Fabrication of Wearable PDMS Device for Rapid Detection of Nucleic Acids via Recombinase Polymerase Amplification Operated by Human Body Heat

被引:25
作者
Trinh, Kieu The Loan [1 ]
Lee, Nae Yoon [2 ]
机构
[1] Gachon Univ, Dept Ind Environm Engn, 1342 Seongnam Daero, Seongnam Si 13120, Gyeonggi Do, South Korea
[2] Gachon Univ, Dept BioNano Technol, 1342 Seongnam Daero, Seongnam Si 13120, Gyeonggi Do, South Korea
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 02期
基金
新加坡国家研究基金会;
关键词
wearable RPA microdevice; poly(dimethylsiloxane) (PDMS); human body heat; recombinase polymerase amplification (RPA); DNA; SOFT;
D O I
10.3390/bios12020072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pathogen detection by nucleic acid amplification proved its significance during the current coronavirus disease 2019 (COVID-19) pandemic. The emergence of recombinase polymerase amplification (RPA) has enabled nucleic acid amplification in limited-resource conditions owing to the low operating temperatures around the human body. In this study, we fabricated a wearable RPA microdevice using poly(dimethylsiloxane) (PDMS), which can form soft-but tight-contact with human skin without external support during the body-heat-based reaction process. In particular, the curing agent ratio of PDMS was tuned to improve the flexibility and adhesion of the device for better contact with human skin, as well as to temporally bond the microdevice without requiring further surface modification steps. For PDMS characterization, water contact angle measurements and tests for flexibility, stretchability, bond strength, comfortability, and bendability were conducted to confirm the surface properties of the different mixing ratios of PDMS. By using human body heat, the wearable RPA microdevices were successfully applied to amplify 210 bp from Escherichia coli O157:H7 (E. coli O157:H7) and 203 bp from the DNA plasmid SARS-CoV-2 within 23 min. The limit of detection (LOD) was approximately 500 pg/reaction for genomic DNA template (E. coli O157:H7), and 600 fg/reaction for plasmid DNA template (SARS-CoV-2), based on gel electrophoresis. The wearable RPA microdevice could have a high impact on DNA amplification in instrument-free and resource-limited settings.
引用
收藏
页数:13
相关论文
共 33 条
[1]   Polymerase chain reaction in microfluidic devices [J].
Ahrberg, Christian D. ;
Manz, Andreas ;
Chung, Bong Geun .
LAB ON A CHIP, 2016, 16 (20) :3866-3884
[2]   Evaluation of polydimethylsiloxane scaffolds with physiologically-relevant elastic moduli: interplay of substrate mechanics and surface chemistry effects on vascular smooth muscle cell response [J].
Brown, XQ ;
Ookawa, K ;
Wong, JY .
BIOMATERIALS, 2005, 26 (16) :3123-3129
[3]   Efficient Bond of PDMS and Printed Circuit Board with An Application on Continuous-flow Polymerase Chain Reaction [J].
Chang, Yongjia ;
You, Hui .
BIOCHIP JOURNAL, 2020, 14 (04) :349-357
[4]   Recombinase Polymerase Amplification for Diagnostic Applications [J].
Daher, Rana K. ;
Stewart, Gale ;
Boissinot, Maurice ;
Bergeron, Michel G. .
CLINICAL CHEMISTRY, 2016, 62 (07) :947-958
[5]   Recombinase Polymerase Amplification (RPA) for the Rapid Isothermal Detection of Spongospora subterranea f. sp. subterranea and Potato Mop-Top Virus [J].
DeShields, Joseph B. ;
Moroz, Natalia ;
Braley, Lauren E. ;
Mora-Romero, Guadalupe Arlene ;
Tanaka, Kiwamu .
AMERICAN JOURNAL OF POTATO RESEARCH, 2019, 96 (06) :617-624
[6]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[7]   Microfluidic-Based Nucleic Acid Amplification Systems in Microbiology [J].
Gorgannezhad, Lena ;
Stratton, Helen ;
Nam-Trung Nguyen .
MICROMACHINES, 2019, 10 (06)
[8]   PDMS-Based Elastomer Tuned Soft, Stretchable, and Sticky for Epidermal Electronics [J].
Jeong, Seung Hee ;
Zhang, Shuo ;
Hjort, Klas ;
Hilborn, Jons ;
Wu, Zhigang .
ADVANCED MATERIALS, 2016, 28 (28) :5830-+
[9]   Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays [J].
Khademhosseini, A ;
Yeh, J ;
Eng, G ;
Karp, J ;
Kaji, H ;
Borenstein, J ;
Farokhzad, OC ;
Langer, R .
LAB ON A CHIP, 2005, 5 (12) :1380-1386
[10]   Fabrication of a foldable all-in-one point-of-care molecular diagnostic microdevice for the facile identification of multiple pathogens [J].
Kieu The Loan Trinh ;
Stabler, Richard A. ;
Lee, Nae Yoon .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 314 (314)