AC and DC Corona/Ozone-induced Ageing of HTV Silicone Rubber

被引:52
|
作者
Ma, Bin [1 ]
Gubanski, Stanislaw M. [1 ]
Hillborg, Henrik [2 ]
机构
[1] Chalmers Univ Technol, SE-41296 Gothenburg, Sweden
[2] ABB Corp Res, Power Technol, SE-72178 Vasteras, Sweden
关键词
Outdoor insulation; composite insulation; silicone rubber; corona treatment; ozone treatment; electric conduction; dielectric response; mechanical strength; ageing; HYDROPHOBICITY RECOVERY; PARTIAL DISCHARGES; POLYDIMETHYLSILOXANE; INSULATORS; SURFACE; EXPOSURE; AIR;
D O I
10.1109/TDEI.2011.6118636
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
On the way of making efforts to standardize the selection of polymeric materials for high voltage outdoor environments, the resistance to corona and ozone has been recognized as one among twelve parameters to be evaluated within the CIGRE Working Group D1.14 [1]. Our previous related work reported on the evaluation of the resistance of five commercially available polymeric materials to ac corona-ozone treatment, according to the test procedure recommended by this Working Group. With the same test arrangement in use, this report focuses on comparing the influences of ac and dc corona-ozone exposures on high temperature vulcanized (HTV) silicone rubbers. For this purpose, two types of HTV materials were used, each one characterized by different resistivity levels and tensile strength. For defining the treatment conditions, the ac and dc coronas were characterized by measuring the associated discharge current as well as the power released from the electrode. The intensity of ac corona discharge was found to be higher than that of dc corona, the latter being controlled by electrostatic charging of the treated polymeric surfaces, which also resulted in significant differences of the resulting ozone concentration. Experimental investigations after the treatments concentrated on evaluating dielectric properties (e. g. surface and volume resistivities, dielectric response (DR)), mechanical properties (e. g. tensile strength and elongation at break), as well as chemical and structural analyses (e. g. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR)). Results obtained from the measurements of dielectric properties indicated a strong sensitivity of surface resistivity to the treatments, though the impact of the dc corona remained less pronounced. On the other hand, the dielectric response and volume resistivity did not exhibit a high susceptibility to the exposure. No substantial differences were also found among the ac and dc corona treated samples as regards the mechanical properties. The XPS and FTIR analyses revealed proofs of surface oxidation for the samples treated by ac corona, while the samples treated by dc corona showed much less tendency for oxidation.
引用
收藏
页码:1984 / 1994
页数:11
相关论文
共 50 条
  • [1] Liquids Permeation into HTV Silicone Rubber under AC/DC Electric Field
    Bao Weining
    Liu Yingyan
    Gao Yanfeng
    Liang Xidong
    He Zilan
    Luo Bing
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 818 - 821
  • [2] Viability of Fillers in HTV Silicone Rubber in the AC and DC Inclined Plane Tests
    Ghunem, Refat Atef
    Ilhan, Suat
    Uckol, Halil Ibrahim
    Tuzun, Didem
    Hadjadj, Yazid
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (06) : 2144 - 2151
  • [3] Effect of DC Corona Aging on Properties of HTV Silicone Rubber and Alicyclic Epoxy Resin
    Huang X.
    Yang W.
    Tian Y.
    Yuan Z.
    Dianwang Jishu/Power System Technology, 2020, 44 (11): : 4454 - 4463
  • [4] The Influence of Corona Intensity on the TSC of HTV Silicone Rubber
    Ding, Lijian
    Liang, Ying
    Tu, Youping
    Wang, Wei
    Li, C. R.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 691 - +
  • [5] TSC of HTV Silicone Rubber during Corona Deterioration
    Liang, Ying
    Ding, Lijian
    Li, C. R.
    Tu, Youping
    Yang, Kun
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 114 - +
  • [6] Effect of mineral oil on flashover voltage of HTV silicone rubber under AC corona ageing: from the view of trap level distribution
    Yu, Yu
    Wang, Ke
    Yang, Yan
    Li, Gang
    Wu, Guangning
    Li, Jinzhong
    Gao, Bo
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (23) : 5498 - 5504
  • [7] A Study on the influence of Ozone on Aging of HTV Silicone Rubber
    Tu, Youping
    Wang, Wei
    Li, Min
    Ding, Lijian
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 694 - +
  • [8] Hydrophobicity Loss of HTV Silicone Rubber after Corona Discharge
    Liang, Ying
    Ding, Lijian
    Li, C. R.
    Tu, Youping
    Yang, Kun
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 122 - +
  • [9] Effect of Corona on the Hydrophobicity Recovery Characteristics of HTV Silicone Rubber
    Liang, Ying
    Ding, Lijian
    Li, C. R.
    Tu, Youping
    Yang, Kun
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 118 - +
  • [10] Effect of corona discharge on the hydrophobicity recovery of HTV silicone rubber
    Liang, Ying
    Li, Cheng-Rong
    Ding, Li-Jian
    Yang, Kun
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (01): : 30 - 32