Accuracy of measured activity by the dual head gamma camera

被引:0
作者
Siennicki, Jakub [1 ]
机构
[1] Univ Lodz, Dept Phys Nucl & Radiat Safety, PL-90236 Lodz, Poland
来源
NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE | 2007年 / 958卷
关键词
activity; accuracy; gamma camera; technetium; 99m;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The subject of research was investigation of the accuracy in determining the Tc-99m activity injected in a container simulating a single organ. Data acquisition as made with different width and range of energy windows described in the article. The activities of Tc-99m were determined with an error ranging from 7% to 27%. The most probable source of errors are scattered photons.
引用
收藏
页码:280 / 281
页数:2
相关论文
共 50 条
  • [1] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Mehdi Momennezhad
    Ramin Sadeghi
    Shahrokh Nasseri
    Radiological Physics and Technology, 2012, 5 (2) : 222 - 228
  • [2] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Momennezhad, Mehdi
    Sadeghi, Ramin
    Nasseri, Shahrokh
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 222 - 228
  • [3] Molecular Breast Imaging: Use of a Dual-Head Dedicated Gamma Camera to Detect Small Breast Tumors
    Hruska, Carrie B.
    Phillips, Stephen W.
    Whaley, Dana H.
    Rhodes, Deborah J.
    O'Connor, Michael K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) : 1805 - 1815
  • [4] PET imaging using a triple-head gamma camera
    Kuikka, JT
    Sohlberg, A
    Husso-Saastamoinen, M
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (05) : 328 - 331
  • [5] Comparing the Patient Experience Between a 360° γ-Camera and a Conventional Dual-Head γ-Camera
    Komber, Hend
    Little, David
    Cade, Sarah
    Graham, Richard
    Redman, Stewart
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2022, 50 (02) : 132 - 136
  • [6] Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part II. Evaluation in patients
    Hruska, Carrie B.
    Weinmann, Amanda L.
    Skjerseth, Christina M. Tello
    Wagenaar, Eric M.
    Conners, Amy L.
    Tortorelli, Cindy L.
    Maxwell, Robert W.
    Rhodes, Deborah J.
    O'Connor, Michael K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3476 - 3483
  • [7] Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms
    Hruska, Carrie B.
    Weinmann, Amanda L.
    O'Connor, Michael K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3466 - 3475
  • [8] Quantification and accuracy of activity data measured with VHF and GPS telemetry
    Coulombe, Marie-Lou
    Masse, Ariane
    Cote, Steeve D.
    WILDLIFE SOCIETY BULLETIN, 2006, 34 (01): : 81 - 92
  • [9] SPEMT imaging with a dedicated VAoR dual-head camera: preliminary results
    Camarda, M.
    Belcari, N.
    Del Guerra, A.
    Vecchio, S.
    Bennati, P.
    Cinti, M. N.
    Pani, R.
    Campanini, R.
    Iampieri, E.
    Lanconelli, N.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [10] The HICAM Gamma Camera
    Fiorini, C.
    Busca, P.
    Peloso, R.
    Abba, A.
    Geraci, A.
    Bianchi, C.
    Poli, G. L.
    Virotta, G.
    Erlandsson, K.
    Hutton, B. F.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    Pedretti, A.
    Van Mullekom, P.
    Ottobrini, L.
    Lucignani, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 537 - 544