Investigation of a real-time EPID-based patient dose monitoring safety system using site-specific control limits

被引:33
作者
Fuangrod, Todsaporn [1 ]
Greer, Peter B. [2 ,4 ]
Woodruff, Henry C. [3 ]
Simpson, John [2 ,4 ]
Bhatia, Shashank [4 ]
Zwan, Benjamin [2 ,5 ]
vanBeek, Timothy A. [6 ,7 ,8 ]
McCurdy, Boyd M. C. [6 ,7 ,8 ]
Middleton, Richard H. [1 ]
机构
[1] Univ Newcastle, Sch Elect Engn & Comp Sci, Fac Engn & Built Environm, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Math & Phys Sci, Fac Sci & IT, Newcastle, NSW, Australia
[3] Univ Sydney, Sydney Med Sch, Radiat Phys Lab, Sydney, NSW, Australia
[4] Calvary Mater Newcastle Hosp, Newcastle, NSW, Australia
[5] Cent Coast Canc Ctr, Gosford, NSW, Australia
[6] CancerCare Manitoba, Div Med Phys, Winnipeg, MB, Canada
[7] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB, Canada
[8] Univ Manitoba, Dept Radiol, Winnipeg, MB, Canada
来源
RADIATION ONCOLOGY | 2016年 / 11卷
关键词
Statistical process control; Real-time patient dose monitoring safety system; EPID; STATISTICAL PROCESS-CONTROL; VERIFICATION; DOSIMETRY; IMRT; DELIVERY; ERROR;
D O I
10.1186/s13014-016-0682-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study is to investigate the performance and limitations of a real-time transit electronic portal imaging device (EPID) dosimetry system for error detection during dynamic intensity modulated radiation therapy (IMRT) treatment delivery. Sites studied are prostate, head and neck (HN), and rectal cancer treatments. Methods: The system compares measured cumulative transit EPID image frames with predicted cumulative image frames in real-time during treatment using a chi comparison with 4 %, 4 mm criteria. The treatment site-specific thresholds (prostate, HN and rectum IMRT) were determined using initial data collected from 137 patients (274 measured treatment fractions) and a statistical process control methodology. These thresholds were then applied to data from 15 selected patients including 5 prostate, 5 HN, and 5 rectum IMRT treatments for system evaluation and classification of error sources. Results: Clinical demonstration of real-time transit EPID dosimetry in IMRT was presented. For error simulation, the system could detect gross errors (i.e. wrong patient, wrong plan, wrong gantry angle) immediately after EPID stabilisation; 2 seconds after the start of treatment. The average rate of error detection was 7.0 % (prostate = 5.6 %, HN= 8.7 % and rectum = 6.7 %). The detected errors were classified as either clinical in origin (e.g. patient anatomical changes), or non-clinical in origin (e.g. detection system errors). Classified errors were 3.2 % clinical and 3.9 % non-clinical. Conclusion: An EPID-based real-time error detection method for treatment verification during dynamic IMRT has been developed and tested for its performance and limitations. The system is able to detect gross errors in real-time, however improvement in system robustness is required to reduce the non-clinical sources of error detection.
引用
收藏
页数:10
相关论文
共 27 条
  • [1] A revision of the γ-evaluation concept for the comparison of dose distributions
    Bakai, A
    Alber, M
    Nüsslin, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (21) : 3543 - 3553
  • [2] A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy
    Bojechko, Casey
    Phillps, Mark
    Kalet, Alan
    Ford, Eric C.
    [J]. MEDICAL PHYSICS, 2015, 42 (09) : 5363 - 5369
  • [3] Comprehensive fluence model for absolute portal dose image prediction
    Chytyk, K.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1389 - 1398
  • [4] Model-based prediction of portal dose images during patient treatment
    Chytyk-Praznik, K.
    VanUytven, E.
    vanBeek, T. A.
    Greer, P. B.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [5] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [6] An independent system for real-time dynamic multileaf collimation trajectory verification using EPID
    Fuangrod, Todsaporn
    Woodruff, Henry C.
    Rowshanfarzad, Pejman
    O'Connor, Daryl J.
    Middleton, Richard H.
    Greer, Peter B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01) : 61 - 81
  • [7] A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment
    Fuangrod, Todsaporn
    Woodruff, Henry C.
    van Uytven, Eric
    McCurdy, Boyd M. C.
    Kuncic, Zdenka
    O'Connor, Daryl J.
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [8] A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)
    Gerard, Karine
    Grandhaye, Jean-Pierre
    Marchesi, Vincent
    Kafrouni, Hanna
    Husson, Francois
    Aletti, Pierre
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1275 - 1285
  • [9] Error in the delivery of radiation therapy: Results of a quality assurance review
    Huang, G
    Medlam, G
    Lee, J
    Billingsley, S
    Bissonnette, JP
    Ringash, J
    Kane, G
    Hodgson, DC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1590 - 1595
  • [10] Evaluation of the gamma dose distribution comparison method
    Low, DA
    Dempsey, JF
    [J]. MEDICAL PHYSICS, 2003, 30 (09) : 2455 - 2464