Comparison of Vibrational Spectroscopic Techniques for Quantification of Water in Natural Deep Eutectic Solvents

被引:6
|
作者
Elderderi, Suha [1 ,2 ]
Sacre, Pierre-Yves [3 ]
Wils, Laura [4 ]
Chourpa, Igor [1 ]
Elbashir, Abdalla A. [5 ,6 ]
Hubert, Philippe [3 ]
Byrne, Hugh J. [7 ]
Boudesocque-Delaye, Leslie [4 ]
Ziemons, Eric [3 ]
Bonnier, Franck [1 ]
机构
[1] Univ Tours, Fac Pharm, EA Nanomedicaments & Nanosondes 6295, 31 Ave Monge, F-37200 Tours, France
[2] Univ Gezira, Fac Pharm, Dept Pharmaceut Chem, POB 20, Wad Madani 21111, Sudan
[3] Univ Liege, Lab Pharmaceut Analyt Chem, Vibra Sante HUB, CIRM,ULiege, Ave Hippocrate 15, B-4000 Liege, Belgium
[4] Univ Tours, EA Synth & Isolement Mol BioAct SIMBA 7502, 31 Ave Monge, F-37200 Tours, France
[5] King Faisal Univ, Coll Sci, Dept Chem, POB 400, Al Hasa 31982, Saudi Arabia
[6] Univ Khartoum, Fac Sci, Dept Chem, POB 321, Khartoum 11115, Sudan
[7] Technol Univ Dublin, FOCAS Res Inst, City Campus,Dublin 8, Dublin D08 CKP1, Ireland
来源
MOLECULES | 2022年 / 27卷 / 15期
关键词
label-free water quantification; natural deep eutectic solvent; partial least squares regression; attenuated total reflection infrared; Raman spectroscopy; near infrared spectroscopy; NEAR-INFRARED SPECTROSCOPY; ATTENUATED TOTAL-REFLECTION; RAMAN-SPECTROSCOPY; QUANTITATIVE-ANALYSIS; MOISTURE-CONTENT; FT-IR; SPECTRA; SKIN; IDENTIFICATION; GLASSES;
D O I
10.3390/molecules27154819
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Vibrational spectroscopic techniques, i.e., attenuated total reflectance infrared (ATR-IR), near infrared spectroscopy (NIRS) and Raman spectroscopy (RS), coupled with Partial Least Squares Regression (PLSR), were evaluated as cost-effective label-free and reagent-free tools to monitor water content in Levulinic Acid/L-Proline (LALP) (2:1, mol/mol) Natural Deep Eutectic Solvent (NADES). ATR-IR delivered the best outcome of Root Mean Squared Error (RMSE) of Cross-Validation (CV) = 0.27% added water concentration, RMSE of Prediction (P) = 0.27% added water concentration and mean % relative error = 2.59%. Two NIRS instruments (benchtop and handheld) were also compared during the study, respectively yielding RMSECV = 0.35% added water concentration, RMSEP = 0.56% added water concentration and mean % relative error = 5.13% added water concentration, and RMECV = 0.36% added water concentration, RMSEP = 0.68% added water concentration and mean % relative error = 6.23%. RS analysis performed in quartz cuvettes enabled accurate water quantification with RMECV = 0.43% added water concentration, RMSEP = 0.67% added water concentration and mean % relative error = 6.75%. While the vibrational spectroscopic techniques studied have shown high performance in relation to reliable determination of water concentration, their accuracy is most likely related to their sensitivity to detect the LALP compounds in the NADES. For instance, whereas ATR-IR spectra display strong features from water, Levulinic Acid and L-Proline that contribute to the PLSR predictive models constructed, NIRS and RS spectra are respectively dominated by either water or LALP compounds, representing partial molecular information and moderate accuracy compared to ATR-IR. However, while ATR-IR instruments are common in chemistry and physics laboratories, making the technique readily transferable to water quantification in NADES, Raman spectroscopy offers promising potential for future development for in situ, sample withdrawal-free analysis for high throughput and online monitoring.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Comparison of Raman and attenuated total reflectance (ATR) infrared spectroscopy for water quantification in natural deep eutectic solvent
    Elderderi, Suha
    Wils, Laura
    Leman-Loubiere, Charlotte
    Henry, Sandra
    Byrne, Hugh J.
