Site-Dependent Osseointegration of Biodegradable High-Purity Magnesium for Orthopedic Implants in Femoral Shaft and Femoral Condyle of New Zealand Rabbits

被引:15
作者
Cheng, Pengfei [1 ]
Zhao, Changli [2 ]
Han, Pei [1 ]
Ni, Jiahua [2 ]
Zhang, Shaoxiang [3 ]
Zhang, Xiaonong [2 ,3 ]
Chai, Yimin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Orthopaed, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mat Sci & Engn, State Key Lab Met Matrix Composites, Shanghai 200240, Peoples R China
[3] Suzhou Origin Med Technol Co Ltd, Suzhou 215513, Peoples R China
基金
中国国家自然科学基金;
关键词
Osseointegration; High-purity magnesium; Site-dependent; Femoral shaft and condyle; Bioadaption; IN-VIVO DEGRADATION; BONE; ALLOYS; VITRO; BIOCOMPATIBILITY; CORROSION; PHOSPHATE; BEHAVIOR; SCREWS; ZEK100;
D O I
10.1016/j.jmst.2016.03.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnesium (Mg) has been widely accepted as osteoconductive biomaterial, but osseointegration of Mg device at different implantation sites is still unclear. In the present study, high-purity magnesium (HP Mg) pins were implanted into femoral shaft and condyle of New Zealand rabbits concurrently. 2, 8, 12 and 16 weeks after surgery, rabbit femurs were harvested for micro-computed tomography (micro-CT) scanning and subsequent histological examinations. HP Mg pins were retrieved for scanning electron microscope and energy dispersive spectrum (SEM/EDS) analyses. HP Mg pins at both implantation sites performed stable corrosion with mineral deposition and bone incorporation on surface. However, difference in distribution of contact osteogenesis centers and biological properties of peri-implant bone tissues was detected between femoral shaft and femoral condyle. In femoral condyle, contact osteogenesis centers originated from both periosteum and cancellous bones and the whole HP Mg pin was encapsuled in trabecular bone at 16 weeks. Meanwhile, bone volume to total bone volume (BV/TV) and bone mineral density (BMD) of peri-implant bone tissues were above those of normal bone tissues. In femoral shaft, contact osteogenesis centers were only from periosteum and direct bone contact was confined in cortical bone, while BV/TV and BMD kept lower than normal. Furthermore, new formation of peri-implant bone tissues was more active in femoral condyle than in femoral shaft at 16 weeks. Therefore, although HP Mg performed good biocompatibility and corrosion behavior in vivo, its bioadaption of osseointegration at different implantations sites should be taken into consideration. Bone metaphysic was suitable for Mg devices where peri-implant bone tissues regenerated rapidly and the biological properties were close to normal bone tissues. Copyright (C) 2016, The editorial office of Journal of Materials Science & Technology. Published by Elsevier Limited.
引用
收藏
页码:883 / 888
页数:6
相关论文
共 29 条
[1]   Osteoinduction, osteoconduction and osseointegration [J].
Albrektsson, T ;
Johansson, C .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S96-S101
[2]   Angiogenesis and bone repair [J].
Carano, RAD ;
Filvaroff, EH .
DRUG DISCOVERY TODAY, 2003, 8 (21) :980-989
[3]   In vivo study of magnesium plate and screw degradation and bone fracture healing [J].
Chaya, Amy ;
Yoshizawa, Sayuri ;
Verdelis, Kostas ;
Myers, Nicole ;
Costello, Bernard J. ;
Chou, Da-Tren ;
Pal, Siladitya ;
Maiti, Spandan ;
Kumta, Prashant N. ;
Sfeir, Charles .
ACTA BIOMATERIALIA, 2015, 18 :262-269
[4]   Fracture Healing Using Degradable Magnesium Fixation Plates and Screws [J].
Chaya, Amy ;
Yoshizawa, Sayuri ;
Verdelis, Kostas ;
Noorani, Sabrina ;
Costello, Bernard J. ;
Sfeir, Charles .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (02) :295-305
[5]  
Davies John E, 2003, J Dent Educ, V67, P932
[6]   Long-term in vivo degradation behaviour and biocompatibility of the magnesium alloy ZEK100 for use as a biodegradable bone implant [J].
Dziuba, Dina ;
Meyer-Lindenberg, Andrea ;
Seitz, Jan Marten ;
Waizy, Hazibullah ;
Angrisani, Nina ;
Reifenrath, Janin .
ACTA BIOMATERIALIA, 2013, 9 (10) :8548-8560
[7]   Biomechanical testing and degradation analysis of MgCa0.8 alloy screws: A comparative in vivo study in rabbits [J].
Erdmann, Nina ;
Angrisani, Nina ;
Reifenrath, Janin ;
Lucas, Arne ;
Thorey, Fritz ;
Bormann, Dirk ;
Meyer-Lindenberg, Andrea .
ACTA BIOMATERIALIA, 2011, 7 (03) :1421-1428
[8]   In vivo degradation performance of micro-arc-oxidized magnesium implants: A micro-CT study in rats [J].
Fischerauer, S. F. ;
Kraus, T. ;
Wu, X. ;
Tangl, S. ;
Sorantin, E. ;
Haenzi, A. C. ;
Loeffler, J. F. ;
Uggowitzer, P. J. ;
Weinberg, A. M. .
ACTA BIOMATERIALIA, 2013, 9 (02) :5411-5420
[9]   In vitro and in vivo studies on the degradation of high-purity Mg (99.99wt.%) screw with femoral intracondylar fractured rabbit model [J].
Han, Pei ;
Cheng, Pengfei ;
Zhang, Shaoxiang ;
Zhao, Changli ;
Ni, Jiahua ;
Zhang, Yuanzhuang ;
Zhong, Wanrun ;
Hou, Peng ;
Zhang, Xiaonong ;
Zheng, Yufeng ;
Chai, Yimin .
BIOMATERIALS, 2015, 64 :57-69
[10]   Shape and Site Dependent in Vivo Degradation of Mg-Zn Pins in Rabbit Femoral Condyle [J].
Han, Pei ;
Tan, Moyan ;
Zhang, Shaoxiang ;
Ji, Weiping ;
Li, Jianan ;
Zhang, Xiaonong ;
Zhao, Changli ;
Zheng, Yufeng ;
Chai, Yimin .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (02) :2959-2970