The use of recycled metal in dentistry: Evaluation of mechanical properties of titanium waste recasting

被引:15
作者
Bauer, Jose [1 ]
Cella, Suelen [2 ]
Pinto, Marcelo M. [2 ]
Costa, Jose Ferreira [1 ]
Reis, Alessandra [3 ]
Loguercio, Alessandro D. [3 ]
机构
[1] Univ Fed Maranhao, Sch Dent, Dept Dent 1, BR-65085680 Sao Luis, MA, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Dent Mat, BR-05508900 Sao Paulo, Brazil
[3] Univ Estadual Ponta Grossa, Dept Restorat Dent, BR-84030900 Ponta Grossa, PR, Brazil
基金
巴西圣保罗研究基金会;
关键词
Titanium; Mechanical characterization; Recasting; Recycle; Scraps; MARGINAL ACCURACY; PORCELAIN; ALLOYS; CROWNS;
D O I
10.1016/j.resconrec.2010.05.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Environmental concerns are increasing rapidly, and the public and industry are concerned about natural resources. The products are produced to meet the customer's demand as to quality. However, today it is equally important to take into account cost, ecological factors in production and recycling of products. The same way, the dentistry must contribution with a recasting the alloys used to rehabilitation oral. This study evaluated the effect of the condition of Ti (as-received and re-cast) on its mechanical properties, microstructure and fractography. Castings (n = 6) with Ti in the as-received and once recast condition were made in a centrifugal casting machine using a high-purity argon gas. The ultimate tensile strength (UTS), proportional limit (PL) and elongation (EL) of the as-received specimens were evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The fractured specimens were polished down for Vicker's microhardness (VHN) measurement (100 g/15 s) from 25 mu m below the cast surface, then at depths of 50, 100,200 and 500 mu m. The microstructures of the alloys were also revealed. Scanning electron microscopy fractography was undertaken for the fractured surfaces after testing. The data from the mechanical tests and hardness were subjected to the Student's t-test and two-way repeated measures ANOVA, respectively. Tukey's test was used for pairwise comparison (alpha = 0.05). Higher UTS, PL and VHN and lower EL were observed for recast cp Ti. The microstructure was not influenced by recasting, but the mode of fracture was. The use of the recasting procedure can lower the costs of cp Ti castings and can be safely in dentistry. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1312 / 1316
页数:5
相关论文
共 32 条
[1]  
Anusavice K J., 1996, Philips Science of dental materials, V10th
[2]   Mechanical properties of cast Ti-6Al-4V-XCu alloys [J].
Aoki, T ;
Okafor, ICI ;
Watanabe, I ;
Hattori, M ;
Oda, Y ;
Okabe, T .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (11) :1109-1114
[3]   CASTABILITY OF CROWN AND BRIDGE ALLOYS [J].
ASGAR, K ;
ARFAEI, AH .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (01) :60-63
[4]   Compositional stability and marginal accuracy of complete cast crowns made with as-received and recast type III gold alloy [J].
Ayad, MR .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02) :162-166
[5]   Metals recycling: economic and environmental implications [J].
Ayres, RU .
RESOURCES CONSERVATION AND RECYCLING, 1997, 21 (03) :145-173
[6]   In vitro corrosion resistance of titanium made using different fabrication methods [J].
Cai, Z ;
Nakajima, H ;
Woldu, M ;
Berglund, A ;
Bergman, M ;
Okabe, T .
BIOMATERIALS, 1999, 20 (02) :183-190
[7]  
Chan DCN, 1998, J ORAL REHABIL, V25, P424
[8]  
Collings E.W., 1984, ASM HDB, P3
[9]  
Donachie M.J., 1988, Titanium : a technical guide
[10]  
GAMBOGI J, 2002, RECYCLING METALS US