Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography-mass spectrometry vs. liquid chromatography-trapped-ion-mobility-mass spectrometry

被引:42
作者
Baglai, Anna [1 ,2 ]
Gargano, Andrea F. G. [1 ,2 ]
Jordens, Jan [3 ]
Mengerink, Ynze [3 ]
Honing, Maarten [3 ,4 ]
van der Wal, Sjoerd [2 ]
Schoenmakers, Peter J. [2 ]
机构
[1] TI COAST, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[2] Univ Amsterdam, Vant Hoff Inst Mol Sci, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[3] DSM Resolve, Urmonderbaan 22, NL-6167 RD Geleen, Netherlands
[4] Vrije Univ, Div BioAnalyt Chem, De Boelelaan 1083, NL-1081 HV Amsterdam, Netherlands
关键词
Lipidomics; Multidimensional separation; Trapped-ion-mobility mass spectrometry; On-line comprehensive two-dimensional; liquid chromatography; Human plasma; Untargeted analysis; COLLISION CROSS-SECTION; STRATUM-CORNEUM LIPIDS; PEAK-CAPACITY; ELECTROSPRAY-IONIZATION; STRUCTURAL-CHARACTERIZATION; BIOLOGICAL-SYSTEMS; FT-ICR; PERFORMANCE; PHOSPHOLIPIDS; TIME;
D O I
10.1016/j.chroma.2017.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC x LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped ion -mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC x LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 103
页数:14
相关论文
共 95 条
[1]   Isomer separation of polybrominated diphenyl ether metabolites using nanoESI-TIMS-MS [J].
Adams, Kendra J. ;
Montero, Dennise ;
Aga, Diana ;
Fernandez-Lima, Francisco .
INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2016, 19 (2-3) :69-76
[2]   Three-dimensional enhanced lipidomics analysis combining UPLC, differential ion mobility spectrometry, and mass spectrometric separation strategies [J].
Baker, Paul R. S. ;
Armando, Aaron M. ;
Campbell, J. Larry ;
Quehenberger, Oswald ;
Dennis, Edward A. .
JOURNAL OF LIPID RESEARCH, 2014, 55 (11) :2432-2442
[3]   Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces [J].
Beccaria, Marco ;
Inferrera, Veronica ;
Rigano, Francesca ;
Gorynski, Krzysztof ;
Purcaro, Giorgia ;
Pawliszyn, Janusz ;
Dugo, Paola ;
Mondello, Luigi .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1509 :69-82
[4]  
Benigni P., 2016, INT J ION MOBILITY S, V1, P10
[5]   Oversampling Selective Accumulation Trapped Ion Mobility Spectrometry Coupled to FT-ICR MS: Fundamentals and Applications [J].
Benigni, Paolo ;
Fernandez-Lima, Francisco .
ANALYTICAL CHEMISTRY, 2016, 88 (14) :7404-7412
[6]   Towards unsupervised polyaromatic hydrocarbons structural assignment from SA-TIMS - FTMS data [J].
Benigni, Paolo ;
Marin, Rebecca ;
Fernandez-Lima, Francisco .
INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2015, 18 (3-4) :151-157
[7]   Targeted High-Resolution Ion Mobility Separation Coupled to Ultrahigh-Resolution Mass Spectrometry of Endocrine Disruptors in Complex Mixtures [J].
Benigni, Paolo ;
Thompson, Christopher J. ;
Ridgeway, Mark E. ;
Park, Melvin A. ;
Fernandez-Lima, Francisco .
ANALYTICAL CHEMISTRY, 2015, 87 (08) :4321-4325
[8]   Development and validation of a sensitive and selective UHPLC-MS/MS method for simultaneous determination of both free and total eicosapentaeonic acid and docosahexenoic acid in human plasma [J].
Bowen, Chester L. ;
Kehler, Jonathan ;
Evans, Christopher A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30) :3125-3133
[9]   Liquid chromatographic-mass spectrometric analysis of phospholipids. Chromatography, ionization and quantification [J].
Brouwers, Jos F. .
BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (11) :763-775
[10]   Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry [J].
Byeon, Seul Kee ;
Lee, Ju Yong ;
Moon, Myeong Hee .
ANALYST, 2012, 137 (02) :451-458