Diagnostic value of 3D time-of-flight MRA in trigeminal neuralgia

被引:13
作者
Cai, Jing [2 ]
Xin, Zhen-Xue [3 ]
Zhang, Yu-Qiang [4 ]
Sun, Jie [5 ]
Lu, Ji-Liang [6 ]
Xie, Feng [1 ]
机构
[1] LanLing Peoples Hosp, Dept Neurosurg, Lanling 277700, Peoples R China
[2] LinYi Peoples Hosp, Dept Neurosurg, Linyi, Peoples R China
[3] Second Peoples Hosp Liaocheng City, Dept Neurosurg, Liaocheng, Peoples R China
[4] Linzi Dist Peoples Hosp Zibo City, Dept Neurosurg, Zibo, Peoples R China
[5] Penglai Tradit Chinese Med Hosp, Dept Neurosurg, Penglai, Peoples R China
[6] Yiyuan Peoples Hosp, Dept Radiol, Yiyuan, Peoples R China
关键词
3D time-of-flight MRA; Diagnostic value; Neuroimaging technique; Neurovascular compression; Trigeminal neuralgia; MAGNETIC-RESONANCE ANGIOGRAPHY; CHARACTERISTIC ROC CURVE; NEUROVASCULAR COMPRESSION; MICROVASCULAR DECOMPRESSION; SURGICAL FINDINGS; CONSECUTIVE PATIENTS; 3.0; T; RADIOSURGERY; INTENSITY; SIGNAL;
D O I
10.1016/j.jocn.2015.02.023
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The aim of this meta-analysis was to evaluate the diagnostic value of 3D time-of-flight magnetic resonance angiography (3D-TOF-MRA) in trigeminal neuralgia (TN). Relevant studies were identified by computerized database searches supplemented by manual search strategies. The studies were included in accordance with stringent inclusion and exclusion criteria. Following a multistep screening process, high quality studies related to the diagnostic value of 3D-TOF-MRA in TN were selected for meta-analysis. Statistical analyses were conducted using Statistical Analysis Software (version 8.2; SAS Institute, Cary, NC, USA) and Meta Disc (version 1.4; Unit of Clinical Biostatistics, Ramon y Cajal Hospital, Madrid, Spain). For the present meta-analysis, we initially retrieved 95 studies from database searches. A total of 13 studies were eventually enrolled containing a combined total of 1084 TN patients. The meta-analysis results demonstrated that the sensitivity and specificity of the diagnostic value of 3D-TOF-MRA in TN were 95% (95% confidence interval [CI] 0.93-0.96) and 77% (95% CI 0.66-0.86), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 2.72 (95% CI 1.81-4.09) and 0.08 (95% CI 0.06-0.12), respectively. The pooled diagnostic odds ratio of 3D-TOF-MRA in TN was 52.92 (95% CI 26.39-106.11), and the corresponding area under the curve in the summary receiver operating characteristic curve based on the 3D-TOF-MRA diagnostic image of observers was 0.9695 (standard error 0.0165). Our results suggest that 3D-TOF-MRA has excellent sensitivity and specificity as a diagnostic tool for TN, and that it can accurately identify neurovascular compression in TN patients. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1343 / 1348
页数:6
相关论文
共 41 条
[1]   High-resolution three-dimensional magnetic resonance angiography and three-dimensional spoiled gradient-recalled imaging in the evaluation of neurovascular compression in patients with trigeminal neuralgia: A double-blind pilot study [J].
Anderson, VC ;
Berryhill, PC ;
Sandquist, MA ;
Ciaverella, DP ;
Nesbit, GM ;
Burchiel, KJ .
NEUROSURGERY, 2006, 58 (04) :666-671
[2]   Sensitivity and specificity of MRA in the diagnosis of neurovascular compression in patients with trigeminal neuralgia - A correlation of MRA and surgical findings [J].
Boecher-Schwarz, HG ;
Bruehl, K ;
Kessel, G ;
Guenthner, M ;
Perneczky, A ;
Stoeter, P .
NEURORADIOLOGY, 1998, 40 (02) :88-95
[3]   The Predictive Value of 3D Time-of-Flight MR Angiography in Assessment of Brain Arteriovenous Malformation Obliteration after Radiosurgery [J].
Buis, D. R. ;
Bot, J. C. J. ;
Barkhof, F. ;
Knol, D. L. ;
Lagerwaard, F. J. ;
Slotman, B. J. ;
Vandertop, W. P. ;
van den Berg, R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (02) :232-238
[4]   Microvascular decompression in trigeminal neuralgia: A correlation of three-dimensional time-of-flight magnetic resonance angiography and surgical findings [J].
Chang, JW ;
Chang, JH ;
Park, YG ;
Chung, SS .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2000, 74 (3-4) :167-174
[5]   The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed [J].
Deeks, JJ ;
Macaskill, P ;
Irwig, L .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) :882-893
[6]  
Dhople AA, 2009, J NEUROSURG, V111, P351, DOI 10.3171/2009.2.JNS08977
[7]   High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T [J].
Garcia, M. ;
Naraghi, R. ;
Zumbrunn, T. ;
Roesch, J. ;
Hastreiter, P. ;
Doerfler, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) :1251-1256
[8]   Practice Parameter: The diagnostic evaluation and treatment of trigeminal neuralgia (an evidence-based review) - Report of the quality standards subcommittee of the American academy of and the European federation of neurological societies [J].
Gronseth, G. ;
Cruccu, G. ;
Alksne, J. ;
Argoff, C. ;
Brainin, M. ;
Burchiel, K. ;
Nurmikko, T. ;
Zakrzewska, J. M. .
NEUROLOGY, 2008, 71 (15) :1183-1190
[9]   Cranial nerve vascular compression syndromes of the trigeminal, facial and vago-glossopharyngeal nerves: comparative anatomical study of the central myelin portion and transitional zone; correlations with incidences of corresponding hyperactive dysfunctional syndromes [J].
Guclu, Bulent ;
Sindou, Marc ;
Meyronet, David ;
Streichenberger, Nathalie ;
Simon, Emile ;
Mertens, Patrick .
ACTA NEUROCHIRURGICA, 2011, 153 (12) :2365-2375
[10]   Intraplaque High-Intensity Signal on 3D Time-of-Flight MR Angiography Is Strongly Associated with Symptomatic Carotid Artery Stenosis [J].
Gupta, A. ;
Baradaran, H. ;
Kamel, H. ;
Mangla, A. ;
Pandya, A. ;
Fodera, V. ;
Dunning, A. ;
Sanelli, P. C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (03) :557-561