Femoral revision with the Wagner tapered stem

被引:66
作者
Regis, D. [1 ]
Sandri, A. [1 ]
Bonetti, I. [1 ]
Braggion, M. [1 ]
Bartolozzi, P. [1 ]
机构
[1] Univ Integrata, Azienda Osped, Dept Orthopaed, I-37134 Verona, Italy
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2011年 / 93B卷 / 10期
关键词
TOTAL HIP-ARTHROPLASTY; POROUS-COATED STEMS; FOLLOW-UP; DISTAL FIXATION; BONE LOSS; REPLACEMENT; PROSTHESIS; COMPONENTS; FRACTURES; DISLOCATION;
D O I
10.1302/0301-620X.93B10.25927
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision after failed femoral components may be technically demanding due to loss of periprosthetic bone. This retrospective study evaluated the long-term results of femoral revision using the cementless Wagner Self-Locking stem. Between 1992 and 1998, 68 consecutive hips in 66 patients underwent femoral revision using this implant. A total of 25 patients died from unrelated causes without further revision; the remaining 41 hips in 41 patients (12 men and 29 women) with a mean age of 61 years (29 to 80) were reviewed at a mean follow-up of 13.9 years (10.4 to 15.8). A transfemoral approach was used in 32 hips. A total of five stems required further revision because of infection in two, progressive subsidence in two and recurrent dislocation in one. Four hips had dislocated and eight stems had subsided >= 10 mm. The mean Harris hip score improved from 33 points pre-operatively to 75 points at final follow-up (p < 0.001). In all, 33 stems (91.7%) showed radiological signs of stable bone fixation. The cumulative survival rates at 15.8 years with femoral revision for any reason and for stem failure as the endpoints were 92.0% (95% confidence interval (CI) 86.0% to 98.4%) and 96.6% (95% CI 92.2% to 100%), respectively. The survivorship with revision and >= 10 mm migration of the stem as the endpoint was 83.6% (95% CI 76.6% to 91.4%). This study shows quite good survival and moderate clinical outcome when using a monoblock tapered titanium stem for supporting the regeneration of bone in complex revision hip surgery.
引用
收藏
页码:1320 / 1326
页数:7
相关论文
共 55 条
[1]   Proximal femoral allograft-prosthesis composites in revision hip replacement A 12-YEAR FOLLOW-UP STUDY [J].
Babis, G. C. ;
Sakellariou, V. I. ;
O'Connor, M. I. ;
Hanssen, A. D. ;
Sim, F. H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (03) :349-355
[2]  
Bartolozzi P, 1998, ITAL J ORTHOP TRAUMA, V24, P269
[3]   Femoral revision - Distal fixation with fluted, tapered grit-blasted stems [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :142-146
[4]  
Böhm P, 2001, J BONE JOINT SURG AM, V83A, P1023
[5]  
Böhm P, 2004, CLIN ORTHOP RELAT R, P148
[6]  
Boisgard S, 2001, REV CHIR ORTHOP, V87, P147
[7]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[8]  
BUDASSI R, 2003, ORTOP TRAUMATOL SERT, V45, P19
[9]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[10]  
Cech O, 2001, Acta Chir Orthop Traumatol Cech, V68, P148