19F Magnetic Resonance Imaging Signals from Peptide Amphiphile Nanostructures Are Strongly Affected by Their Shape

被引:46
|
作者
Preslar, Adam T. [1 ,2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Tantakitti, Faifan [1 ,2 ,3 ,4 ,5 ]
Park, Kitae [1 ,6 ,7 ,8 ]
Zhang, Shanrong [9 ]
Stupp, Samuel L. [1 ,2 ,3 ,4 ,5 ]
Meade, Thomas J. [1 ,6 ,7 ,8 ]
机构
[1] Northwestern Univ, Dept Chem, 2145 Sheridan Rd, Evanston, IL 60208 USA
[2] Northwestern Univ, Dept Mat Sci & Engn, Evanston, IL 60208 USA
[3] Northwestern Univ, Dept Med, Evanston, IL 60208 USA
[4] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[5] Northwestern Univ, Simpson Querrey Inst BioNanotechnol, Evanston, IL 60208 USA
[6] Northwestern Univ, Dept Mol Biosci, Evanston, IL 60208 USA
[7] Northwestern Univ, Dept Neurobiol, Evanston, IL 60208 USA
[8] Northwestern Univ, Dept Radiol, Evanston, IL 60208 USA
[9] Univ Texas Southwestern Med Ctr, Adv Imaging Res Ctr, Dallas, TX 75390 USA
基金
美国国家卫生研究院;
关键词
fluorine; magnetic resonance imaging (MRI); peptide amphiphile; fluorous; pH response; nanofiber; self-assembly; CONTRAST AGENT; PROTEIN-DETECTION; MOLECULAR PROBE; MRI; PH; NANOPROBES; RELEASE; DESIGN; TUMOR; NANOFIBERS;
D O I
10.1021/acsnano.6b00267
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Magnetic resonance imaging (MRI) is a noninvasive imaging modality that provides excellent spatial and temporal resolution. The most commonly used MR probes face significant challenges originating from the endogenous H-1 background signal of water. In contrast, fluorine MRI (F-19 MRI) allows quantitative probe imaging with zero background signal. Probes with high fluorine content are required for high sensitivity, suggesting nanoscale supramolecular assemblies containing F-19 probes offer a potentially useful strategy for optimum imaging as a result of improved payload. We report here on supramolecular nanostructures formed by fluorinated peptide amphiphiles containing either glutamic acid or lysine residues in their sequence. We identified molecules that form aggregates in water which transition from cylindrical to ribbon-like shape as pH increased from 4.5 to 8.0. Interestingly, we found that ribbon-like nanostructures had reduced magnetic resonance signal, whereas their cylindrical counterparts exhibited strong signals. We attribute this drastic difference to the greater mobility of fluorinated tails in the hydrophobic compartment of cylindrical nanostructures compared to lower mobility in ribbon-like assemblies. This discovery identifies a strategy to design supramolecular, self-assembling contrast agents for F-19 MRI that can spatially map physiologically relevant changes in pH using changes in morphology.
引用
收藏
页码:7376 / 7384
页数:9
相关论文
共 50 条
  • [1] Small Molecule Probes for 19F Magnetic Resonance Imaging
    Li, Ao
    Luo, Xiangjie
    Chen, Dongxia
    Li, Lingxuan
    Lin, Hongyu
    Gao, Jinhao
    ANALYTICAL CHEMISTRY, 2023, 95 (01) : 70 - 82
  • [2] Calcium-Induced Morphological Transitions in Peptide Amphiphiles Detected by 19F-Magnetic Resonance Imaging
    Preslar, Adam T.
    Lilley, Laura M.
    Sato, Kohei
    Zhang, Shanrong
    Chia, Zer Keen
    Stupp, Samuel I.
    Meade, Thomas J.
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (46) : 39890 - 39894
  • [3] Sensitivity of magnetic resonance imaging based on the detection of 19F NMR signals
    Gulyaev, Mikhail V.
    Anisimov, Nikolay V.
    Ustyuzhanina, Nadezhda E.
    Dmitrenok, Andrey S.
    Shashkov, Alexander S.
    Yashunsky, Dmitry V.
    Gervits, Lev L.
    Pirogov, Yury A.
    Nifantiev, Nikolay E.
    MENDELEEV COMMUNICATIONS, 2016, 26 (01) : 24 - 25
  • [4] Fluorinated Polyurethane Scaffolds for 19F Magnetic Resonance Imaging
    Lammers, Twan
    Mertens, Marianne E.
    Schuster, Philipp
    Rahimi, Khosrow
    Shi, Yang
    Schulz, Volkmar
    Kuehne, Alexander J. C.
    Jockenhoevel, Stefan
    Kiessling, Fabian
    CHEMISTRY OF MATERIALS, 2017, 29 (07) : 2669 - 2671
  • [5] Calcium Fluoride Nanocrystals: Tracers for In Vivo 19F Magnetic Resonance Imaging
    Ashur, Idan
    Allouche-Arnon, Hyla
    Bar-Shir, Amnon
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (25) : 7478 - 7482
  • [6] 19F Magnetic Resonance Imaging and Spectroscopy in Neuroscience
    Modo, Michel
    NEUROSCIENCE, 2021, 474 : 37 - 50
  • [7] Organic Nanoprobes for Fluorescence and 19F Magnetic Resonance Dual-Modality Imaging
    Xu, Minmin
    Guo, Chang
    Hu, Gaofei
    Xu, Suying
    Wang, Leyu
    CHINESE JOURNAL OF CHEMISTRY, 2018, 36 (01) : 25 - 30
  • [8] Fluorine Labeling of Nanoparticles and In Vivo 19F Magnetic Resonance Imaging
    Manuel Arango, Juan
    Padro, Daniel
    Blanco, Jorge
    Lopez-Fernandez, Sonia
    Castellnou, Pilar
    Villa-Valverde, Palmira
    Ruiz-Cabello, Jesus
    Martin, Abraham
    Carril, Monica
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (11) : 12941 - 12949
  • [9] Superhydrophilic fluorinated polymer and nanogel for high-performance 19F magnetic resonance imaging
    Feng, Zujian
    Li, Qinghua
    Wang, Weiwei
    Ni, Qiankun
    Wang, Yufei
    Song, Huijuan
    Zhang, Chuangnian
    Kong, Deling
    Liang, Xing-Jie
    Huang, Pingsheng
    BIOMATERIALS, 2020, 256
  • [10] Hot spot 19F magnetic resonance imaging of inflammation
    Bouvain, Pascal
    Temme, Sebastian
    Floegel, Ulrich
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2020, 12 (06)