AC and DC Corona/Ozone-induced Ageing of HTV Silicone Rubber

被引:54
作者
Ma, Bin [1 ]
Gubanski, Stanislaw M. [1 ]
Hillborg, Henrik [2 ]
机构
[1] Chalmers Univ Technol, SE-41296 Gothenburg, Sweden
[2] ABB Corp Res, Power Technol, SE-72178 Vasteras, Sweden
关键词
Outdoor insulation; composite insulation; silicone rubber; corona treatment; ozone treatment; electric conduction; dielectric response; mechanical strength; ageing; HYDROPHOBICITY RECOVERY; PARTIAL DISCHARGES; POLYDIMETHYLSILOXANE; INSULATORS; SURFACE; EXPOSURE; AIR;
D O I
10.1109/TDEI.2011.6118636
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
On the way of making efforts to standardize the selection of polymeric materials for high voltage outdoor environments, the resistance to corona and ozone has been recognized as one among twelve parameters to be evaluated within the CIGRE Working Group D1.14 [1]. Our previous related work reported on the evaluation of the resistance of five commercially available polymeric materials to ac corona-ozone treatment, according to the test procedure recommended by this Working Group. With the same test arrangement in use, this report focuses on comparing the influences of ac and dc corona-ozone exposures on high temperature vulcanized (HTV) silicone rubbers. For this purpose, two types of HTV materials were used, each one characterized by different resistivity levels and tensile strength. For defining the treatment conditions, the ac and dc coronas were characterized by measuring the associated discharge current as well as the power released from the electrode. The intensity of ac corona discharge was found to be higher than that of dc corona, the latter being controlled by electrostatic charging of the treated polymeric surfaces, which also resulted in significant differences of the resulting ozone concentration. Experimental investigations after the treatments concentrated on evaluating dielectric properties (e. g. surface and volume resistivities, dielectric response (DR)), mechanical properties (e. g. tensile strength and elongation at break), as well as chemical and structural analyses (e. g. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR)). Results obtained from the measurements of dielectric properties indicated a strong sensitivity of surface resistivity to the treatments, though the impact of the dc corona remained less pronounced. On the other hand, the dielectric response and volume resistivity did not exhibit a high susceptibility to the exposure. No substantial differences were also found among the ac and dc corona treated samples as regards the mechanical properties. The XPS and FTIR analyses revealed proofs of surface oxidation for the samples treated by ac corona, while the samples treated by dc corona showed much less tendency for oxidation.
引用
收藏
页码:1984 / 1994
页数:11
相关论文
共 35 条
[1]   Effect of mineral oil on flashover voltage of HTV silicone rubber under AC corona ageing: from the view of trap level distribution [J].
Yu, Yu ;
Wang, Ke ;
Yang, Yan ;
Li, Gang ;
Wu, Guangning ;
Li, Jinzhong ;
Gao, Bo .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (23) :5498-5504
[2]   Surface Charge Decay on HTV Silicone Rubber: Effect of Material Treatment by Corona Discharges [J].
Kumara, Sarath ;
Ma, Bin ;
Serdyuk, Yuriy V. ;
Gubanski, Stanislaw M. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) :2189-2195
[3]   Viability of Fillers in HTV Silicone Rubber in the AC and DC Inclined Plane Tests [J].
Ghunem, Refat Atef ;
Ilhan, Suat ;
Uckol, Halil Ibrahim ;
Tuzun, Didem ;
Hadjadj, Yazid .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (06) :2144-2151
[4]   Influence of AC and DC corona on high temperature vulcanized silicone rubber [J].
Gao Y. ;
Wang J. ;
Liang X. ;
Yan Z. ;
Liu Y. .
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2016, 36 (01) :274-284
[5]   Interpreting Surface Degradation of HTV Silicone Rubber Filled with Micro/Nano-Silica Under AC and DC Voltages [J].
Akbar, Muhammad ;
Ullah, Rahmat ;
Abdul Karim, M. R. .
JOURNAL OF ELECTRONIC MATERIALS, 2020, 49 (09) :5399-5410
[6]   Effect of Acidic-fog on performances of HTV silicone rubber with AC energized [J].
Huang, Huan ;
Liang, Tian ;
Li, Bo ;
Ma, Xiaodan ;
Mao, Xianyin ;
Lu, Qianyong .
ENGINEERING FAILURE ANALYSIS, 2022, 132
[7]   Effect of corona intensity on the hydrophobicity recovery characteristics of HTV silicone rubber [J].
Ding, Lijian ;
Liang, Ying ;
Tu, Youping ;
Wang, Wei ;
Li, C. R. .
ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, :90-90
[8]   Interpreting Surface Degradation of HTV Silicone Rubber Filled with Micro/Nano-Silica Under AC and DC Voltages [J].
Muhammad Akbar ;
Rahmat Ullah ;
M. R. Abdul Karim .
Journal of Electronic Materials, 2020, 49 :5399-5410
[9]   Resistance to Corona Discharge of HTV Silicone Rubber Surface Layers Fluorinated at Different Temperatures [J].
An, Zhenlian ;
Gu, Xiaoxiao ;
Shen, Ruochen ;
Tang, Yujiao ;
Zheng, Feihu ;
Zhang, Yewen ;
Yang, Long .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (02) :729-740
[10]   Effects of AC and DC Corona on the Surface Properties of Silicone Rubber: Characterization by Contact Angle Measurements and XPS High Resolution Scan [J].
Bao, Weining ;
Liang, Xidong ;
Liu, Yingyan ;
Gao, Yanfeng ;
Wang, Jiafu .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (05) :2911-2919