Post-fire resistance of internally ring stiffened high performance concrete filled steel tube columns

被引:30
作者
Ekmekyapar, Talha [1 ]
Alhatmey, Ihssan A. H. [1 ]
机构
[1] Gaziantep Univ, Civil Engn Dept, TR-27310 Gaziantep, Turkey
关键词
CFST columns; Fire exposure; Post-fire resistance; Internal rings; Experiments; HIGH-STRENGTH CONCRETE; RESTRAINED COMPOSITE COLUMNS; TUBULAR SHORT COLUMNS; MECHANICAL-PROPERTIES; FIRE RESISTANCE; COMPRESSIVE BEHAVIOR; RESIDUAL STRENGTH; DESIGN; EXPOSURE; TEMPERATURES;
D O I
10.1016/j.engstruct.2019.01.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Use of composite construction is increasing exponentially across the world, since such structures offer the combined benefits of constituent materials and provide cost effective solutions. Concrete filled steel tube (CFST) columns have been proven to be a very efficient way of composite construction. Although the behaviour of CFST columns under many different loading scenarios has been well detailed, a search of the literature revealed few studies on the post-fire resistance of these members. This paper gives an account of internally ring stiffening of CFST columns with the aim of advancing their post-fire resistance. To this end, CFST columns with and without internal rings were subjected to a standard fire exposure. To address their post-fire performance, fire exposed specimens and counterparts without fire exposure (in total 30 specimens) were tested under concentric compression to failure. CFST column specimens were manufactured using self-compacted high performance concrete to acquire key knowledge which could be exploited in highly stressed engineering structures. Experimental results indicate that with a proper design, internal rings are very efficient in providing high post-fire resistances. Some specific configurations achieved post-fire resistances greater than that of the capacities of classical CFST counterparts without fire exposure. Accordingly, it is shown that internal rings have the potential to eliminate the need for external coating or any other expensive fire protection measure to circumvent post-fire design concerns. The findings of this research provide novel insights and offer cost effective solutions to improve the performance of CFST columns under ambient temperature and after fire exposure.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 57 条
[1]   Shear strength and behavior of tubed reinforced and steel reinforced concrete (TRC and TSRC) short columns [J].
Abdullah, Jasim Ali ;
Zhang Sumei ;
Liu Jiepeng .
THIN-WALLED STRUCTURES, 2010, 48 (03) :191-199
[2]   Performance of lightweight aggregate and self-compacted concrete-filled steel tube columns [J].
AL-Eliwi, Baraa J. M. ;
Ekmekyapar, Talha ;
Faraj, Radhwan H. ;
Gogus, M. Tolga ;
AL-Shaar, Ahmed A. M. .
STEEL AND COMPOSITE STRUCTURES, 2017, 25 (03) :299-314
[3]  
American Society for Testing and Materials (Astm), 2016, ASTM E119-16
[4]  
[Anonymous], 2012, 834 ISO
[5]  
[Anonymous], 2019, A37019 ASTM
[6]  
[Anonymous], 2016, E8E8M16A1 ASTM
[7]   Behavior of ECC-encased CFST columns under axial compression [J].
Cai, Jingming ;
Pan, Jinlong ;
Li, Xiaopeng .
ENGINEERING STRUCTURES, 2018, 171 :1-9
[8]  
CEN, 2009, 1991122002 CEN BS
[9]   Effects of external confinement on structural performance of concrete-filled steel tubes [J].
Dong, C. X. ;
Kwan, A. K. H. ;
Ho, J. C. M. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 132 :72-82
[10]   Concrete filled double circular steel tube (CFDCST) stub columns [J].
Ekmekyapar, Talha ;
Al-Eliwi, Baraa J. M. .
ENGINEERING STRUCTURES, 2017, 135 :68-80