Estimation of Blood Glucose Level of Type-2 Diabetes Patients Using Smartphone Video through PCA-DA

被引:10
作者
Chowdhury, Tauseef Tasin [1 ]
Mishma, Tahmin [1 ]
Osman, Saeem [1 ]
Rahman, Tanzilur [1 ]
机构
[1] North South Univ, ECE Dept, Dhaka, Bangladesh
来源
2019 6TH INTERNATIONAL CONFERENCE ON NETWORKING, SYSTEMS AND SECURITY (NSYSS 2019) | 2019年
关键词
Photoplethysmography; PPG; Blood Glucose; Signal Processing; PCR;
D O I
10.1145/3362966.3362983
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work proposes a smart phone video based approach for the estimation of blood glucose in a non-invasive way. Videos using smartphone camera are collected from the tip of the subject's finger and the frames are subsequently converted into Photoplethysmography (PPG) waveform. Gaussian filter along with Asymmetric Least Square methods have been applied on the PPG signals to remove the high frequency noise, optical and motion interferences. Different signal features such as Systolic and Diastolic Peaks, the time difference between consecutive peaks (DelT), and First Derivative peaks have been extracted from the processed signal. Finally, Principal Component Regression (PCR) has been applied for the prediction of glucose level from the extracted features. The proposed model while applied to an unbiased dataset could predict the glucose level with a Standard Error of Prediction (SEP) of 18.31 mg/dL.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 17 条
[1]  
Al-Mbaideen Amneh A., 2010, P IEEE SIGN PROC WOR
[2]   Photoplethysmography as a single source for analysis of sleep-disordered breathing in patients with severe cardiovascular disease [J].
Amir, Offer ;
Barak-Shinar, Deganit ;
Henry, Antonietta ;
Smart, Frank W. .
JOURNAL OF SLEEP RESEARCH, 2012, 21 (01) :94-100
[3]  
[Anonymous], 2010, VIVO GLUCOSE SENSING
[4]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[5]  
Banerjee R., 2018, P IEEE INT C AC SPEE
[6]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[7]   PATHOGENESIS OF NIDDM - A BALANCED OVERVIEW [J].
DEFRONZO, RA ;
BONADONNA, RC ;
FERRANNINI, E .
DIABETES CARE, 1992, 15 (03) :318-368
[8]  
Demirezen H., 2018, P 2018 IEEE INT C AC
[9]  
Eilers P.H., 2005, BASELINE CORRECTION, V1, P5, DOI DOI 10.1021/AC034173T
[10]  
Jonathan E, 2010, PHYSL MEASUREMENT, V31