Prediction of fluoroscopic angulation and coronary sinus location by CT in the context of transcatheter mitral valve implantation

被引:38
作者
Blanke, Philipp [1 ]
Dvir, Danny [1 ]
Naoum, Christopher [1 ]
Cheung, Anson [1 ]
Ye, Jian [1 ]
Theriault-Lauzier, Pascal [2 ]
Spaziano, Marco [2 ]
Boone, Robert H. [1 ]
Wood, David A. [1 ]
Piazza, Nicola [2 ]
Webb, John G. [1 ]
Leipsic, Jonathon [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Ctr Heart Valve Innovat, Vancouver, BC V6Z 1Y6, Canada
[2] McGill Univ, Dept Med, Ctr Hlth, Div Cardiol, Montreal, PQ, Canada
关键词
Mitral regurgitation; Mitral annulus; TMVI; Transcatheter mitral valve implantation; Transapical mitral valve replacement; Computed tomography; MULTISLICE COMPUTED-TOMOGRAPHY; ANNULUS; ANNULOPLASTY; INSIGHT; ANATOMY;
D O I
10.1016/j.jcct.2015.02.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to determine if preprocedural CT can predict appropriate fluoroscopic angulations to achieve a coplanar view during transcatheter mitral valve implantation (TMVI) and to assess the relationship of the mitral annulus and the coronary sinus to determine the feasibility of using this as an additional landmark on fluoroscopy. Methods: With CT, the mitial annulus was segmented in 25 patients with functional mitral regurgitation. After this, optimal projection curves were plotted and the necessary angulations for specific views parallel to the trigone-to-trigone line (TT view) and septal-to-lateral distance (SL view) were noted. The outer contour of the coronary sinus and great cardiac vein were segmented to simulate a guide wire, and its relation to the annular plane was assessed. Employed angulations and coplanarity of device depiction were investigated in 4 patients who underwent TMVI. Results: The mitral annulus is oriented in an anterior superior fashion with tilting to the right. SL and TT views were found at 29.4 +/- 9.0 degrees right anterior oblique (RAO), 20.1 +/- 8.7 degrees cranial (CAU) and 81.6 +/- 18.9 degrees RAO, 56.7 +/- 8.0 degrees caudal (CAU). The optimal projection curve and the relationship of coronary sinus to the mitral annular plane showed a wide intersubject variability. Commonly, the coronary sinus passed along the atrial wall with a mean distance of 13.2 +/- 3.7 mm toward the mitral annular plane at P2 and 1.4 +/- 3.1 mm anteriorly in alignment with the TT line. Coplanar depiction of the TMVI prosthesis was achieved in all 4 patients, with a compromise view chosen on the optimal projection curve between the TT view and SL view. Conclusion: CT allows for prediction of optimal fluoroscopic angulations to achieve a coplanar view of the mitral annulus. The relationship of the coronary sinus to the mitral annulus is variable and preprocedural CT segmentation may allow for a more patientspecific approach to the use of a coronary sinus guide wire as a fluoroscopic landmark. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 13 条
[1]   Tiara: A Novel Catheter-Based Mitral Valve Bioprosthesis Initial Experiments and Short-Term Pre-Clinical Results [J].
Banai, Shmuel ;
Jolicoeur, E. Marc ;
Schwartz, Marc ;
Garceau, Patrick ;
Biner, Simon ;
Tanguay, Jean-Francois ;
Cartier, Raymond ;
Verheye, Stefan ;
White, Christopher J. ;
Edelman, Elazer .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (15) :1430-1431
[2]  
Bapat Vinayak, 2014, EuroIntervention, V10 Suppl U, pU120, DOI 10.4244/EIJV10SUA18
[3]  
Blanke P, 2015, JACC IMG IN PRESS
[4]   A simplified D-shaped model of the mitral annulus to facilitate CT-based sizing before transcatheter mitral valve implantation [J].
Blanke, Philipp ;
Dvir, Danny ;
Cheung, Anson ;
Ye, Jian ;
Levine, Robert A. ;
Precious, Bruce ;
Berger, Adam ;
Stub, Dion ;
Hague, Cameron ;
Murphy, Darra ;
Thompson, Christopher ;
Munt, Brad ;
Moss, Robert ;
Boone, Robert ;
Wood, David ;
Pache, Gregor ;
Webb, John ;
Leipsic, Jonathon .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (06) :459-467
[5]   Short-Term Results of Transapical Transcatheter Mitral Valve Implantation for Mitral Regurgitation [J].
Cheung, Anson ;
Webb, John ;
Verheye, Stefan ;
Moss, Robert ;
Boone, Robert ;
Leipsic, Jonathan ;
Ree, Ron ;
Banai, Shmuel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (17) :1814-1819
[6]  
Cheung Anson, 2014, EuroIntervention, V10 Suppl U, pU115, DOI 10.4244/EIJV10SUA17
[7]   Insight Into the Dynamics of the Coronary Sinus/Great Cardiac Vein and the Mitral Annulus Implications for Percutaneous Mitral Annuloplasty Techniques [J].
del Valle-Fernandez, Raquel ;
Jelnin, Vladimir ;
Panagopoulos, Georgia ;
Ruiz, Carlos E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (06) :557-564
[8]   Multislice Computed Tomography for Prediction of Optimal Angiographic Deployment Projections During Transcatheter Aortic Valve Implantation [J].
Gurvitch, Ronen ;
Wood, David A. ;
Leipsic, Jonathon ;
Tay, Edgar ;
Johnson, Mark ;
Ye, Jian ;
Nietlispach, Fabian ;
Wijesinghe, Namal ;
Cheung, Anson ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1157-1165
[9]   Three-dimensional measurement of the mitral annulus by multiplane transesophageal echocardiography: In vitro validation and in vivo demonstration [J].
Legget, ME ;
Bashein, G ;
McDonald, JA ;
Munt, BI ;
Martin, RW ;
Otto, CM ;
Sheehan, FH .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (02) :188-200
[10]   3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE MITRAL-VALVE, WITH IMPLICATIONS FOR THE DIAGNOSIS OF MITRAL-VALVE PROLAPSE [J].
LEVINE, RA ;
HANDSCHUMACHER, MD ;
SANFILIPPO, AJ ;
HAGEGE, AA ;
HARRIGAN, P ;
MARSHALL, JE ;
WEYMAN, AE .
CIRCULATION, 1989, 80 (03) :589-598