
    Liu, Bo-Hong
    Charkin, Oleg P.
    Klemenko, Nina
    Chen, Chiu Wen
    Wang, Yi-Sheng
    JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (33): : 10853 - 10859
  • [9] Mass Spectrometry - Matrix-Assisted Laser Desorption/Ionization
    Harvey, D.J.
    Encycl. of Anal. Sci.: Second Ed., (386-397):
  • [10] Ionization modelling of matrix molecules in ultraviolet matrix-assisted laser desorption/ionization
    Allwood, DA
    Dyer, PE
    Dreyfus, RW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (05) : 499 - 503