On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification

被引:4
作者
Abdullah, Shahla M. [1 ,2 ]
Rachid, Shwan [3 ]
机构
[1] Univ Raparin, Coll Sci, Med Lab Sci Dept, Ranyia 46012, Sulaymaniyah, Iraq
[2] Koya Univ, Fac Sci & Hlth, Biol Dept, Koysanjaq 44023, Erbil, Iraq
[3] Charmo Univ, Charmo Ctr Res Training & Consultancy, Chamchamal 46023, Sulaymaniyah, Iraq
关键词
biosensor; molecular quantification; penicillin-binding protein; penicillin; Bocillin FL; antibiotics; ASSAY; MILK; CARBOXYPEPTIDASE; RESIDUES; REAGENT;
D O I
10.3390/molecules25051248
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work aimed to develop accurate, quick, and practical tools for the detection of residues of penicillin G antibiotic in biological and non-biological samples. The assays were developed based on the binding mechanism of beta -lactam to penicillin-binding proteins; samples of different concentrations of penicillin G were incubated with in vitro expressed 6X-Histidine-tagged soluble penicillin-binding protein (PBP2x*) of Streptococcus pneumoniae (S. pneumoniae), whereby penicillin G in samples specifically binds to PBP2x*. The fluorescent-labeled beta -lactam analogue Bocillin FL was used as a competent substrate, and two different routes estimated the amounts of the penicillin G. The first route was established based on the differences in the concentration of non-bounded Bocillin FL molecules within the reactions while using a real-time polymerase chain reaction (PCR)-based method for fluorescence detection. The second route depended on the amount of the relative intensity of Bocillin FL bounded to Soluble PBP-2x*, being run on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-page), visualized by a ChemiDoc-It((R))2 Imager, and quantified based on the fluorescence affinity of the competent substrate. While both of the methods gave a broad range of linearity and high sensitivity, the on column based real-time method is fast, non-time consuming, and highly sensitive. The method identified traces of antibiotic in the range 0.01-0.2 nM in addition to higher accuracy in comparison to the SDS-based detection method, while the sensitivity of the SDS-based method ranged between 0.015 and 2 mu M). Thus, the on column based real time assay is a fast novel method, which was developed for the first time based on the binding inhibition of a fluorescence competitor material and it can be adapted to screen traces of penicillin G in any biological and environmental samples.
引用
收藏
页数:13
相关论文
共 40 条
[1]   Receptor-based screening assays for the detection of antibiotics residues - A review [J].
Ahmed, Saeed ;
Ning, Jianan ;
Cheng, Guyue ;
Ahmad, Ijaz ;
Jun Li ;
Liu Mingyue ;
Wei Qu ;
Iqbal, Mujahid ;
Shabbir, M. A. B. ;
Yuan, Zonghui .
TALANTA, 2017, 166 :176-186
[2]   A putative low-molecular-mass penicillin-binding protein (PBP) of Mycobacterium smegmatis exhibits prominent physiological characteristics of DD-carboxypeptidase and beta-lactamase [J].
Bansal, Ankita ;
Kar, Debasish ;
Murugan, Rajagopal A. ;
Mallick, Sathi ;
Dutta, Mouparna ;
Pandey, Satya Deo ;
Chowdhury, Chiranjit ;
Ghosh, Anindya S. .
MICROBIOLOGY-SGM, 2015, 161 :1081-1091
[3]   Allostery, Recognition of Nascent Peptidoglycan, and Cross-linking of the Cell Wall by the Essential Penicillin-Binding Protein 2x of Streptococcus pneumoniae [J].
Bernardo-Garcia, Noelia ;
Mahasenan, Kiran V. ;
Batuecas, Maria T. ;
Lee, Mijoon ;
Hesek, Dusan ;
Petrackova, Denisa ;
Doubravova, Linda ;
Branny, Pavel ;
Mobashery, Shahriar ;
Hermoso, Juan A. .
ACS CHEMICAL BIOLOGY, 2018, 13 (03) :694-702
[4]   Detection and fate of antibiotic resistant bacteria in wastewater treatment plants: A review [J].
Bouki, Chryssa ;
Venieri, Danae ;
Diamadopoulos, Evan .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2013, 91 :1-9
[5]   β-Lactams and β-Lactamase Inhibitors: An Overview [J].
Bush, Karen ;
Bradford, Patricia A. .
COLD SPRING HARBOR PERSPECTIVES IN MEDICINE, 2016, 6 (08)
[6]   Development of an optical biosensor assay for detection of β-lactam antibiotics in milk using the penicillin-binding protein 2x [J].
Cacciatore, G ;
Petz, M ;
Rachid, S ;
Hakenbeck, R ;
Bergwerff, AA .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :105-115
[7]   Rational design of a novel fluorescent biosensor for β-lactam antibiotics from a class A β-lactamase [J].
Chan, PH ;
Liu, HB ;
Chen, YW ;
Chan, KC ;
Tsang, CW ;
Leung, YC ;
Wong, KY .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (13) :4074-4075
[8]   High-Throughput Screening for Novel Inhibitors of Neisseria gonorrhoeae Penicillin-Binding Protein 2 [J].
Fedarovich, Alena ;
Djordjevic, Kevin A. ;
Swanson, Shauna M. ;
Peterson, Yuri K. ;
Nicholas, Robert A. ;
Davies, Christopher .
PLOS ONE, 2012, 7 (09)
[9]   Biosensors for Monitoring Airborne Pathogens [J].
Fronczek, Christopher F. ;
Yoon, Jeong-Yeol .
JALA, 2015, 20 (04) :390-410
[10]   Screening of penicillin residues in milk by a surface plasmon resonance-based biosensor assay: comparison of chemical and enzymatic sample pre-treatment [J].
Gaudin, V ;
Fontaine, J ;
Maris, P .
ANALYTICA CHIMICA ACTA, 2001, 436 (02) :191-198