Pulsed Field Ablation of Superior Vena Cava: Feasibility and Safety of Pulsed Field Ablation

被引:14
|
作者
Zhu, Tongjian [1 ]
Wang, Zhen [1 ]
Wang, Songyun [1 ]
Shi, Tiancai [2 ]
Zhu, Xiaolin [2 ]
Ma, Kezhong [3 ]
Wang, Zhuo [1 ]
Gao, Jinnian [2 ]
Jiang, Hong [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Cardiol, Wuhan, Peoples R China
[2] Sichuan Jinjiang Elect Technol Co Ltd, Chengdu, Sichuan, Peoples R China
[3] Hubei Univ Arts & Sci, Affiliated Hosp, Xiangyang Cent Hosp, Dept Cardiol, Xiangyang, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2021年 / 8卷
基金
中国国家自然科学基金;
关键词
pulsed field ablation; superior vena cava; arrhythmias; phrenic palsy; sinus node injury; ATRIAL-FIBRILLATION; CATHETER ABLATION; ELECTRICAL ISOLATION; INJURY;
D O I
10.3389/fcvm.2021.698716
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Studies have shown that pulsed field ablation (PFA) has excellent effectiveness and safety in pulmonary vein isolation (PVI). However, there are few reports about the application of PFA, especially the alternating current (AC) biphase PFA, in superior vena cava (SVC) isolation, and its effectiveness and safety are still unclear. Objective: To investigate the efficacy and safety of the AC biphase PFA for SVC isolation, and to provide evidence for the clinical use of PFA for SVC. Methods: Eight pigs and two dogs were included in the study. PFA was delivered to these pigs and dogs. Pacing threshold and electrogram data were recorded before and after PFA. Voltage mapping of SCV was obtained before, after, and 3 weeks after PFA. At the end, all animals were euthanatized for gross pathology analysis. Results: For eight pigs, the median pacing threshold was 1.5 (1.4, 2.75) mA before PFA, while > 6.0 mA after PFA for all animals. The average electrogram amplitude reduction was 61.33 +/- 24.90% for ablations with the initial amplitude >= 0.5 mv. For two dogs, pacing threshold change and electrogram amplitude reduction were also observed. No phrenic palsy or sinus node injury was observed during PFA in any animal. Furthermore, voltage mapping showed that the voltage amplitude was significantly decreased in all animals and this could be kept for more than 3 weeks. Moreover, transmural tissue damage with reserved vessel and nerve were shown, no SVC stenosis was found at 3 weeks after PFA. Conclusion: PFA can effectively isolate SVC. Transmural tissue damage of SVC can be achieved without phrenic palsy, sinus node injury nor SVC stenosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Pulsed Field Ablation of Atrial Fibrillation: A Comprehensive Review
    Matos, Carlos D.
    Hoyos, Carolina
    Miranda-Arboleda, Andres F.
    Diaz, Juan C.
    Hincapie, Daniela
    Patino, Carlos
    Hernadez, Ricardo H.
    Zei, Paul C.
    Romero, Jorge E.
    Osorio, Jose
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (11)
  • [32] Comparative Efficacy and Safety of Pulsed Field Ablation Versus Radiofrequency Ablation of Idiopathic LV Arrhythmias
    Younis, Arwa
    Tabaja, Chadi
    Kleve, Ryan
    Garrott, Kara
    Lehn, Lauren
    Buck, Eric
    Hussein, Ayman A.
    Nakhla, Shady
    Nakagawa, Hiroshi
    Krywanczyk, Alison
    Taigen, Tyler
    Kanj, Mohamed
    Sroubek, Jakub
    Saliba, Walid I.
    Wazni, Oussama M.
    Santangeli, Pasquale
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (09) : 1998 - 2009
  • [33] Pulsed Field Ablation: a New Paradigm for Catheter Ablation of Arrhythmias
    Maan, Abhishek
    Koruth, Jacob
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (02) : 103 - 108
  • [34] Initial experience with pulsed field ablation for atrial fibrillation
    Magni, Federico. T. T.
    Mulder, Bart. A. A.
    Groenveld, Hessel. F. F.
    Wiesfeld, Ans C. P.
    Tieleman, Robert. G. G.
    Cox, Moniek. G. G.
    Van Gelder, Isabelle. C. C.
    Smilde, Tom
    Tan, Eng. S. S.
    Rienstra, Michiel
    Blaauw, Yuri
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [35] Superior vena cava flutter: Electrophysiology and ablation
    Merino, JL
    Peinado, R
    Abello, M
    Gnoatto, M
    Vasserot, MG
    Sobrino, JA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) : 568 - 575
  • [36] Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation
    Fueting, Anna
    Reinsch, Nico
    Brokkaar, Lenny
    Hartl, Stefan
    Hoewel, Dennis
    Essling, Anika
    Bell, John
    Rausch, Eva
    Neven, Kars
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (04) : E011547
  • [37] Efficacy and Safety of Pulsed Field Ablation in Atrial Fibrillation: A Systematic Review
    Shtembari, Jurgen
    Shrestha, Dhan Bahadur
    Pathak, Bishnu Deep
    Dhakal, Bishal
    Regmi, Binit Upadhaya
    Patel, Nimesh K. K.
    Shantha, Ghanshyam Palamaner Subash
    Kalahasty, Gautham
    Kaszala, Karoly
    Koneru, Jayanthi N. N.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [38] Workflow of the zero-fluoro pulsed field ablation
    Hirata, Shu
    Nagashima, Koichi
    Watanabe, Ryuta
    Wakamatsu, Yuji
    Hirata, Moyuru
    Kurokawa, Sayaka
    Otsuka, Naoto
    Sawada, Masanaru
    Okumura, Yasuo
    JOURNAL OF ARRHYTHMIA, 2024, 40 (06) : 1529 - 1532
  • [39] Pulsed field ablation for pulmonary vein isolation in the treatment of atrial fibrillation
    Bradley, Christopher J.
    Haines, David E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2136 - 2147
  • [40] Pulsed field catheter ablation in atrial fibrillation
    Di Biase, Luigi
    Diaz, Juan Carlos
    Zhang, Xiao-Dong
    Romero, Jorge
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (06) : 378 - 387