On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification

被引:3
|
作者
Abdullah, Shahla M. [1 ,2 ]
Rachid, Shwan [3 ]
机构
[1] Univ Raparin, Coll Sci, Med Lab Sci Dept, Ranyia 46012, Sulaymaniyah, Iraq
[2] Koya Univ, Fac Sci & Hlth, Biol Dept, Koysanjaq 44023, Erbil, Iraq
[3] Charmo Univ, Charmo Ctr Res Training & Consultancy, Chamchamal 46023, Sulaymaniyah, Iraq
来源
MOLECULES | 2020年 / 25卷 / 05期
关键词
biosensor; molecular quantification; penicillin-binding protein; penicillin; Bocillin FL; antibiotics; ASSAY; MILK; CARBOXYPEPTIDASE; RESIDUES; REAGENT;
D O I
10.3390/molecules25051248
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work aimed to develop accurate, quick, and practical tools for the detection of residues of penicillin G antibiotic in biological and non-biological samples. The assays were developed based on the binding mechanism of beta -lactam to penicillin-binding proteins; samples of different concentrations of penicillin G were incubated with in vitro expressed 6X-Histidine-tagged soluble penicillin-binding protein (PBP2x*) of Streptococcus pneumoniae (S. pneumoniae), whereby penicillin G in samples specifically binds to PBP2x*. The fluorescent-labeled beta -lactam analogue Bocillin FL was used as a competent substrate, and two different routes estimated the amounts of the penicillin G. The first route was established based on the differences in the concentration of non-bounded Bocillin FL molecules within the reactions while using a real-time polymerase chain reaction (PCR)-based method for fluorescence detection. The second route depended on the amount of the relative intensity of Bocillin FL bounded to Soluble PBP-2x*, being run on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-page), visualized by a ChemiDoc-It((R))2 Imager, and quantified based on the fluorescence affinity of the competent substrate. While both of the methods gave a broad range of linearity and high sensitivity, the on column based real-time method is fast, non-time consuming, and highly sensitive. The method identified traces of antibiotic in the range 0.01-0.2 nM in addition to higher accuracy in comparison to the SDS-based detection method, while the sensitivity of the SDS-based method ranged between 0.015 and 2 mu M). Thus, the on column based real time assay is a fast novel method, which was developed for the first time based on the binding inhibition of a fluorescence competitor material and it can be adapted to screen traces of penicillin G in any biological and environmental samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Development of a microelectrochemical biosensor for the real-time detection of choline
    Baker, Keeley L.
    Bolger, Fiachra B.
    Lowry, John P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 412 - 420
  • [12] An amperometric biosensor for real-time analysis of molecular recognition
    Ivnitski, D
    Wolf, T
    Solomon, B
    Fleminger, G
    Rishpon, J
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (01): : 27 - 32
  • [13] An enzymatic electrochemical biosensor for real-time nicotine detection
    Kuzmanovic, Uros
    Chen, Mingfu
    Tararina, Margarita
    Shu, Nicholas
    Balijepalli, Anant
    Zamani, Marjon
    Fan, Andy
    Klapperich, Catherine
    Allen, Karen
    Grinstaff, Mark
    Galagan, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [14] A novel biosensor for the real-time study of cell movement
    Hood, AS
    Neal, R
    Garland, J
    Alshukri, S
    Carr, R
    MEDICAL AND FIBER OPTIC SENSORS AND DELIVERY SYSTEMS, PROCEEDINGS OF, 1996, 2631 : 46 - 53
  • [15] Approaching near real-time biosensing: Microfluidic microsphere based biosensor for real-time analyte detection
    Cohen, Noa
    Sabhachandani, Pooja
    Golberg, Alexander
    Konry, Tania
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 454 - 460
  • [16] Noninvasive real-time quantification of nanoparticles in vivo
    不详
    NANOMEDICINE, 2012, 7 (06) : 804 - 805
  • [17] Real-time PCR for quantification of Streptococcus mutans
    Yano, A
    Kaneko, N
    Ida, H
    Yamaguchi, T
    Hanada, N
    FEMS MICROBIOLOGY LETTERS, 2002, 217 (01) : 23 - 30
  • [18] Real-time quantification of the proliferative state in astrocytomas
    Ricco, R
    Cimmino, A
    Renzulli, G
    Serio, G
    Lozupone, A
    Lettini, T
    Pece, A
    Giardina, C
    Delfino, VP
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 2000, 22 (03): : 213 - 217
  • [19] HBV DNA quantification by real-time PCR
    Plisek, S
    Pliskova, L
    Hrochova, K
    Stepanova, V
    JOURNAL OF HEPATOLOGY, 2003, 38 : 163 - 163
  • [20] Cytokine mRNA quantification by real-time PCR
    Stordeur, P
    Poulin, LF
    Craciun, L
    Zhou, L
    Schandené, L
    de Lavareille, A
    Goriely, S
    Goldman, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 259 (1-2) : 55 - 64