Cooling solutions in an operational data centre: A case study

被引:70
|
作者
Fakhim, B. [1 ]
Behnia, M. [1 ]
Armfield, S. W. [1 ]
Srinarayana, N. [1 ]
机构
[1] Univ Sydney, Sch Aerospace Mech & Mechatron Engn, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会;
关键词
Data centre; Cooling; Numerical simulation; Air-conditioning; Server rack;
D O I
10.1016/j.applthermaleng.2011.03.025
中图分类号
O414.1 [热力学];
学科分类号
摘要
The rapid growth in data centres large computing infrastructures containing vast quantities of data processing and storage equipment has resulted in their consumption of up to 100 times more energy per square metre than office accommodation. The decrease in processing server sizes and the more efficient use of space and server processing are challenging data centre facilities to provide more power and cooling, significantly increasing energy demands. Energy consumption of data centres can be severely and unnecessarily high due to inadequate localised cooling and densely packed server rack layouts. However, as heat dissipation in data centres rises by orders of magnitude, inefficiencies such as air recirculation causing hot spots and flow short-circuiting will have a significant impact on the thermal manageability and energy efficiency of the cooling infrastructure. Therefore, an efficient thermal management of high-powered electronic equipment is a significant challenge for cooling of data centres. To highlight the importance of some of these issues, in this project, an operational data centre has been studied. Field measurements of temperature have been performed. Numerical analysis of flow and temperature fields is conducted in order to evaluate the thermal behaviour of the data centre. A number of undesirable hot spots have been identified. To rectify the problem, a few practical design and remedial solutions to improve the cooling effectiveness have been proposed and examined to allow a reduced air-conditioning power requirement. The findings lead to a better understanding of the cooling issues and the respective proposed solutions allow an improved design for future data centres. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2279 / 2291
页数:13
相关论文
共 50 条
  • [11] Towards Joint Optimization Over ICT and Cooling Systems in Data Centre: A Survey
    Zhang, Weiwen
    Wen, Yonggang
    Wong, Yew Wah
    Toh, Kok Chuan
    Chen, Chiu-Hao
    IEEE COMMUNICATIONS SURVEYS AND TUTORIALS, 2016, 18 (03): : 1596 - 1616
  • [12] The Analysis of Modifications in Cooling Systems for High-Performance Data Centers. A Case Study
    Rusowicz, Artur
    Rucinski, Adam
    Laskowski, Rafal
    10TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (10TH ICEE), 2017,
  • [13] The effects of operational conditions of the desiccant wheel on the performance of desiccant cooling cycles
    Heidarinejad, Ghassem
    Pasdarshahri, Hadi
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2416 - 2423
  • [14] Desiccant cooling at the University of Lincoln: A case study
    Halliday, SP
    Beggs, CB
    INDOOR AND BUILT ENVIRONMENT, 2004, 13 (04) : 277 - 285
  • [15] Sustainable cooling solutions for building environments: A comprehensive study of earth-air cooling systems
    Bhandari, Ramesh
    ADVANCES IN MECHANICAL ENGINEERING, 2024, 16 (09)
  • [16] Potential of air-side economizers for data center cooling: A case study for key Australian cities
    Siriwardana, Jayantha
    Jayasekara, Saliya
    Halgamuge, Saman K.
    APPLIED ENERGY, 2013, 104 : 207 - 219
  • [17] Operational results of an intermittent absorption cooling unit
    El-Ghalban, AR
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (09) : 825 - 835
  • [18] Numerical study of operational processes in a GOx-kerosene rocket engine with liquid film cooling
    Strokach, Evgenij A.
    Borovik, Igor N.
    Bazarov, Vladimir G.
    Haidn, Oscar J.
    PROPULSION AND POWER RESEARCH, 2020, 9 (02) : 132 - 141
  • [19] Determination of heating and cooling day data for broiler housing: Isparta case
    Atilgan, Atilgan
    Yucel, Ali
    Oz, Hasan
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2012, 10 (3-4): : 353 - 356
  • [20] Operational Enhancement of Electric Drives by Advanced Cooling Technologies
    Groschup, Benedikt
    Nell, Martin
    Hameyer, Kay
    2019 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DAGNOSIS (WEMDCD), VOL 1, 2019, : 65 - 70