Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis

被引:9
|
作者
Yenigun, Serdar [1 ]
Ercal, Pinar [2 ,3 ]
Ozden-Yenigun, Elif [4 ]
Bulent Katiboglu, Ahmet [5 ]
机构
[1] Private Practice, Istanbul, Turkey
[2] Queen Mary Univ London QMUL, Ctr Oral Immunobiol & Regenerat Med, London E1 2AD, England
[3] Queen Mary Univ London QMUL, Barts & London Sch Med & Dent, Inst Dent, Ctr Oral Clin Res, London E1 2AD, England
[4] Royal Coll Art, Sch Design, London, England
[5] Atlas Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Istanbul, Turkey
关键词
dental implants; finite element analysis; marginal bone loss; DENTAL IMPLANT; REMOVAL TORQUE; MORSE-TAPER; SCREW; CONNECTIONS; DIAMETER; LENGTH; RESISTANCE; RESORPTION; INTERFACE;
D O I
10.11607/jomi.8554
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to determine the effect of solid (one-piece) and two-piece abutments on the stress profile of narrow implants with marginal bone loss. Materials and Methods: Solid and two-piece abutments were connected to a conical internal octagon-connection implant (3.3 mm in diameter, 10 mm in length) and restored with a single crown. Three-dimensional finite element analysis was used to simulate the stress distribution in implant models with different levels of marginal bone resorption (0, 1, 2, and 3 mm). The effect of the design variables under increased bone resorption scenarios, including abutment screw length and diameter, was assessed. Static loading was applied to determine the mechanical response of the implant and cortical and trabecular bone. Results: Marginal bone resorption levels dominated the mechanical response under static loading conditions. A marginal bone loss of 3 mm significantly increased stress values in the implant vicinity and abutment screw. Both abutment designs displayed similar stress distribution in the surrounding bone, but lower stress values were observed in the implant body with two-piece abutments. The abutment screw length was more effective in the resultant stress, as the longer screws reduced the stress in the implants. Conclusion: Marginal bone resorption magnitude is the crucial parameter in biomechanics to determine the mechanical behavior. As bone loss increases, resultant stress around implants under mastication forces may lead to implant failure, regardless of abutment type.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 50 条
  • [41] Influence of Crown-to-Implant Ratio on Long Term Marginal Bone Loss Around Short Implants
    Di Fiore, Adolfo
    Vigolo, Paolo
    Sivolella, Stefano
    Cavallin, Francesco
    Katsoulis, Joannis
    Monaco, Carlo
    Stellini, Edoardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 992 - 998
  • [42] The influence of the distance between narrow implants and the adjacent teeth on marginal bone levels
    Galindo-Moreno, Pablo
    Padial-Molina, Miguel
    Nilsson, Peter
    King, Paul
    Worsaae, Nils
    Schramm, Alexander
    Maiorana, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (06) : 704 - 712
  • [43] Finite element analysis of narrow dental implants
    Valera-Jimenez, J. F.
    Burgueno-Barris, G.
    Gomez-Gonzalez, S.
    Lopez-Lopez, J.
    Valmaseda-Castellon, E.
    Fernandez-Aguado, E.
    DENTAL MATERIALS, 2020, 36 (07) : 927 - 935
  • [44] Tridimensional finite element analysis to detect stress distribution in implants
    Danza, M.
    Paracchini, L.
    Carinci, F.
    DENTAL CADMOS, 2012, 80 (10) : 598 - 602
  • [45] A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants
    Bergkvist, Goran
    Simonsson, Kjell
    Rydberg, Kristofer
    Johansson, Fredrik
    Derand, Tore
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (01) : 40 - 46
  • [46] Comparison of Single-Standing or Connected Implants on Stress Distribution in Bone of Mandibular Overdentures: A Two-Dimensional Finite Element Analysis
    Tabata, Lucas Fernando
    Assuncao, Wirley Goncalves
    Ricardo Barao, Valentim Adelino
    Gomes, Erica Alves
    Delben, Juliana Aparecida
    Capello de Sousa, Edson Antonio
    Rocha, Eduardo Passos
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) : 696 - 702
  • [47] Investigation of the Type of Angled Abutment for Anterior Maxillary Implants: A Finite Element Analysis
    Korkmaz, Ismail Hakki
    Kul, Esra
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : 689 - 696
  • [48] Influence of Implant Collar Design on Stress and Strain Distribution in the Crestal Compact Bone: A Three-Dimensional Finite Element Analysis
    Shen, Wan-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 901 - 910
  • [49] Influence of the modulus of elasticity of dental implants on the distribution of stresses in the alveolar bone by the finite element method: A systematic review
    Tardelli, Juliana Dias Corpa
    Alves, Bruna Monteiro de Barros Ciribelli
    Valente, Mariana Lima da Costa
    dos Reis, Andrea Candido
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2023, 35 (05) : 383 - 389
  • [50] The influence of implant body and thread design of mini dental implants on the loading of surrounding bone: a finite element analysis
    Toth, Arpad
    Hasan, Istabrak
    Bourauel, Christoph
    Mundt, Torsten
    Biffar, Reiner
    Heinemann, Friedhelm
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (04): : 393 - 405