The effect of structural parameters of total hip arthroplasty on polyethylene liner wear behavior: A theoretical model analysis

被引:9
作者
Li, Guoan [1 ]
Peng, Yun [1 ]
Zhou, Chaochao [1 ,2 ]
Jin, Zhongmin [3 ,4 ]
Bedair, Hany [1 ,2 ]
机构
[1] Harvard Med Sch, Newton Wellesley Hosp, Orthopaed Bioengn Res Ctr, Dept Orthopaed Surg, Newton, MA USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[3] Southwest Jiaotong Univ, Sch Mech Engn, Tribol Res Inst, Chengdu, Sichuan, Peoples R China
[4] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds, W Yorkshire, England
关键词
head-polyethylene contact; polyethylene wear; THA structure; THA structural parameters; total hip arthroplasty; MOLECULAR-WEIGHT POLYETHYLENE; CROSS-LINKED POLYETHYLENE; FEMORAL-HEAD SIZE; ACETABULAR COMPONENTS; CONTACT STRESS; CUPS; SIMULATION; THICKNESS; FRICTION; REVISION;
D O I
10.1002/jor.24577
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Using large femoral heads in total hip arthroplasty (THA) has been widely advocated to improve the function and longevity of the components. However, increasing the head size has been shown to accelerate polyethylene liner wear. Few studies have investigated the effect of other important structural parameters (such as polyethylene liner thickness, metal cup size, head-liner conformity, loading conditions, etc.) on the biomechanical functions of the THAs. In this study, an analytical model was used to evaluate the polyethylene liner wear characteristics of the THAs (defined using a biomechanical wear factor) with various structural parameters of the THAs and loading conditions. For all the THA systems examined in this study, under the same loading conditions, a larger head leads to increasing contact areas, lower contact stresses, and higher biomechanical wear factors. When the head size is fixed, a decrease in the polyethylene liner thickness or a decrease in the head-liner conformity leads to higher peak contact stresses and smaller contact areas and consequently, lower biomechanical wear factors. This study provides a parametric analysis tool for the optimal design/selection of the THA systems and for prediction of early effects of various structural parameters on the biomechanical function (such as contact stresses) and longevity (such as polyethylene liner wear) of the THA systems.
引用
收藏
页码:1587 / 1595
页数:9
相关论文
共 49 条
[1]   Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants [J].
Affatato, Saverio ;
Merola, Massimiliano ;
Ruggiero, Alessandro .
MATERIALS, 2018, 11 (08)
[2]   CONTACT AND RUBBING OF FLAT SURFACES [J].
ARCHARD, JF .
JOURNAL OF APPLIED PHYSICS, 1953, 24 (08) :981-988
[3]   THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[4]  
Bates Michael D, 2015, JBJS Case Connect, V5, pe65, DOI 10.2106/JBJS.CC.N.00157
[5]   Characteristics of highly cross-linked polyethylene wear debris in vivo [J].
Baxter, Ryan M. ;
MacDonald, Daniel W. ;
Kurtz, Steven M. ;
Steinbeck, Marla J. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) :467-475
[6]   Finite element simulation of early creep and wear in total hip arthroplasty [J].
Bevill, SL ;
Bevill, GR ;
Penmetsa, JR ;
Petrella, AJ ;
Rullkoetter, PJ .
JOURNAL OF BIOMECHANICS, 2005, 38 (12) :2365-2374
[7]   Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36-vs 28-mm femoral heads [J].
Bragdon, Charles R. ;
Greene, Meridith E. ;
Freiberg, Andrew A. ;
Harris, William H. ;
Malchau, Henrik .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :125-129
[8]  
Brazier Brett G, 2018, Arthroplast Today, V4, P287, DOI 10.1016/j.artd.2018.02.001
[9]  
Cross Michael B, 2012, HSS J, V8, P270, DOI 10.1007/s11420-012-9287-7
[10]   Patient-specific hip geometry has greater effect on THA wear than femoral head size [J].
Daniel, Matej ;
Rijavec, Boris ;
Dolinar, Drago ;
Pokorny, David ;
Iglic, Ales ;
Kralj-Iglic, Veronika .
JOURNAL OF BIOMECHANICS, 2016, 49 (16) :3996-4001