On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification

被引:3
|
作者
Abdullah, Shahla M. [1 ,2 ]
Rachid, Shwan [3 ]
机构
[1] Univ Raparin, Coll Sci, Med Lab Sci Dept, Ranyia 46012, Sulaymaniyah, Iraq
[2] Koya Univ, Fac Sci & Hlth, Biol Dept, Koysanjaq 44023, Erbil, Iraq
[3] Charmo Univ, Charmo Ctr Res Training & Consultancy, Chamchamal 46023, Sulaymaniyah, Iraq
来源
MOLECULES | 2020年 / 25卷 / 05期
关键词
biosensor; molecular quantification; penicillin-binding protein; penicillin; Bocillin FL; antibiotics; ASSAY; MILK; CARBOXYPEPTIDASE; RESIDUES; REAGENT;
D O I
10.3390/molecules25051248
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work aimed to develop accurate, quick, and practical tools for the detection of residues of penicillin G antibiotic in biological and non-biological samples. The assays were developed based on the binding mechanism of beta -lactam to penicillin-binding proteins; samples of different concentrations of penicillin G were incubated with in vitro expressed 6X-Histidine-tagged soluble penicillin-binding protein (PBP2x*) of Streptococcus pneumoniae (S. pneumoniae), whereby penicillin G in samples specifically binds to PBP2x*. The fluorescent-labeled beta -lactam analogue Bocillin FL was used as a competent substrate, and two different routes estimated the amounts of the penicillin G. The first route was established based on the differences in the concentration of non-bounded Bocillin FL molecules within the reactions while using a real-time polymerase chain reaction (PCR)-based method for fluorescence detection. The second route depended on the amount of the relative intensity of Bocillin FL bounded to Soluble PBP-2x*, being run on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-page), visualized by a ChemiDoc-It((R))2 Imager, and quantified based on the fluorescence affinity of the competent substrate. While both of the methods gave a broad range of linearity and high sensitivity, the on column based real-time method is fast, non-time consuming, and highly sensitive. The method identified traces of antibiotic in the range 0.01-0.2 nM in addition to higher accuracy in comparison to the SDS-based detection method, while the sensitivity of the SDS-based method ranged between 0.015 and 2 mu M). Thus, the on column based real time assay is a fast novel method, which was developed for the first time based on the binding inhibition of a fluorescence competitor material and it can be adapted to screen traces of penicillin G in any biological and environmental samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Impedimetric Biosignal Analysis and Quantification in a Real-Time Biosensor System
    Messing, Dean S.
    Ghindilis, Andrey
    Schwarzkopf, Kevin
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 2730 - 2734
  • [2] REAL-TIME DETECTION AND QUANTIFICATION OF DNA HYBRIDIZATION BY AN OPTICAL BIOSENSOR
    WATTS, HJ
    YEUNG, D
    PARKES, H
    ANALYTICAL CHEMISTRY, 1995, 67 (23) : 4283 - 4289
  • [3] A real-time biosensor for plant hormones
    Napier, Richard M.
    Badescu, George O.
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2009, 153A (02): : S212 - S212
  • [4] Real-Time Biomolecular Binding Detection Using a Sensitive Photonic Crystal Biosensor
    Guo, Yunbo
    Ye, Jing Yong
    Divin, Charles
    Huang, Baohua
    Thomas, Thommey P.
    Baker, James R., Jr.
    Norris, Theodore B.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5211 - 5218
  • [5] Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements
    Pflegerl, K
    Hahn, R
    Schallaun, E
    Josic, D
    Jungbauer, A
    JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (02): : 335 - 347
  • [6] Real-time quantification of methanol in plants using a hybrid alcohol oxidase-peroxidase biosensor
    Hasunuma, T
    Kuwabata, S
    Fukusaki, E
    Kobayashi, A
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1500 - 1506
  • [7] Real-time PCR assay for ultrasensitive quantification of DNA-binding proteins
    Hou, Peng
    Chen, Zaozao
    Ji, Meiju
    He, Nongyue
    Lu, Zuhong
    CLINICAL CHEMISTRY, 2007, 53 (04) : 581 - 586
  • [8] Towards the Development of a Real-time Insulin Biosensor
    Sen, Sanjana
    Crawley, Emily M.
    Gabriel, Kristin N.
    Fletcher, Madison H.
    Speciale, Gaetano
    Vincents, Bjarne
    Mo, Josh H.
    Safronyuk, Katrin
    Totoiu, Christian Alexander
    Majumdar, Sudipta
    Botvinick, Elliot L.
    Weiss, Gregory A.
    FASEB JOURNAL, 2018, 32 (01):
  • [9] A Novel Method for Real-Time Quantification of Radioligand Binding to Living Tumor Cells In Vitro
    Baeck, Tom
    Albertsson, Per
    Aneheim, Emma
    Hultborn, Ragnar
    Jacobsson, Lars
    Lindegren, Sture
    Palm, Stig
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2024, 39 (01) : 75 - 81
  • [10] Real-time investigation of antibiotics-induced oxidative stress and superoxide release in bacteria using an electrochemical biosensor
    Liu, Xiaobo
    Marrakchi, Mouna
    Jahne, Michael
    Rogers, Shane
    Andreescu, Silvana
    FREE RADICAL BIOLOGY AND MEDICINE, 2016, 91 : 25 - 33