Flexible film dosimeter for in vivo dosimetry

被引:19
作者
Cho, Jin Dong [1 ,2 ,3 ]
Son, Jaeman [1 ,4 ]
Sung, Jiwon [1 ,4 ]
Choi, Chang Heon [1 ,2 ,4 ]
Kim, Jin Sung [3 ]
Wu, Hong-Gyun [1 ,2 ,4 ,5 ,6 ]
Park, Jong Min [1 ,2 ,4 ,7 ]
Kim, Jung-in [1 ,2 ,4 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 03080, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 03080, South Korea
[3] Yonsei Univ, Coll Med, Dept Radiat Oncol, Seoul 03722, South Korea
[4] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul 03080, South Korea
[6] Seoul Natl Univ, Coll Med, Canc Res Inst, Seoul 03080, South Korea
[7] Adv Inst Convergence Technol, Robot Res Lab Extreme Environm, Suwon 16229, South Korea
基金
新加坡国家研究基金会;
关键词
in vivo dosimetry; flexible dosimeter; radiochromic film; EBT3 RADIOCHROMIC FILMS; X-RAY-BEAMS; DOSE MEASUREMENTS; PHOTON; SENSITIVITY; BOLUS; TOXICITY; GREEN;
D O I
10.1002/mp.14162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aims of this study were to develop a flexible film dosimeter applicable to the irregular surface of a patient for in vivo dosimetry and to evaluate the device's dosimetric characteristics. Methods A flexible film dosimeter with active layers consisting of radiochromic-sensitive films and flexible silicone materials was constructed. The dose-response, sensitivity, scanning orientation dependence, energy dependence, and dose rate dependence of the flexible film dosimeter were tested. Irradiated dosimeters were scanned 24 h post-irradiation, and the region of interest was 5 mm x 5 mm. Biological stability tests ensured the safety of application of the flexible film dosimeter for patients. A preliminary clinical study with the flexible film dosimeter was implemented on four patients. Results The red channel demonstrated the highest sensitivity among all channels, and the response sensitivity of the dosimeter decreased with the applied dose, which were the same as the characteristics of GAFCHROMIC EBT3 radiochromic films. The flexible film dosimeter showed no significant energy dependence for photon beams of 6 MV, 6 MV flattening filter-free (FFF), 10 MV, and 15 MV. The flexible film dosimeter showed no substantial dose rate dependence with 6 or 6 MV FFF. In terms of biological stability, the flexible film dosimeter demonstrated no cytotoxicity, no irritation, and no skin sensitization. In the preliminary clinical study, the dose differences between the measurements with the flexible film dosimeter and calculations with the treatment planning system ranged from -0.1% to 1.2% for all patients. Conclusions The dosimeter developed in this study is a flexible film capable of attachment to a curved skin surface. The biological test results indicate the stability of the flexible film dosimeter. The preliminary clinical study showed that the flexible film dosimeter can be successfully applied as an in vivo dosimeter.
引用
收藏
页码:3204 / 3213
页数:10
相关论文
共 41 条
[1]   Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques [J].
Akino, Yuichi ;
Das, Indra J. ;
Bartlett, Gregory K. ;
Zhang, Hualin ;
Thompson, Elizabeth ;
Zook, Jennifer E. .
MEDICAL PHYSICS, 2013, 40 (01)
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]   A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT [J].
Andres, C. ;
del Castillo, A. ;
Tortosa, R. ;
Alonso, D. ;
Barquero, R. .
MEDICAL PHYSICS, 2010, 37 (12) :6271-6278
[4]   Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification [J].
Borca, Valeria Casanova ;
Pasquino, Massimo ;
Russo, Giuliana ;
Grosso, Pierangelo ;
Cante, Domenico ;
Sciacero, Piera ;
Girelli, Giuseppe ;
La Porta, Maria Rosa ;
Tofani, Santi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02) :158-171
[5]   Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams [J].
Brown, Thomas A. D. ;
Hogstrom, Kenneth R. ;
Alvarez, Diane ;
Matthews, Kenneth L., II ;
Ham, Kyungmin ;
Dugas, Joseph P. .
MEDICAL PHYSICS, 2012, 39 (12) :7412-7417
[6]   Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy [J].
Butson, MJ ;
Cheung, T ;
Yu, P ;
Metcalfe, P .
RADIATION MEASUREMENTS, 2000, 32 (03) :201-204
[7]   Multilayer Gafchromic film detectors for breast skin dose determination in vivo [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02) :N31-N37
[8]   Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: A radiochromic EBT film dosimetry study in phantom [J].
Chiu-Tsao, Sou-Tung ;
Chan, Maria F. .
MEDICAL PHYSICS, 2010, 37 (07) :3611-3620
[9]   Polyvinyl alcohol-Fricke hydrogel and cryogel:: two new gel dosimetry systems with low Fe3+ diffusion [J].
Chu, KC ;
Jordan, KJ ;
Battista, JJ ;
Van Dyk, J ;
Rutt, BK .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :955-969
[10]   An investigation of a novel reusable radiochromic sheet for 2D dose measurement [J].
Collins, Cielle ;
Yoon, Suk Whan ;
Kodra, Jacob ;
Coakley, Robert ;
Subashi, Ergys ;
Sidhu, Kulbir ;
Adamovics, John ;
Oldham, Mark .
MEDICAL PHYSICS, 2019, 46 (12) :5758-5769