Simulation and size optimization of a pumped-storage power plant for the recovery of wind-farms rejected energy

被引:123
作者
Anagnostopoulos, J. S. [1 ]
Papantonis, D. E. [1 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, Athens 15780, Greece
关键词
optimum sizing; pumped-storage plant; wind-hydro power generation; autonomous electric grids; energy storage; wind energy penetration;
D O I
10.1016/j.renene.2007.08.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The hybrid wind-hydro power generation appears to be an attractive solution for isolated, autonomous electric grids in order to increase the wind energy penetration and cost-effectiveness. This work presents a numerical methodology for optimum sizing of the various components of it reversible hydraulic system designed to recover the electric energy that is rejected from wind farms due to imposed grid limitations. The algorithm is applied to study it practical case using time variation data of rejected power from a number of wind farms installed in the island of Crete, Greece. The free design parameters of the system include the turbine size, the size and the number of the pumps, the penstock diameter and thickness, and the reservoirs' capacity, whereas some critical financial parameters are also considered. The numerical procedure combines an evaluation algorithm that simulates in detail the plant operation during a 12-month period, and an automated optimization software based on evolutionary algorithms. The economic analysis uses dynamic evaluation methods and the attainability of various objectives is examined using single or multi-objective optimizations. In addition, the developed numerical toot is used to perform several parametric studies and sensitivity tests in order to analyse in depth the influence of the most important parameters on the plant operation and economic behaviour. The results showed that a well optimized design may be crucial for the technical and economic viability of the examined system. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1685 / 1694
页数:10
相关论文
共 14 条
[1]  
ANCONA DF, 2003, EUR WIND EN C MADR S
[2]   Feasibility study of a hybrid wind/hydro power-system for low-cost electricity production [J].
Bakos, GC .
APPLIED ENERGY, 2002, 72 (3-4) :599-608
[3]   Optimal operation and hydro storage sizing of a wind-hydro power plant [J].
Castronuovo, ED ;
Lopes, JAP .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2004, 26 (10) :771-778
[4]  
CHRISTAKIS D, 1997, EUR C REN EN IMPL AT
[5]   Design of optimal aerodynamic shapes using stochastic optimization methods and computational intelligence [J].
Giannakoglou, KC .
PROGRESS IN AEROSPACE SCIENCES, 2002, 38 (01) :43-76
[6]  
*GREEK MIN DEV DEP, 2005, 3 NAT REP PEN LEV RE
[7]   Income loss due to wind energy rejected by the Crete island electrical network - the present situation [J].
Kaldellis, JK ;
Kavadias, KA ;
Filios, AE ;
Garofallakis, S .
APPLIED ENERGY, 2004, 79 (02) :127-144
[8]   Parametrical investigation of the wind-hydro electricity production solution for Aegean Archipelago [J].
Kaldellis, JK .
ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (16) :2097-2113
[9]   Evaluation of the wind-hydro energy solution for remote islands [J].
Kaldellis, JK ;
Kavadias, K ;
Christinakis, E .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (09) :1105-1120
[10]   A stand-alone photovoltaic power system for remote villages using pumped water energy storage [J].
Manolakos, D ;
Papadakis, G ;
Papantonis, D ;
Kyritsis, S .
ENERGY, 2004, 29 (01) :57-69