Potentiometric response of calix[4]pyrrole liquid membrane electrode towards neutral nitrophenols

被引:0
|
作者
Piotrowski, T
Radecka, H
Radecki, J
Depraetere, S
Dehaen, W
机构
[1] Polish Acad Sci, Inst Anim Reprod & Food Res, Div Food Sci, PL-10747 Olsztyn, Poland
[2] Katholieke Univ Leuven, Dept Chem, B-3001 Heverlee, Leuven, Belgium
关键词
potentiometric sensor; calix[4]pyrroles; neutral nitrophenols; proton affinity;
D O I
10.1002/1521-4109(200103)13:4<342::AID-ELAN342>3.3.CO;2-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calix[4]pyrroles were applied as a new class of ligands of potentiometric sensors for neutral nitrophenol isomers. Calix[4]pyrrole-containing liquid membranes exhibit a very high affinity to proton uptake. These membranes, in protonated form, showed very high selectivity towards para-nitrophenol in the presence of other nitrophenols and dihydroxybenzene isomers. The probable mechanism of the potentiometric signal generation of the membrane investigated upon stimulation by nitrophenol isomers existing in neutral form is discussed.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] Potentiometric response of amino-calix[4]resorcinarenes modified membranes towards neutral nitrophenols
    Ocicka, K
    Radecka, H
    Radecki, J
    Pietraszkiewicz, M
    Pietraszkiewicz, O
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03): : 217 - 224
  • [2] Effect of the symmetry of the calix[4]pyrrole cavity on sensitivity and selectivity of potentiometric sensors for neutral nitrophenols
    Piotrowski, T
    Radecka, H
    Radecki, J
    Depraetere, S
    Dehaen, W
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2001, 18 (1-2): : 223 - 228
  • [3] Potentiometric response of liquid membrane electrode incorporated with macrocyclic polyamine towards benzoate
    Bulgariu, L
    Radecka, H
    Pietraszkiewiez, M
    Pietraszkiewicz, O
    ANALYTICAL LETTERS, 2003, 36 (07) : 1325 - 1334
  • [4] Potentiometric discrimination of fluoro- and chlorophenol isomers based on the host functionality of calix[4]pyrrole at liquid membrane surfaces
    Piotrowski, T
    Radecka, H
    Radecki, J
    Depraetere, S
    Dehaen, W
    ANALYTICAL LETTERS, 2002, 35 (12) : 1895 - 1906
  • [5] Interface host-guest interaction between calix[4]pyrrole and neutral derivatives of phenol as the base for their potentiometric discrimination
    Radecki, J
    Radecka, H
    Piotrowski, T
    Depraetere, S
    Dehaen, W
    Plavec, J
    ELECTROANALYSIS, 2004, 16 (24) : 2073 - 2081
  • [6] Potentiometric liquid membrane pH sensors based on calix[4]-aza-crowns
    Liu, Xiao-He
    Peng, Bo
    Liu, Fang
    Qin, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 125 (02) : 656 - 663
  • [7] ANOMALOUS RESPONSE OF LIQUID MEMBRANE ELECTRODE BASED ON NEUTRAL CARRIER
    SETO, H
    JYO, A
    ISHIBASHI, N
    CHEMISTRY LETTERS, 1975, (05) : 483 - 486
  • [8] POTENTIOMETRIC DISCRIMINATION OF ORGANIC AMINES BY A LIQUID MEMBRANE-ELECTRODE BASED ON A LIPOPHILIC HEXAESTER OF CALIX[6]ARENE
    ODASHIMA, K
    YAGI, K
    TOHDA, K
    UMEZAWA, Y
    ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1074 - 1083
  • [9] Corroles as receptors in liquid membrane electrodes and their potentiometric response towards salicylic acid
    Radecki, J
    Wona, STA
    Eddy, DB
    Dehaen, W
    ELECTROCHIMICA ACTA, 2006, 51 (11) : 2282 - 2288
  • [10] Potentiometric cholinesterase biosensor with a membrane modified with calix[4]resorcinolarene
    Evtyugin, GA
    Muslinkina, LA
    Budnikov, GK
    Kazakova, EK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (04) : 367 - 371