Development and Application of Stir Bar Sorptive Extraction with Polyurethane Foams for the Determination of Testosterone and Methenolone in Urine Matrices

被引:14
作者
Sequeiros, R. C. P.
Neng, N. R.
Portugal, F. C. M.
Pinto, M. L.
Pires, J.
Nogueira, J. M. F. [1 ]
机构
[1] Univ Lisbon, Fac Sci Chem & Biochem, Dept Chem & Biochem, P-1749016 Lisbon, Portugal
关键词
MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; ANABOLIC-STEROIDS; TRACE ANALYSIS; WATER; OPTIMIZATION; SAMPLES; CONFIRMATION; SBSE;
D O I
10.1093/chrsci/49.4.297
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work describes the development, validation, and application of a novel methodology for the determination of testosterone and methenolone in urine matrices by stir bar sorptive extraction using polyurethane foams [SBSE(PU)] followed by liquid desorption and high-performance liquid chromatography with diode array detection. The methodology was optimized in terms of extraction time, agitation speed, pH, ionic strength and organic modifier, as well as back-extraction solvent and desorption time. Under optimized experimental conditions, convenient accuracy were achieved with average recoveries of 49.7 ± 8.6% for testosterone and 54.2 ± 4.7% for methenolone. Additionally, the methodology showed good precision (< 9%), excellent linear dynamic ranges (> 0.9963) and convenient detection limits (0.2-0.3 μg/L). When comparing the efficiency obtained by SBSE(PU) and with the conventional polydimethylsiloxane phase [SBSE(PDMS)], yields up to four-fold higher are attained for the former, under the same experimental conditions. The application of the proposed methodology for the analysis of testosterone and methenolone in urine matrices showed negligible matrix effects and good analytical performance.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 35 条
[1]  
ADRIANA S, 2007, J SEP SCI, V30, P257
[2]   Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection [J].
Almeida, C. ;
Nogueira, J. M. F. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) :1303-1311
[3]   Testing for natural and synthetic anabolic agents in human urine [J].
Ayotte, C ;
Goudreault, D ;
Charlebois, A .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :3-25
[4]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[5]  
2-4
[6]   Dual-phase twisters: A new approach to headspace sorptive extraction and stir bar sorptive extraction [J].
Bicchi, C ;
Cordero, C ;
Liberto, E ;
Rubiolo, P ;
Sgorbini, B ;
David, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1094 (1-2) :9-16
[7]   Excretion study of stanozolol in bovine by HPLC-tandem mass spectrometry [J].
Buiarelli, F ;
Cartoni, G ;
Coccioli, F ;
Merolle, M ;
Neri, B .
CHROMATOGRAPHIA, 2004, 60 (9-10) :545-551
[8]  
DAVID F, 2003, LC GC EUROPEA JUL, P1
[9]   Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry [J].
Deventer, K. ;
Van Eenoo, P. ;
Delbeke, F. T. .
BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (05) :429-433
[10]   Combining stir bar sorptive extraction and MEKC for the determination of polynuclear aromatic hydrocarbons in environmental and biological matrices [J].
do Rosario, Pedro M. A. ;
Nogueira, Jose M. F. .
ELECTROPHORESIS, 2006, 27 (23) :4694-4702