Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis

被引:9
|
作者
Yenigun, Serdar [1 ]
Ercal, Pinar [2 ,3 ]
Ozden-Yenigun, Elif [4 ]
Bulent Katiboglu, Ahmet [5 ]
机构
[1] Private Practice, Istanbul, Turkey
[2] Queen Mary Univ London QMUL, Ctr Oral Immunobiol & Regenerat Med, London E1 2AD, England
[3] Queen Mary Univ London QMUL, Barts & London Sch Med & Dent, Inst Dent, Ctr Oral Clin Res, London E1 2AD, England
[4] Royal Coll Art, Sch Design, London, England
[5] Atlas Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Istanbul, Turkey
关键词
dental implants; finite element analysis; marginal bone loss; DENTAL IMPLANT; REMOVAL TORQUE; MORSE-TAPER; SCREW; CONNECTIONS; DIAMETER; LENGTH; RESISTANCE; RESORPTION; INTERFACE;
D O I
10.11607/jomi.8554
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to determine the effect of solid (one-piece) and two-piece abutments on the stress profile of narrow implants with marginal bone loss. Materials and Methods: Solid and two-piece abutments were connected to a conical internal octagon-connection implant (3.3 mm in diameter, 10 mm in length) and restored with a single crown. Three-dimensional finite element analysis was used to simulate the stress distribution in implant models with different levels of marginal bone resorption (0, 1, 2, and 3 mm). The effect of the design variables under increased bone resorption scenarios, including abutment screw length and diameter, was assessed. Static loading was applied to determine the mechanical response of the implant and cortical and trabecular bone. Results: Marginal bone resorption levels dominated the mechanical response under static loading conditions. A marginal bone loss of 3 mm significantly increased stress values in the implant vicinity and abutment screw. Both abutment designs displayed similar stress distribution in the surrounding bone, but lower stress values were observed in the implant body with two-piece abutments. The abutment screw length was more effective in the resultant stress, as the longer screws reduced the stress in the implants. Conclusion: Marginal bone resorption magnitude is the crucial parameter in biomechanics to determine the mechanical behavior. As bone loss increases, resultant stress around implants under mastication forces may lead to implant failure, regardless of abutment type.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 50 条
  • [31] Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    Stegaroiu, R
    Sato, T
    Kusakari, H
    Miyakawa, O
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 82 - 90
  • [32] Micromotion and Stress Distribution of Immediate Loaded Implants: A Finite Element Analysis
    Fazel, A.
    Aalai, S.
    Rismanchian, M.
    Sadr-Eshkevari, P.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) : 267 - 271
  • [33] Effects of the Implant Design on Peri-Implant Bone Stress and Abutment Micromovement: Three-Dimensional Finite Element Analysis of Original Computer-Aided Design Models
    Yamanishi, Yasufumi
    Yamaguchi, Satoshi
    Imazato, Satoshi
    Nakano, Tamaki
    Yatani, Hirofumi
    JOURNAL OF PERIODONTOLOGY, 2014, 85 (09) : E333 - E338
  • [34] Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis
    Nie, Huimin
    Tang, Yantai
    Yang, Yan
    Wu, Weijie
    Zhou, Wenjuan
    Liu, Zhonghao
    BMC ORAL HEALTH, 2023, 23 (01)
  • [35] Influence of connection design and material properties on stress distribution and fatigue lifetime of zygomatic implants: A finite element analysis
    Alberto, Laura H. J.
    Alamgir, Saadman
    Griggs, Jason A.
    Roach, Michael D.
    Williamson, Randal S.
    Chandran, Ravi
    Priddy, Matthew W.
    Lu, Yuefeng J.
    Bergin, Patrick F.
    Duan, Yuanyuan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 160
  • [36] Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis
    Arinc, Hakan
    MEDICAL SCIENCE MONITOR, 2018, 24 : 4279 - 4287
  • [37] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [38] Influence of Geometric Design Variable and Bone Quality on Stress Distribution for Zirconia Dental Implants-A 3D Finite Element Analysis
    Velmurugan, Duraisamy
    Alphin, Masilamany Santha
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2018, 117 (02): : 125 - 141
  • [39] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876
  • [40] Effect of microthread design of dental implants on stress and strain patterns: a three-dimensional finite element analysis
    Amid, Reza
    Raoofi, Saeed
    Kadkhodazadeh, Mahdi
    Movahhedi, Mohammad Reza
    Khademi, Maryam
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (05): : 457 - 467