Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging

被引:19
作者
Askew, J. Wells [1 ,4 ]
Miller, Todd D. [1 ]
Ruter, Royce L. [2 ]
Jordan, Lennon G. [2 ]
Hodge, David O. [3 ]
Gibbons, Raymond J. [1 ]
O'Connor, Michael K. [2 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Dept Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin, Div Nucl Med, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biostat, Dept Hlth Sci Res, Rochester, MN 55905 USA
[4] Mayo Clin, Coll Med, Rochester, MN 55905 USA
关键词
Myocardial perfusion imaging; solid-state cardiac camera; ultrafast cardiac camera; SPECT acquisition; EMISSION COMPUTED-TOMOGRAPHY; HIGH-SPEED;
D O I
10.1007/s12350-011-9423-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. A novel ultra-fast solid-state cardiac camera (Discovery NM 530c, General Electric) allows much shorter acquisition times compared to standard dual-detector SPECT cameras. This design enables investigation of the potential for early myocardial perfusion imaging (MPI) following a rest injection of technetium-99m (Tc-99m) rather than the conventional 45-60 minute delay in image acquisition. Methods. A total of 30 patients underwent MPI at rest using Tc-99m sestamibi (n = 9) or tetrofosmin (n = 21). A 12 minute image acquisition in list mode was performed immediately following isotope injection. Patients also underwent a conventional delayed image acquisition 60 minutes following the rest isotope injection (image acquisition over 4 minutes). The immediate 12 minute acquisition was divided into three 4-minute intervals for image reconstruction (0-4, 4-8, and 8-12 minutes). The perfusion images were interpreted by two experienced physicians who evaluated each study for overall image quality (good, acceptable, or unacceptable) and graded each image using the summed rest score (SRS) and the standard 17-segment, 5-point scale model. Results. The images acquired in the 0-8 minute time interval were predominantly uninterpretable due to excessive blood pool uptake. The images acquired in the 8-12 minute time interval were interpretable and compared to the conventional images obtained at 60 minutes. Overall image quality was better on the 60 minute image (17 good, 13 acceptable) compared with 8-12 minute image (3 good, 25 acceptable, 2 unacceptable). Sixteen of the 30 patients had an improvement in overall image quality by at least one category using the 60 minute delayed image. Nine of the 30 patients (2 Tc-99m sestamibi; 7 Tc-99m tetrofosmin) had at least one uninterpretable myocardial segment due to liver and/or bowel overlapping the myocardium on the 8-12 minute images vs 1 patient (1 myocardial segment) with this problem on the 60 minute delayed images (P = .005). Uninterpretable segments (total of 16) on the 8-12 minute images were confined to the apex and inferior wall. The mean SRS of the interpretable 8-12 minute images (n = 21) was 3.2 (95% confidence intervals; 1.0, 5.4) compared to 1.6 (95% confidence intervals; 0, 3.3) on the 60 minute delayed images in those patients (P = .005). Conclusions. Overall image quality was better with fewer uninterpretable studies and a lower SRS on the rest images obtained at 60 minutes compared to early image acquisition (8-12 minutes following isotope injection). These findings do not support the routine use of early image acquisition with this new solid-state ultra-fast camera system. (J Nucl Cardiol 2011;18:840-6.)
引用
收藏
页码:840 / 846
页数:7
相关论文
共 14 条
[1]   Stress Thallium-201/Rest Technetium-99m Sequential Dual Isotope High-Speed Myocardial Perfusion Imaging [J].
Berman, Daniel S. ;
Kang, Xingping ;
Tamarappoo, Balaji ;
Wolak, Arik ;
Hayes, Sean W. ;
Nakazato, Ryo ;
Thomson, Louise E. J. ;
Kite, Faith ;
Cohen, Ishac ;
Slomka, Piotr J. ;
Einstein, Andrew J. ;
Friedman, John D. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) :273-282
[2]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[3]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[4]   Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera [J].
Duvall, W. Lane ;
Croft, Lori B. ;
Godiwala, Tapan ;
Ginsberg, Eric ;
George, Titus ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) :1009-1014
[5]   Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras [J].
Esteves, Fabio P. ;
Raggi, Paolo ;
Folks, Russell D. ;
Keidar, Zohar ;
Askew, J. Wells ;
Rispler, Shmuel ;
O'Connor, Michael K. ;
Verdes, Liudmilla ;
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) :927-934
[6]   Comparison Between Ultrafast and Standard Single-Photon Emission CT in Patients With Coronary Artery Disease A Pilot Study [J].
Gimelli, Alessia ;
Bottai, Matteo ;
Giorgetti, Assuero ;
Genovesi, Dario ;
Kusch, Annette ;
Ripoli, Andrea ;
Marzullo, Paolo .
CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (01) :51-58
[7]  
Henzlova MJ, 2009, ASNC IMAGING GUIDELI
[8]   Nuclear Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride Detector Technique: Optimized Protocol for Scan Time Reduction [J].
Herzog, Bernhard A. ;
Buechel, Ronny R. ;
Katz, Ruth ;
Brueckner, Michael ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Valenta, Ines ;
Gaemperli, Oliver ;
Treyer, Valerie ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (01) :46-51
[9]   Single photon-emission computed tomography [J].
Holly, Thomas A. ;
Abbott, Brian G. ;
Al-Mallah, Mouaz ;
Calnon, Dennis A. ;
Cohen, Mylan C. ;
DiFilippo, Frank P. ;
Ficaro, Edward P. ;
Freeman, Michael R. ;
Hendel, Robert C. ;
Jain, Diwakar ;
Leonard, Scott M. ;
Nichols, Kenneth J. ;
Polk, Donna M. ;
Soman, Prem .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (05) :941-973
[10]   Quantitative Upright-Supine High-Speed SPECT Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: Correlation with Invasive Coronary Angiography [J].
Nakazato, Ryo ;
Tamarappoo, Balaji K. ;
Kang, Xingping ;
Wolak, Arik ;
Kite, Faith ;
Hayes, Sean W. ;
Thomson, Louise E. J. ;
Friedman, John D. ;
Berman, Daniel S. ;
Slomka, Piotr J. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (11) :1724-1731