On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification

被引:3
|
作者
Abdullah, Shahla M. [1 ,2 ]
Rachid, Shwan [3 ]
机构
[1] Univ Raparin, Coll Sci, Med Lab Sci Dept, Ranyia 46012, Sulaymaniyah, Iraq
[2] Koya Univ, Fac Sci & Hlth, Biol Dept, Koysanjaq 44023, Erbil, Iraq
[3] Charmo Univ, Charmo Ctr Res Training & Consultancy, Chamchamal 46023, Sulaymaniyah, Iraq
来源
MOLECULES | 2020年 / 25卷 / 05期
关键词
biosensor; molecular quantification; penicillin-binding protein; penicillin; Bocillin FL; antibiotics; ASSAY; MILK; CARBOXYPEPTIDASE; RESIDUES; REAGENT;
D O I
10.3390/molecules25051248
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work aimed to develop accurate, quick, and practical tools for the detection of residues of penicillin G antibiotic in biological and non-biological samples. The assays were developed based on the binding mechanism of beta -lactam to penicillin-binding proteins; samples of different concentrations of penicillin G were incubated with in vitro expressed 6X-Histidine-tagged soluble penicillin-binding protein (PBP2x*) of Streptococcus pneumoniae (S. pneumoniae), whereby penicillin G in samples specifically binds to PBP2x*. The fluorescent-labeled beta -lactam analogue Bocillin FL was used as a competent substrate, and two different routes estimated the amounts of the penicillin G. The first route was established based on the differences in the concentration of non-bounded Bocillin FL molecules within the reactions while using a real-time polymerase chain reaction (PCR)-based method for fluorescence detection. The second route depended on the amount of the relative intensity of Bocillin FL bounded to Soluble PBP-2x*, being run on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-page), visualized by a ChemiDoc-It((R))2 Imager, and quantified based on the fluorescence affinity of the competent substrate. While both of the methods gave a broad range of linearity and high sensitivity, the on column based real-time method is fast, non-time consuming, and highly sensitive. The method identified traces of antibiotic in the range 0.01-0.2 nM in addition to higher accuracy in comparison to the SDS-based detection method, while the sensitivity of the SDS-based method ranged between 0.015 and 2 mu M). Thus, the on column based real time assay is a fast novel method, which was developed for the first time based on the binding inhibition of a fluorescence competitor material and it can be adapted to screen traces of penicillin G in any biological and environmental samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Characterization and food application of a potentiometric biosensor measuring β-lactam antibiotics
    Park, IS
    Kim, DK
    Kim, N
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2004, 14 (04) : 698 - 706
  • [22] Real-Time Monitoring and Quantification of Underwater Superhydrophobicity
    Smyrnakis, Athanasios
    Ioannou, Dimosthenis
    Ellinas, Kosmas
    Tserepi, Angeliki
    Gogolides, Evangelos
    ADVANCED MATERIALS INTERFACES, 2022, 9 (04)
  • [23] Real-time small molecule binding detection using a label-free photonic crystal biosensor
    Guo, Yunbo
    Ye, Jing Yong
    Huang, Baohua
    McNerny, Daniel
    Thomas, Thommey P.
    Baker, James R., Jr.
    Norris, Theodore B.
    FRONTIERS IN PATHOGEN DETECTION: FROM NANOSENSORS TO SYSTEMS, 2010, 7553
  • [24] Fluorescent antibiotics for real-time tracking of pathogenic bacteria
    Lu Miao
    Weiwei Liu
    Qinglong Qiao
    Xiaolian Li
    Zhaochao Xu
    Journal of Pharmaceutical Analysis, 2020, 10 (05) : 444 - 451
  • [25] Fluorescent antibiotics for real-time tracking of pathogenic bacteria
    Miao, Lu
    Liu, Weiwei
    Qiao, Qinglong
    Li, Xiaolian
    Xu, Zhaochao
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2020, 10 (05) : 444 - 451
  • [26] Evaluation of quantification methods for real-time PCR minor groove binding hybridization probe assays
    Durtschi, Jacob D.
    Stevenson, Jeffery
    Hymas, Weston
    Voelkerding, Karl V.
    ANALYTICAL BIOCHEMISTRY, 2007, 361 (01) : 55 - 64
  • [27] Real-time monitoring of antibody in Protein A column breakthrough
    Patil, Ujwal
    Crum, Mary
    Binh Vu
    Kourentzi, Katerina
    Willson, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [28] A Real-Time Column Array Processor Architecture for Images
    Zhao, Dongming
    Daut, David G.
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 1992, 2 (01) : 38 - 48
  • [29] A Column Store Engine for Real-Time Streaming Analytics
    Skidanov, Alex
    Papito, Anders J.
    Prout, Adam
    2016 32ND IEEE INTERNATIONAL CONFERENCE ON DATA ENGINEERING (ICDE), 2016, : 1287 - 1297
  • [30] A Column Generation Approach to Scheduling of Real-Time Networks
    Althaus, Ernst
    Hoffmann, Sebastian
    Kupilas, Joschka
    Thaden, Eike
    WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, WCECS 2012, VOL I, 2012, : 224 - 229