Super resolution SPECT reconstruction with non-uniform attenuation

被引:8
|
作者
Yan, Ziye [1 ,2 ]
Lu, Yao [2 ]
Wen, Junhai [1 ]
Li, Cuifen [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Dept Biomed Engn, Beijing 100081, Peoples R China
[2] Beijing Inst Technol, Sch Comp Sci & Technol, Beijing Lab Intelligent Informat Technol, Beijing 100081, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
SPECT; Reconstruction; Super resolution; Non-uniform attenuation; DETECTOR RESPONSE; SUPERRESOLUTION; MRI;
D O I
10.1016/j.compbiomed.2012.02.005
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, based on Novikov's explicit inversion formula for the attenuated Radon transform, we present a super resolution SPECT reconstruction algorithm with compensation for non-uniform attenuation. Unlike the former methods improving the medical image resolution via super resolution (SR) in the reconstructed image, the proposed method apply the SR algorithm in the low resolution (LR) sinogram, which needs only 1-D shift of the detector, and the PSF is easy to obtain. Simulation results show that our reconstruction algorithm is effective. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 50 条
  • [1] Analytical Cone Beam SPECT Reconstruction with Non-uniform Attenuation
    Wen, Junhai
    Chen, Yunbin
    Wang, Li
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2136 - 2139
  • [2] Rebinning Methods for Cone Beam SPECT Reconstruction with Non-uniform Attenuation
    Chen, Yunbin
    Wen, Junhai
    Wang, Li
    Hu, Peng
    Zhang, Hao
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 337 - 340
  • [3] NON-UNIFORM ATTENUATION AND SCATTER CORRECTION IN SPECT
    SINGH, M
    HORNE, M
    MANEVAL, D
    AMARTEY, J
    BRECHNER, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 767 - 771
  • [4] FAST ANALYTICAL RECONSTRUCTION OF GATED CARDIAC SPECT WITH NON-UNIFORM ATTENUATION COMPENSATION
    Fan, Yi
    Lu, Hongbing
    Hao, Chongyang
    Liang, Zhengrong
    Zhou, Zhiming
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2007, 7 (01) : 87 - 104
  • [5] The effect of de-noising for analytical SPECT reconstruction with non-uniform attenuation
    Li, Yincen
    Wen, Junhai
    Kong, Lingkai
    Wang, Wei
    Yan, Qi
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 837 - 842
  • [6] Analytical reconstruction for helical cone-beam SPECT with non-uniform attenuation correction
    Huang, Qiu
    Zeng, Gengsheng L.
    Gullberg, Grant T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1856 - 1859
  • [7] Analytical solution to Cone-beam SPECT reconstruction with non-uniform attenuation and distance-dependent resolution variation
    Zhang, Hao
    Wen, Junhai
    Yang, Jing
    Hu, Peng
    Liang, Zhengrong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] SPECT Reconstruction with Non-uniform Attenuation from Highly Under-sampled Projection Data
    Li, Cuifen
    Wen, Junhai
    Zhang, Kangping
    Shi, Donghao
    Dong, Haixiang
    Li, Wenxiao
    Liang, Zhengrong
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [9] Image reconstruction for discontinuous objects with half-data knowledge in SPECT with non-uniform attenuation
    Sidky, EY
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2919 - 2922
  • [10] The de-noising methods for SPECT reconstruction with non-uniform attenuation based on wavelet transform
    Wen, Junhai
    Li, Yincen
    Wang, Wei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 843 - 849