Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment

被引:190
|
作者
Wilkoff, Bruce L. [1 ]
Bello, David [2 ]
Taborsky, Milos [3 ]
Vymazal, Josef [3 ]
Kanal, Emanuel [4 ]
Heuer, Hubertus [5 ]
Hecking, Katrin [5 ]
Ben Johnson, W. [6 ]
Young, William [6 ]
Ramza, Brian [7 ]
Akhtar, Naveed [7 ]
Kuepper, Bernhard [8 ]
Hunold, Peter [8 ]
Luechinger, Roger [9 ,10 ]
Puererfellner, Helmut [11 ]
Duru, Firat [12 ]
Gotte, M. J. W. [13 ]
Sutton, Richard [14 ]
Sommer, Torsten [15 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Orlando Reg Med Ctr Inc, Orlando, FL USA
[3] Na Homoice Hosp, Prague, Czech Republic
[4] UPMC Presbyterian, Pittsburgh, PA USA
[5] St Johannes Hosp, Dortmund, Germany
[6] Mercy Hosp, Iowa Heart Ctr PC, Des Moines, IA USA
[7] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[8] Elisabeth Hosp, Essen, Germany
[9] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[10] ETH, Zurich, Switzerland
[11] Ao Krankenhaus Elisabethinen, Linz, Austria
[12] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[13] HAGA Ziekenhuis, Locatie Leyweg, Den Haag, Netherlands
[14] St Marys Hosp, London, England
[15] Univ Bonn, Acad Hosp, German Red Cross Hosp DRK Neuwied, Neuwied, Germany
关键词
Bradycardia pacing; CapSureFixMRI; EnRhythmMRI; MRI; Pacemaker; RevoMRI; Safety; SureScan; RADIOFREQUENCY POWER DEPOSITION; CARDIAC-PACEMAKERS; IN-VITRO; COMPLICATIONS; IMPLANTATION; TESLA; LEADS; SAFE;
D O I
10.1016/j.hrthm.2010.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Magnetic resonance imaging (MRI) of pacemaker patients is contraindicated due to documented potential risks to the patient from hazardous interactions between the MRI and pacemaker system. OBJECTIVE The purpose of this prospective, randomized, controlled, worldwide clinical trial was to evaluate the safety and effectiveness of a pacemaker system designed for safe use in MRI for any bradycardia indicated patient. METHODS Patients (n = 464) were randomized to undergo an MRI scan between 9 and 12 weeks postimplant (MRI group, n = 258) or not to undergo MRI (control group, n = 206) after successful implantation of the specially designed dual`-chamber pacemaker and leads. Patients were monitored for arrhythmias, symptoms, and pacemaker system function during 14 nonclinically indicated relevant brain and lumbar MRI sequences. Sequences were performed at 1.5 T and included scans with high radiofrequency power deposition and/or high gradient dB/dt exposure. Clinical evaluation of the pacemaker system function occurred immediately before and after MRI, 1 week and 1 month post`-MRI, and at corresponding times for the control group. Primary endpoints for safety analyzed the MRI procedure complication-free rate and for effectiveness compared capture and sensing performance between MRI and control groups. RESULTS No MRI-related complications occurred during or after MRI, including sustained ventricular arrhythmias, pacemaker inhibition or output failures, electrical resets, or other pacemaker malfunctions. Pacing capture threshold and sensed electrogram amplitude changes were minimal and similar between study groups. CONCLUSION This trial documented the ability of this pacemaker system to be exposed in a controlled fashion to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [1] Image Quality of Cardiac Magnetic Resonance Imaging in Patients With an Implantable Cardioverter Defibrillator System Designed for the Magnetic Resonance Imaging Environment
    Schwitter, Juerg
    Gold, Michael R.
    Al Fagih, Ahmed
    Lee, Sung
    Peterson, Michael
    Ciuffo, Allen
    Zhang, Yan
    Kristiansen, Nina
    Kanal, Emanuel
    Sommer, Torsten
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (05)
  • [2] Safety evaluation of a leadless transcatheter pacemaker for magnetic resonance imaging use
    Soejima, Kyoko
    Edmonson, Jonathan
    Ellingson, Michael L.
    Herberg, Ben
    Wiklund, Craig
    Zhao, Jing
    HEART RHYTHM, 2016, 13 (10) : 2056 - 2063
  • [3] Low-field magnetic resonance imaging: increased safety for pacemaker patients?
    Strach, Katharina
    Naehle, Claas Philip
    Muehlsteffen, Artur
    Hinz, Michael
    Bernstein, Adam
    Thomas, Daniel
    Linhart, Markus
    Meyer, Carsten
    Bitaraf, Sascha
    Schild, Hans
    Sommer, Torsten
    EUROPACE, 2010, 12 (07): : 952 - 960
  • [4] Magnetic resonance imaging interactions with a sacral neuromodulation system
    Huang, Xuechen
    Jiang, Guangqiang
    NEUROUROLOGY AND URODYNAMICS, 2021, 40 (08) : 1862 - 1868
  • [5] Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?
    Nordbeck, Peter
    Ertl, Georg
    Ritter, Oliver
    EUROPEAN HEART JOURNAL, 2015, 36 (24) : 1505 - U81
  • [6] Magnetic Resonance Imaging in Patients with Implanted Devices
    Beinart, Roy
    Nazarian, Saman
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (09) : 1040 - 1042
  • [7] Magnetic resonance imaging in patients with cardiac implanted electronic devices: focus on contraindications to magnetic resonance imaging protocols
    Horwood, Laura
    Attili, Anil
    Luba, Frank
    Ibrahim, El-Sayed H.
    Parmar, Hemant
    Stojanovska, Jadranka
    Gadoth-Goodman, Sharon
    Fette, Carey
    Oral, Hakan
    Bogun, Frank
    EUROPACE, 2017, 19 (05): : 812 - 817
  • [8] Strategies for the safe magnetic resonance imaging of pacemaker-dependent patients
    Gimbel, JR
    Bailey, SM
    Tchou, PJ
    Ruggieri, PM
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (10): : 1041 - 1046
  • [9] Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review
    Martins, R. -P.
    Baruteau, A. -E.
    Treguer, F.
    Cesari, O.
    Carsin-Nicol, B.
    Langella, B.
    Leclercq, C.
    Daubert, J. -C.
    Mabo, P.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2010, 59 (04): : 221 - 228
  • [10] Safety Aspects of Magnetic Resonance Imaging for Pacemaker Holders
    Bernardi, P.
    Cavagnaro, M.
    Pisa, S.
    Piuzzi, E.
    ICEAA: 2009 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS, VOLS 1 AND 2, 2009, : 869 - 872