Randomised controlled trial of auto-adjusting positive airway pressure in morbidly obese patients requiring high therapeutic pressure delivery

被引:7
作者
Bakker, Jessie [1 ]
Campbell, Angela [1 ]
Neill, Alister [1 ]
机构
[1] Univ Otago, Dept Med, WellSleep Sleep Invest Ctr, Wellington 6242, New Zealand
关键词
auto-adjusting positive airway pressure; continuous positive airway pressure; obstructive sleep apnoea; randomised controlled trial; OBSTRUCTIVE SLEEP-APNEA; DAYTIME SLEEPINESS; BLOOD-PRESSURE; CONSTANT;
D O I
10.1111/j.1365-2869.2010.00846.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Auto-adjusting positive airway pressure (APAP) devices are being increasingly used to treat obstructive sleep apnoea (OSA). Anecdotal encounters of obese patients requiring high therapeutic pressure whose OSA was inadequately controlled by APAP led to this study aiming to compare the effectiveness of continuous positive airway pressure (CPAP) and APAP (S8 Autoset II (R), ResMed, NSW, Australia) in a randomised, single-blinded crossover trial. Twelve morbidly obese patients with severe OSA [mean +/- SD apnoea-hypopnoea index (AHI) 75.8 +/- 32.7, body mass index 49.9 +/- 5.2 kg m(-2), mean pressure 16.4 cmH(2)O] were consecutively recruited, and received CPAP or APAP in random order for six nights at home, separated by a four-night washout. Polysomnographic (PSG) indices of OSA were recorded at baseline and following each treatment arm. Both therapies substantially reduced the AHI (APAP 9.8 +/- 9.5 and CPAP 7.3 +/- 6.6 events h(-1); P = 0.35), but residual PSG measures of disease (AHI > 5) were common. APAP delivered a significantly lower 95th percentile pressure averaged over the home-use arm than CPAP (14.2 +/- 2.7 and 16.1 +/- 1.8 cmH(2)O, respectively, P = 0.02). The machine-scored AHI significantly overestimated the level of residual disease compared with the laboratory-scored AHI (using Chicago criteria); however, when the machine-scored AHI was <= 5 and <= 10 this was always confirmed by the PSG data. In morbidly obese OSA patients without significant co-morbid disease requiring high therapeutic pressure, our data provide support for the use of either APAP or manually titrated CPAP. We recommend objective assessment by sleep study if the S8 Autoset II indicates a high level of residual disease.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 30 条
  • [1] Auto-titrating versus standard continuous positive airway pressure for the treatment of obstructive sleep apnea: Results of a meta-analysis
    Ayas, NT
    Patel, SR
    Malhotra, A
    Schulzer, M
    Malhotra, M
    Jung, D
    Fleetham, J
    White, DP
    [J]. SLEEP, 2004, 27 (02) : 249 - 253
  • [2] Berry RB, 2002, SLEEP, V25, P148
  • [3] BONNET MH, 1992, SLEEP, V15, P526
  • [4] Effect of continuous positive airway pressure on ambulatory BP in patients with sleep apnea and hypertension - A placebo-controlled trial
    Campos-Rodriguez, Francisco
    Grilo-Reina, Antonio
    Perez-Ronchel, Jose
    Merino-Sanchez, Mercedes
    Gonzalez-Benitez, Maria A.
    Beltran-Robles, Manuel
    Almeida-Gonzalez, Carmen
    [J]. CHEST, 2006, 129 (06) : 1459 - 1467
  • [5] Constant vs automatic continuous positive airway pressure therapy - Home evaluation
    d'Ortho, MP
    Grillier-Lanoir, V
    Levy, P
    Goldenberg, F
    Corriger, E
    Harf, A
    Lofaso, F
    [J]. CHEST, 2000, 118 (04) : 1010 - 1017
  • [6] Randomized placebo-controlled trial of continuous positive airway pressure on blood pressure in the sleep apnea-hypopnea syndrome
    Faccenda, JF
    MacKay, TW
    Boon, NA
    Douglas, NJ
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (02) : 344 - 348
  • [7] Field A., 2018, Discovering statistics using R
  • [8] Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research
    Flemons, WW
    Buysse, D
    Redline, S
    Pack, A
    Strohl, K
    Wheatley, J
    Young, T
    Douglas, N
    Levy, P
    McNicholas, W
    Fleetham, J
    White, D
    Schmidt-Nowarra, W
    Carley, D
    Romaniuk, J
    [J]. SLEEP, 1999, 22 (05) : 667 - 689
  • [9] Nasal CPAP reduces systemic blood pressure in patients with obstructive sleep apnoea and mild sleepiness
    Hui, D. S.
    To, K. W.
    Ko, F. W.
    Fok, J. P.
    Chan, M. C.
    Ngai, J. C.
    Tung, A. H.
    Ho, C. W.
    Tong, M. W.
    Szeto, C-C
    Yu, C-M
    [J]. THORAX, 2006, 61 (12) : 1083 - 1090
  • [10] A NEW METHOD FOR MEASURING DAYTIME SLEEPINESS - THE EPWORTH SLEEPINESS SCALE
    JOHNS, MW