NUMERICAL ANALYSIS OF AN IMMUNOCHROMATOGRAPHIC TEST STRIP READER IN ABUSED DRUGS SCREENING

被引:2
作者
Chang, Yan-Zin [2 ,4 ]
Yao, Wen-Fa [3 ]
Hsiung, Kuang-Pin [3 ]
Chiou, Ming-Shen [1 ]
Li, Hsing-Ya [1 ]
机构
[1] Natl United Univ, Dept Chem Engn, Miaoli 360, Taiwan
[2] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[3] Taiwan Unison Biotechnol Inc, Off Res & Dev, Hsinchu, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Clin Lab, Drug Testing Ctr, Taichung, Taiwan
关键词
drug screening; drugs of abuse; immunochromatographic assays; point of care testing; test strip reader; LAYER IMMUNOAFFINITY CHROMATOGRAPHY; QUANTITATION; PROTEIN; ASSAY;
D O I
10.1080/15321819.2011.618862
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A point-of-care immunoassay strip reader, Uniscan (TM), was applied to detect methamphetamine, opiate, and marijuana in human urine by providing numerical apparent drug concentrations. Calibration curves were determined by a nonlinear regression. The cutoff was verified using spiked controls. Clinical samples were analyzed and compared with enzyme multiplied immunoassay technique (EMIT). The discrepant results were confirmed by gas chromatography-mass spectrometry (GC-MS). The impacts of interference and cross-reactivity were determined for numerous compounds. The coefficients of the calibration curves had a high correlation coefficient. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and total recovery all had high values for spiked controls. For the 19 discrepant results of clinical samples, GC-MS confirmed that Uniscan and EMIT were correct for 11 and eight samples, respectively. For both methamphetamine and opiate, Uniscan had a lower false positive rate, a higher true negative rate, and a higher total recovery rate than EMIT For marijuana, Uniscan had a higher true positive rate and a lower false negative rate than EMIT The Uniscan performed excellently when compared to EMIT It is advantageous for Uniscan to interpret the test result based on digital read-out, rather than subjective visual judgment.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 50 条
  • [41] Development and application of a rapid semiquantitative immunochromatographic test strip to detect white spot syndrome virus
    Sheng, Xiuzhen
    Tang, Qian
    Zhang, Ling
    Tang, Xiaoqian
    Xing, Jing
    Zhan, Wenbin
    [J]. AQUACULTURE, 2018, 495 : 773 - 779
  • [42] Mathematical modeling of immunochromatographic test systems in a competitive format: Analytical and numerical approaches
    Sotnikov, Dmitriy, V
    Byzova, Nadezhda A.
    Zvereva, Elena A.
    Bartosh, Anastasia, V
    Zherdev, Anatoly, V
    Dzantiev, Boris B.
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2020, 164
  • [43] Development of a rapid immunochromatographic strip test for the detection of porcine epidemic diarrhea virus specific SIgA in colostrum
    Liu, Jianbo
    Gao, Ran
    Shi, Hongyan
    Cong, Guangyi
    Chen, Jianfei
    Zhang, Xin
    Shi, Da
    Cao, Liyan
    Wang, Xiaobo
    Zhang, Jialin
    Ji, Zhaoyang
    Jing, Zhaoyang
    Feng, Li
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2020, 279
  • [44] Fluorescent immunochromatographic test strip for therapeutic drug monitoring of methotrexate with high sensitivity and wide dynamic range
    Zhu, Zhongjie
    Zhang, Yu
    Xue, Jinxia
    Kong, Jing
    Huang, Ling
    Ouyang, Hui
    Fu, Zhifeng
    He, Yong
    [J]. MICROCHIMICA ACTA, 2023, 190 (09)
  • [45] Development of an Immunochromatographic Test Strip for Rapid Simultaneous Detection of Enrofloxacin and Ofloxacin in Tissue of Chicken Muscle and Pork
    Wu, Yuchen
    Guo, Shuang
    Dong, Qing
    Song, Yuzhen
    [J]. FOOD ANALYTICAL METHODS, 2016, 9 (10) : 2807 - 2813
  • [46] Multicolor immunochromatographic strip test based on gold nanoparticles for the determination of aflatoxin B1 and fumonisins
    Di Nardo, Fabio
    Baggiani, Claudio
    Giovannoli, Cristina
    Spano, Giulia
    Anfossi, Laura
    [J]. MICROCHIMICA ACTA, 2017, 184 (05) : 1295 - 1304
  • [47] Development of a simple and rapid immunochromatographic strip test for diarrhea-causative porcine rotavirus in swine stool
    Kang, J. H.
    Kwon, D. H.
    Chung, T. W.
    Kim, Y. D.
    Lee, H. G.
    Kim, J. W.
    Choe, I. S.
    Kim, K. -W.
    Lim, J. S.
    Song, E. Y.
    Kim, C. -H.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2007, 146 (1-2) : 74 - 79
  • [48] Simultaneous detection of phenacetin and paracetamol using ELISA and a gold nanoparticle-based immunochromatographic test strip
    Yao, Jingjing
    Xu, Xinxin
    Liu, Liqiang
    Kuang, Hua
    Wang, Zhengyou
    Xu, Chuanlai
    [J]. ANALYST, 2021, 146 (20) : 6228 - 6238
  • [49] Development of a Class-specific Immunochromatographic Strip Test for the Rapid Detection of Organophosphorus Pesticides With a Thiophosphate Group
    Su, Jing
    Yang, Hui
    Chen, Jialei
    Yin, Huancai
    Tang, Ruihua
    Xie, Yuwei
    Song, Kai
    Huyan, Ting
    Wang, Hua
    Wang, Wei
    Xue, Xiaoping
    [J]. HYBRIDOMA, 2010, 29 (04): : 291 - 299
  • [50] A Colloidal Gold Nanoparticle-Based Immunochromatographic Test Strip for Rapid and Convenient Detection of Staphylococcus Aureus
    Niu, Kaili
    Zheng, Xiaoping
    Huang, Chusen
    Xu, Kuan
    Zhi, Yuan
    Shen, Hebai
    Jia, Nengqin
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (07) : 5151 - 5156