AN EXPERIMENTAL INVESTIGATION OF FULL-COVERAGE FILM COOLING EFFECTIVENESS AND HEAT TRANSFER COEFFICIENT OF A TURBINE GUIDE VANE IN A LINEAR TRANSONIC CASCADE

被引:0
作者
Fu, Zhong-yi [1 ]
Zhu, Hui-ren [1 ]
Liu, Cun-liang [1 ]
Liu, Cong [1 ]
Li, Zheng [1 ]
机构
[1] Northwestern Poly Tech Univ, Sch Engine & Energy, Xian 710072, Peoples R China
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 5C | 2016年
关键词
HOLES; ANGLES; WALLS;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper experimentally investigates the film cooling performance of an enlarged turbine guide vane with full-coverage cylindrical hole film cooling in short duration transonic wind tunnel which can model realistic engine aerodynamic conditions and adjust inlet Reynolds number and isentropic exit Mach number independently. The effects of mass flow rate ratio (MFR=4.83%similar to 8.83%), inlet Reynolds number (Re-in= 1.7x10(5)similar to 5.7x10(5)), and is entropic exit Mach number (Ma(is)=0.81 similar to 1.01) are investigated. There are five rows of cylindrical film cooling holes on the pressure side and four such rows on the suction side respectively. Another four rows of cylindrical holes are provided on the leading edge to obtain a showerhead film cooling. The surface heat transfer coefficient and adiabatic film cooling effectiveness are derived from the surface temperatures measured by the thermocouples mounted.in the middle span of the vane surface based on transient heat transfer measurement method. Mass flow rate ratio is shown to have a significant effect on film cooling effectiveness. The increase of mass flow rate ratio increases film cooling effectiveness on pressure side, while increasing this factor has opposite effect on film cooling effectiveness on the suction side. At the same mass flow rate ratio, increasing the Reynolds number can enhance the film cooling performance, the expectation is that at low mass flow rate ratio condition increasing the Reynolds number decreases film cooling effectiveness on the pressure side. The heat transfer coefficient increases with the mass flow rate ratio increasing on both pressure and suction side. At middle and high inlet Reynolds number condition, in the region of 0.4<s<0.6 on suction side, the coolant weakens heat transfer adversely.
引用
收藏
页数:12
相关论文
共 21 条
  • [1] Barigozzi, 2011, J TURBOMACH, V134, P399
  • [2] BROWN KH, 1995, AIAA19950796
  • [3] Ekkad S. V., 1997, 95GT010 ASME
  • [4] Row-of-holes film cooling of curved walls at low injection angles
    Goldstein, RJ
    Stone, LD
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 574 - 579
  • [5] Film-cooling holes with expanded exits: near-hole heat transfer coefficients
    Gritsch, M
    Schulz, A
    Wittig, S
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2000, 21 (02) : 146 - 155
  • [6] Full-coverage film cooling with short normal injection holes
    Harrington, MK
    McWaters, MA
    Bogard, DG
    Lemmon, CA
    Thole, KA
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 798 - 805
  • [7] Jia L. I., 2011, J ENG THERMOPHYSICS, V32, P1295
  • [8] Joshua B. A., 2013, GT201395243 ASME
  • [9] Kelly G. B., 2003, GT200338716 ASME
  • [10] Lin Y, 2003, P ASME TURB EXP 2003, P651