Randomised controlled trial of auto-adjusting positive airway pressure in morbidly obese patients requiring high therapeutic pressure delivery

被引:6
|
作者
Bakker, Jessie [1 ]
Campbell, Angela [1 ]
Neill, Alister [1 ]
机构
[1] Univ Otago, Dept Med, WellSleep Sleep Invest Ctr, Wellington 6242, New Zealand
关键词
auto-adjusting positive airway pressure; continuous positive airway pressure; obstructive sleep apnoea; randomised controlled trial; OBSTRUCTIVE SLEEP-APNEA; DAYTIME SLEEPINESS; BLOOD-PRESSURE; CONSTANT;
D O I
10.1111/j.1365-2869.2010.00846.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Auto-adjusting positive airway pressure (APAP) devices are being increasingly used to treat obstructive sleep apnoea (OSA). Anecdotal encounters of obese patients requiring high therapeutic pressure whose OSA was inadequately controlled by APAP led to this study aiming to compare the effectiveness of continuous positive airway pressure (CPAP) and APAP (S8 Autoset II (R), ResMed, NSW, Australia) in a randomised, single-blinded crossover trial. Twelve morbidly obese patients with severe OSA [mean +/- SD apnoea-hypopnoea index (AHI) 75.8 +/- 32.7, body mass index 49.9 +/- 5.2 kg m(-2), mean pressure 16.4 cmH(2)O] were consecutively recruited, and received CPAP or APAP in random order for six nights at home, separated by a four-night washout. Polysomnographic (PSG) indices of OSA were recorded at baseline and following each treatment arm. Both therapies substantially reduced the AHI (APAP 9.8 +/- 9.5 and CPAP 7.3 +/- 6.6 events h(-1); P = 0.35), but residual PSG measures of disease (AHI > 5) were common. APAP delivered a significantly lower 95th percentile pressure averaged over the home-use arm than CPAP (14.2 +/- 2.7 and 16.1 +/- 1.8 cmH(2)O, respectively, P = 0.02). The machine-scored AHI significantly overestimated the level of residual disease compared with the laboratory-scored AHI (using Chicago criteria); however, when the machine-scored AHI was <= 5 and <= 10 this was always confirmed by the PSG data. In morbidly obese OSA patients without significant co-morbid disease requiring high therapeutic pressure, our data provide support for the use of either APAP or manually titrated CPAP. We recommend objective assessment by sleep study if the S8 Autoset II indicates a high level of residual disease.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 50 条
  • [21] Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study
    Ricardo L. M. Duarte
    Bruno A. Mendes
    Tiago S. Oliveira-e-Sá
    Flavio J. Magalhães-da-Silveira
    David Gozal
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 3507 - 3512
  • [22] IMPROVEMENTS IN QUALITY OF LIFE IN FEMALE OBSTRUCTIVE SLEEP APNEA PATIENTS USING A GENDER SPECIFIC AUTO-ADJUSTING POSITIVE AIRWAY PRESSURE DEVICE
    Wimms, Alison
    Benjafield, Adam
    Martins, Dagmar
    Willes, Leslee
    Lips, Aline
    Fietze, Ingo
    Topfer, Volker
    Woehrle, Holger
    SLEEP, 2019, 42
  • [23] Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study
    Duarte, Ricardo L. M.
    Mendes, Bruno A.
    Oliveira-e-Sa, Tiago S.
    Magalhaes-da-Silveira, Flavio J.
    Gozal, David
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (12) : 3507 - 3512
  • [24] Fixed-pressure CPAP versus auto-adjusting CPAP: comparison of efficacy on blood pressure in obstructive sleep apnoea, a randomised clinical trial
    Pepin, J. L.
    Tamisier, R.
    Baguet, J. P.
    Lepaulle, B.
    Arbib, F.
    Arnol, N.
    Timsit, J. F.
    Levy, P.
    THORAX, 2016, 71 (08) : 726 - 733
  • [25] NightBalance Sleep Position Treatment Device Versus Auto-Adjusting Positive Airway Pressure for Treatment of Positional Obstructive Sleep Apnea
    Berry, Richard B.
    Uhles, Matthew L.
    Abaluck, Brian K.
    Winslow, David H.
    Schweitzer, Paula K.
    Gaskins, Raymond A., Jr.
    Doekel, Robert C., Jr.
    Emsellem, Helene A.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2019, 15 (07): : 947 - 956
  • [26] Formulas to predict continuous positive airway pressure level using a home auto-adjusting device for obstructive sleep apnea treatment
    Borsini, Eduardo
    Blanco, Magali
    Nigro, Carlos Alberto
    SLEEP AND BREATHING, 2024, 28 (05) : 2071 - 2079
  • [27] Positive airway pressure to treat co-morbid insomnia and sleep-disordered breathing: A rationale for advanced auto-adjusting dual pressure technology
    Krakow, B.
    McIver, N.
    Ulibarri, V.
    JOURNAL OF SLEEP RESEARCH, 2016, 25 : 44 - 44
  • [28] Auto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea
    Nolan, Geraldine M.
    Doherty, Liam S.
    Mc Nicholas, Walter T.
    SLEEP, 2007, 30 (02) : 189 - 194
  • [29] There is no difference in the adherence of continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome among the auto-adjusting CPAP machines
    Yaegashi, H.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 343 - 344
  • [30] A new characterization of adherence patterns to auto-adjusting positive airway pressure in severe obstructive sleep apnea syndrome: clinical and psychological determinants
    Rute Sampaio
    M. Graça Pereira
    João C. Winck
    Sleep and Breathing, 2013, 17 : 1145 - 1158