Suppression of false arrhythmia alarms in the ICU: a machine learning approach

被引:13
作者
Ansari, Sardar [1 ,2 ]
Belle, Ashwin [1 ,2 ]
Ghanbari, Hamid [2 ,3 ]
Salamango, Mark [2 ]
Najarian, Kayvan [1 ,2 ,4 ,5 ]
机构
[1] Univ Michigan, Dept Emergency Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Michigan Ctr Integrat Res Clin Care, Ann Arbor, MI USA
[3] Univ Michigan, Dept Internal Med, Ann Arbor, MI USA
[4] Univ Michigan, Dept Computat Med & Bioinformat, Ann Arbor, MI USA
[5] Univ Michigan, Dept Comp Sci, Ann Arbor, MI USA
关键词
false alarm; arrhythmia detection; Physionet; 2015; beat detection; PATIENT; FATIGUE;
D O I
10.1088/0967-3334/37/8/1186
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a novel approach for false alarm suppression using machine learning tools. It proposes a multi-modal detection algorithm to find the true beats using the information from all the available waveforms. This method uses a variety of beat detection algorithms, some of which are developed by the authors. The outputs of the beat detection algorithms are combined using a machine learning approach. For the ventricular tachycardia and ventricular fibrillation alarms, separate classification models are trained to distinguish between the normal and abnormal beats. This information, along with alarm-specific criteria, is used to decide if the alarm is false. The results indicate that the presented method was effective in suppressing false alarms when it was tested on a hidden validation dataset.
引用
收藏
页码:1186 / 1203
页数:18
相关论文
共 38 条
  • [1] Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform.
    Aboukhalil, Anton
    Nielsen, Larry
    Saeed, Mohammed
    Mark, Roger G.
    Clifford, Gari D.
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2008, 41 (03) : 442 - 451
  • [2] Ansari S, 2015, COMPUT CARDIOL CONF, V42, P1181, DOI 10.1109/CIC.2015.7411127
  • [3] Antink CH, 2015, COMPUT CARDIOL CONF, V42, P285, DOI 10.1109/CIC.2015.7408642
  • [4] Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach
    Antink, Christoph Hoog
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1679 - 1690
  • [5] Arberet S, 2013, COMPUT CARDIOL CONF, V40, P935
  • [6] Blount M., 2010, P 1 ACM INT HLTH INF, P647, DOI DOI 10.1145/1882992.1883094
  • [7] ALARM SYSTEMS
    BOVILL, JG
    [J]. BAILLIERES CLINICAL ANAESTHESIOLOGY, 1990, 4 (01): : 193 - 200
  • [8] Research : A model of clinical alarm errors in hospital
    Busch-Vishniac, Llene
    [J]. Biomedical Instrumentation and Technology, 2015, 49 (04) : 280 - 291
  • [9] Clifford GD, 2015, COMPUT CARDIOL CONF, V42, P273, DOI 10.1109/CIC.2015.7408639
  • [10] Couto P, 2015, COMPUT CARDIOL CONF, V42, P749, DOI 10.1109/CIC.2015.7411019