    Chourpa, Igor
    Munnier, Emilie
    Elbashir, Abdalla A.
    Boudesocque-Delaye, Leslie
    Bonnier, Franck
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (19) : 4785 - 4799
  • [2] In Situ Water Quantification in Natural Deep Eutectic Solvents Using Portable Raman Spectroscopy
    Elderderi, Suha
    Wils, Laura
    Leman-Loubiere, Charlotte
    Byrne, Hugh J.
    Chourpa, Igor
    Enguehard-Gueiffier, Cecile
    Munnier, Emilie
    Elbashir, Abdalla A.
    Boudesocque-Delaye, Leslie
    Bonnier, Franck
    MOLECULES, 2021, 26 (18):
  • [3] Comparison of Raman and attenuated total reflectance (ATR) infrared spectroscopy for water quantification in natural deep eutectic solvent
    Suha Elderderi
    Laura Wils
    Charlotte Leman-Loubière
    Sandra Henry
    Hugh J. Byrne
    Igor Chourpa
    Emilie Munnier
    Abdalla A. Elbashir
    Leslie Boudesocque-Delaye
    Franck Bonnier
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4785 - 4799
  • [4] Investigation of tetrabutylammonium bromide-glycerol-based deep eutectic solvents and their mixtures with water by spectroscopic techniques
    Chroma, Renata
    Vilkova, Maria
    Shepa, Ivan
    Makos-Chelstowska, Patrycja
    Andruch, Vasil
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 330
  • [5] Tailoring properties of natural deep eutectic solvents with water to facilitate their applications
    Dai, Yuntao
    Witkamp, Geert-Jan
    Verpoorte, Robert
    Choi, Young Hae
    FOOD CHEMISTRY, 2015, 187 : 14 - 19
  • [6] Application of Vibrational Spectroscopic Techniques in the Study of the Natural Polysaccharides and Their Cross-Linking Process
    Gieroba, Barbara
    Kalisz, Grzegorz
    Krysa, Mikolaj
    Khalavka, Maryna
    Przekora, Agata
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (03)
  • [7] Improving Whole-Cell Biocatalysis by Addition of Deep Eutectic Solvents and Natural Deep Eutectic Solvents
    Yang, Tao-Xiang
    Zhao, Li-Qing
    Wang, Juan
    Song, Guo-Li
    Liu, Hai-Min
    Cheng, Hui
    Yang, Zhen
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2017, 5 (07): : 5713 - 5722
  • [8] ATR-IR spectroscopy for rapid quantification of water content in deep eutectic solvents
    Elderderi, Suha
    Leman-Loubiere, Charlotte
    Wils, Laura
    Henry, Sandra
    Bertrand, Dominique
    Byrne, Hugh J.
    Chourpa, Igor
    Enguehard-Gueiffier, Cecile
    Munnier, Emilie
    Elbashir, Abdalla A.
    Boudesocque-Delaye, Leslie
    Bonnier, Franck
    JOURNAL OF MOLECULAR LIQUIDS, 2020, 311
  • [9] Good vibrations: understanding deep eutectic solvents through the lens of vibrational spectroscopy
    Araujo, Catarina F.
    Abranches, Dinis O.
    Coutinho, Joao A. P.
    Vaz, Pedro D.
    Ribeiro-Claro, Paulo
    Nolasco, Mariela M.
    APPLIED SPECTROSCOPY REVIEWS, 2025, 60 (02) : 137 - 192
  • [10] Understanding the Water Structures in Deep Eutectic Solvents by Near-infrared Spectroscopy
    Wang, Yan
    Cai, Wengsheng
    Shao, Xueguang
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2023, 44 (06):