At-home end-tidal carbon dioxide measurement in children with invasive home mechanical ventilation

被引:6
|
作者
Foster, Carolyn C. [1 ,2 ,3 ]
Kwon, Soyang [2 ]
Shah, Avani, V [4 ,5 ]
Hodgson, Caroline A. [5 ]
Hird-McCorry, Lindsey P. [5 ]
Janus, Angela [5 ]
Jedraszko, Aneta M. [2 ]
Swanson, Philip [5 ]
Davis, Matthew M. [1 ,2 ,6 ,7 ,8 ]
Goodman, Denise M. [4 ,9 ]
Laguna, Theresa A. [4 ]
机构
[1] Northwestern Univ, Dept Pediat, Div Adv Gen Pediat & Primary Care, Feinberg Sch Med, 225 East Chicago Ave,Box 162, Chicago, IL 60611 USA
[2] Ann & Robert H Lurie Childrens Hosp Chicago, Mary Ann & J Milburn Smith Child Hlth Outcomes Re, Stanley Manne Childrens Res Inst, Chicago, IL 60611 USA
[3] Ann & Robert H Lurie Childrens Hosp Chicago, Digital Hlth, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Pediat, Div Pulm & Sleep Med, Feinberg Sch Med, Chicago, IL 60611 USA
[5] Ann & Robert H Lurie Childrens Hosp Chicago, Pulm Habilitat Program, Chicago, IL 60611 USA
[6] Northwestern Univ, Dept Med, Feinberg Sch Med, Chicago, IL 60611 USA
[7] Northwestern Univ, Dept Med Social Sci, Feinberg Sch Med, Chicago, IL 60611 USA
[8] Northwestern Univ, Dept Prevent Med, Feinberg Sch Med, Chicago, IL 60611 USA
[9] Northwestern Univ, Dept Pediat, Div Crit Care Med, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
carbon dioxide; children with medical complexity; home mechanical ventilation; long-term mechanical ventilation; remote patient monitoring; TRANSPORTABLE CAPNOMETER; DECANNULATION; DESIGN;
D O I
10.1002/ppul.26092
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end-tidal carbon dioxide (EtCO2) monitoring at home are limited. We hypothesized that a palm-sized, portable endotracheal capnograph (PEC) that measures EtCO2 could be adapted for in-home use in children with HMV. Methods We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back-to-back breaths by children (0-17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO2 values with concurrent mean values of in-clinic EtCO2 and transcutaneous CO2 (TCM) capnometers. The Bland-Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family-caregivers at home. Results CO2 values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in-clinic EtCO2 device was 0.85 with a mean difference of -3.8 mmHg and precision of +/- 1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of +/- 1.0. Family-caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. Conclusions A portable, noninvasive device for measuring EtCO2 was feasible and acceptable, with values that trend similarly to currently in-practice, outpatient models. These devices may facilitate monitoring of EtCO2 at home in children with invasive HMV.
引用
收藏
页码:2735 / 2744
页数:10
相关论文
共 50 条
  • [1] Arterial to end-tidal carbon dioxide difference in children undergoing mechanical ventilation of the lungs during general anaesthesia
    Onodi, C.
    Buhler, P. K.
    Thomas, J.
    Schmitz, A.
    Weiss, M.
    ANAESTHESIA, 2017, 72 (11) : 1357 - 1364
  • [2] Weaning strategies for children on home invasive mechanical ventilation
    Kamalaporn, Harutai
    Preutthipan, Aroonwan
    Coates, Allan L.
    PEDIATRIC PULMONOLOGY, 2024, 59 (08) : 2131 - 2140
  • [3] End-tidal carbon dioxide measurement and breathing system filters
    Hardman, JG
    Curran, J
    Mahajan, RP
    ANAESTHESIA, 1997, 52 (07) : 646 - 648
  • [4] END-TIDAL CARBON-DIOXIDE MEASUREMENT IN INFANTS AND CHILDREN DURING AND AFTER GENERAL-ANESTHESIA
    CAMPBELL, FA
    MCLEOD, ME
    BISSONNETTE, B
    SWARTZ, JS
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (02): : 107 - 110
  • [5] Predictors for invasive home mechanical ventilation duration in bronchopulmonary dysplasia
    Foster, Carolyn
    Noreen, Paige
    Grage, Jennifer
    Kwon, Soyang
    Hird-McCorry, Lindsey P.
    Janus, Angela
    Davis, Matthew M.
    Goodman, Denise
    Laguna, Theresa
    PEDIATRIC PULMONOLOGY, 2023, 58 (07) : 2085 - 2093
  • [6] COLORIMETRIC END-TIDAL CARBON-DIOXIDE MONITORING DURING TRANSFER OF INTUBATED CHILDREN
    HIGGINS, D
    FORREST, ETS
    LLOYDTHOMAS, A
    INTENSIVE CARE MEDICINE, 1991, 17 (01) : 63 - 64
  • [7] Identifying and managing psychosocial problems in children on home invasive mechanical ventilation
    Ozcan, Gizem
    Cobanoglu, Nazan
    PEDIATRIC PULMONOLOGY, 2024, 59 (08) : 2149 - 2152
  • [8] Arterial to end-tidal carbon dioxide tension difference in children with congenital heart disease
    Short, JA
    Paris, ST
    Booker, PD
    Fletcher, R
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (03) : 349 - 353
  • [9] Correlation of End-Tidal Carbon Dioxide with Arterial Carbon Dioxide in Mechanically Ventilated Patients
    Razi, Ebrahim
    Moosavi, Gholam Abbass
    Omidi, Keivan
    Saebi, Ashkan Khakpour
    Razi, Armin
    ARCHIVES OF TRAUMA RESEARCH, 2012, 1 (02) : 58 - 62
  • [10] End-tidal carbon dioxide levels predict cardiac arrest
    H Manyam
    P Thiagarajah
    G Patel
    R French
    M Balaan
    Critical Care, 15 (Suppl 1):